![Desco 19668 Installation, Operation And Maintenance Manual Download Page 4](http://html1.mh-extra.com/html/desco/19668/19668_installation-operation-and-maintenance-manual_2486633004.webp)
DESCO WEST
- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178
DESCO EAST
- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website:
Desco.com
TB-3078
Page 4 of 6
© 2019 DESCO INDUSTRIES INC
Employee Owned
Operation
1. Fit the wristband snugly onto the wrist.
2. Snap the wrist cord to the wristband.
3. Plug the wrist cord into the dual-wire jack on
the operator remote. The green operator LED
will illuminate. This indicates that the operator is
properly grounded.
4. If this does not happen, examine the wrist cord for
continuity or damage and the wristband to ensure
that it fits securely. If you have dry skin, apply an
approved dissipative hand lotion such as
Menda
Reztore® ESD Hand Lotion
.
5. The AUX MAT jack located on the operator remote
is a grounded and unmonitored connection for
guests or supervisors. It is intended to be used with
a single-wire wrist strap.
Maintenance
JUMPER CONFIGURATIONS
Jumper Jumper
Position
Setting
JP5
Off
Audible alarm enabled
JP5
On
Audible alarm disabled
JP6
Off
Charge detection enabled
JP6
On
Charge detection disabled
Figure 4. Connecting single-wire and dual-wire wrist
straps to the operator remote
JP5 JP7
JP6
JP2
JP1
Figure 5. Jumper locations
WORKSURFACE MAT TEST LIMIT THRESHOLDS
MAT 2 MAT 1