TB-3078

 Page 5 of 6

© 2019 DESCO INDUSTRIES INC

Employee Owned

3.5 megohms

1.  If the desired resistance is 3.5M, jumpers JP1 (MAT 

1 and JP2 (MAT 2) need to be on one pin (see 

Figure 5). 

2.  The respective potentiometers need to be adjusted 

fully clockwise. The pots are located inside the unit 

on the bottom board (see Figure 6).

High Resistance (10 kilohms to 3.5 megohms)

1.  If the desired resistance is 10k - 3.5M, jumpers JP1 

(MAT 1) and JP2 (MAT 2) need to be on one pin 

(see Figure 5). 

2.  Use a resistor decade box to set the desired 

resistance between the ground terminal and ground. 

3.  Connect the mat wire to the decade box and 

connect the decade box to ground. 

4.  Turn the appropriate potentiometer 

counter-clockwise until the GROUND LED 

illuminates red and alarm sounds (see Figure 6). 

5.  Slowly turn the potentiometer clockwise until the 

GROUND LED illuminates green. 

6.  Add 10% more resistance (at least 1 ohm) to the 

decade box and verify that the GROUND LED 

illuminates red and alarm sounds. 

7.  Return back to the starting resistance and confirm 

that the green LED illuminates again. Repeat steps 

4-7 if the  monitor does not fail with the increased 

resistance or return to a pass condition.

Low Resistance (<1 kilohm)

1.  If the desired resistance is < 1k, jumpers JP1 (MAT 

1) and JP2 (MAT 2) need to be on both pins (see 

Figure 5). 

2.  Use a resistor decade box to set the desired 

resistance between the ground terminal and ground. 

3.  Connect the mat wire to the decade box and 

connect the decade box to ground. 

4.  Turn the appropriate potentiometer 

counter-clockwise until the GROUND LED 

illuminates red and alarm sounds (see Figure 6). 

5.  Slowly turn the potentiometer clockwise until the 

GROUND LED illuminates green. 

6.  Add 10% more resistance (at least 1 ohm) to the 

decade box and verify that the GROUND LED 

illuminates red and alarm sounds. 

7.  Return back to the starting resistance and confirm 

that the green LED illuminates again. Repeat steps 

4-7 if the  monitor does not fail with the increased 

resistance or return to a pass condition.

Calibration

Frequency of recalibration should be based on the 

critical nature of those ESD sensitive items handled 

and the risk of failure for the ESD protective equipment 

and materials. In general, Desco recommends that 

calibration be performed annually.
Use the EMIT 

50524

 Limit Comparator to perform 

periodic verification (once every 6-12 months) of the 

Zero Volt Monitor Monitor. The verification tester can 

be used to check the test limits of the Zero Volt Monitor 

without removing it from the workstation.
See 

TB-6542

 for more information.

Figure 7. EMIT 50524 Limit Comparator

Summary of Contents for 19668

Page 1: ...posite conductor Desco Zero Volt Monitors determine that the operator s path to ground is between the 2 megohms lower limit and 10 megohms upper limit Additionally the Desco Zero Volt Monitor determines if voltage greater than 1 25 V has accumulated on the operator March 2019 ANSI ESD S20 20 section 7 3 states Compliance verification records shall be established and maintained to provide evidence ...

Page 2: ... plate screw of a grounded AC wall outlet may provide a convenient connection point 6 Route the mat cords from the back of the monitor to the snaps on worksurface mats The white cord is for worksurface mat 1 The black cord is for worksurface mat 2 7 Insert the operator remote cables into their appropriate jacks located at the back of the monitor The white cable is for operator 1 The black cable is...

Page 3: ...IES INC Employee Owned Figure 3 Installing the Zero Volt Monitor OPERATOR 2 REMOTE JACK OPERATOR 1 REMOTE JACK MAT 2 CORD MAT 1 CORD MONITOR GROUND CORD 10mm PUSH CLINCH SNAPS 10mm PUSH CLINCH SNAPS WORKSURFACE 2 10mm snaps need to pierce and clinch bottom side of mat and be 12 72 apart 10mm snaps need to pierce and clinch bottom side of mat and be 12 72 apart WORKSURFACE 1 ...

Page 4: ... the wristband to ensure that it fits securely If you have dry skin apply an approved dissipative hand lotion such as Menda Reztore ESD Hand Lotion 5 The AUX MAT jack located on the operator remote is a grounded and unmonitored connection for guests or supervisors It is intended to be used with a single wire wrist strap Maintenance JUMPER CONFIGURATIONS Jumper Jumper Position Setting JP5 Off Audib...

Page 5: ...ncreased resistance or return to a pass condition Low Resistance 1 kilohm 1 If the desired resistance is 1k jumpers JP1 MAT 1 and JP2 MAT 2 need to be on both pins see Figure 5 2 Use a resistor decade box to set the desired resistance between the ground terminal and ground 3 Connect the mat wire to the decade box and connect the decade box to ground 4 Turn the appropriate potentiometer counter clo...

Page 6: ...ight 1 6 lbs 0 7 kg Operator Test Limts 1 91 megohms to 10 megohms 10 Worksurface Test Limit 3 5 megohms 10 Charge Detect Test Limit 1 25 VDC Operator Test Voltage 1 25 V open circuit Worksurface Test Voltage 200 mV open circuit Country of Origin United States of America The worksurface mat must have a conductive layer such as Dual Layer Rubber or Dissipative 3 Layer Vinyl with conductive buried l...

Reviews: