background image

DESCO WEST 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178

DESCO EAST 

- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

TB-3069

 Page 1 of 7

© 2016 DESCO INDUSTRIES, INC.

Employee Owned

Combo Tester

Installation, Operation and Maintenance

Description

The Desco Combo Tester verifies the functionality of 

an operator’s wrist strap and footwear (footwear test 

requires foot plate).  It determines if an operator’s wrist 

strap and footwear will function correctly.  A rocker 

switch allows the operator to select a wrist strap or 

footwear test.  A green light indicates that the wrist strap 

or footwear is passing.  Red and yellow lights plus an 

audible alarm indicate when the wrist strap or footwear is 

failing.  If failure occurs, the tester will also display if the 

grounding device’s resistance is too low or too high.
The Combo Tester may also be used to test smocks 

or garments that feature a grounding mechanism for 

operators using a coiled cord connection.
The factory test limits are set to:
Wrist Straps:  750 kilohms and 10 megohms

Footwear: 

750 kilohms and 100 megohms

Limits meet the required limits for Compliance 

Verification of ANSI/ESD S20.20 (Wrist Strap System 

< 3.5 x 10

7

 ohms and Footwear < 1 x 10

9

 ohms tested 

per ESD TR53).
Contact 

Desco Customer Service

 if custom test limits 

are required.
The Combo Tester can be powered by a 9 volt battery or 

the Desco 

98256

 (120VAC) and 

98257

 (220VAC) power 

adapters (sold separately).  A warning light on the tester 

indicates when the battery power is too low and affecting 

the test results.  
Each Combo Tester is calibrated with accepted 

procedures and standards traceable to the National 

Institute of Standards and Technology (NIST) and 

includes a NIST certificate.

September 2016

Per ANSI/ESD S20.20 section 7.4 “A Compliance 

Verification Plan shall be established to ensure the 

Organization’s fulfillment of the technical requirements 

of the ESD Control Program Plan. Process monitoring 

(measurements) shall be conducted in accordance 

with a Compliance Verification Plan that identifies the 

technical requirements to be verified, the measurement 

limits and the frequency at which those verifications shall 

occur. The Compliance Verification Plan shall document 

the test methods and equipment used for process 

monitoring and measurements. … The test equipment 

selected shall be capable of making the measurements 

defined in the Compliance Verification Plan.” 
Per ANSI/ESD S1.1 Annex A.3 Frequency of System 

Testing “The wrist strap system should be tested daily to 

ensure proper electrical resistance.”
Per ESD Handbook ESD TR20.20 section 5.3.2.4.2 

Additional User Wrist Strap Testing “Proper testing of 

the wrist strap includes the resistance of the groundable 

point on the end of the cord, the cord itself, the resistor, 

the cord-to-cuff snap connector, the resistance of the 

interface of the cuff, the cuff/wrist interface, and the 

resistance of the person between the wrist and the hand 

that contacts the test electrode.”
Per ESD Handbook ESD TR20.20 section 5.3.2.2.2 

Wrist Strap Ground Cord “At first glance, the ground cord 

appears to be a relatively simple assembly. However, 

the design requirements are considerable, given the 

wide range of user applications and the durability 

requirements of constant tugging, flexing, and dragging 

over the edge of workstation tops and equipment 

chassis.”

Item

Description

19280

Combo Tester

19282

Combo Tester with Stand and Foot Plate

19283

Combo Tester with Stainless Steel Foot Plate

19261

Combo Tester Mounting Plate

98254

Stand and Foot Plate

98273

Stainless Steel Foot Plate

98256

* Power Adapter, 120VAC Input, 6VDC Output

98257

* Power Adapter, 220VAC Input, 9VDC Output

*Use only the Desco 

98256

 and 

98257

 power adapters 

with the Combo Tester.  Using any other power adapter 

may damage the unit and void the warranty.

  TECHNICAL BULLETIN TB-3069 

Made in the

United States of America

Figure 1.  Desco 

19280

 Combo Tester

Summary of Contents for 19280

Page 1: ...fillment of the technical requirements of the ESD Control Program Plan Process monitoring measurements shall be conducted in accordance with a Compliance Verification Plan that identifies the technical requirements to be verified the measurement limits and the frequency at which those verifications shall occur The Compliance Verification Plan shall document the test methods and equipment used for ...

Page 2: ...ton Head Screws 1 4 20 x 3 4 1 Allen Wrench 5 32 1 Flat Head Screw 8 32 x 5 8 1 Knurled Nut 8 32 1 Black Cap 1 Poster 1 Certificate of Calibration 19283 COMBO TESTER WITH STAINLESS STEEL FOOT PLATE 1 Combo Tester 1 Foot Plate Cord 5 inches 1 9V Battery 1 Stainless Steel Foot Plate 1 Foot Plate Cord 6 feet 1 Certificate of Calibration Figure 2 Desco 19282 Combo Tester with Stand and Foot Plate Figu...

Page 3: ...l foot plate 19283 98273 D Rocker Switch Toggle to the left when performing a footwear test Toggle to the right when performing a wrist strap test E Single Wire Wrist Strap Jack Insert your single wire wrist cord here to test your wrist strap F Test Switch Push down and hold your finger here to perform a test G Low Battery LED Illuminates when the battery power is low and needs to be replaced 9825...

Page 4: ... plate using the 3 included button head screws and allen wrench Figure 8 Combo Tester keyhole slots 4 Mount the Combo Tester onto the screws and pull it down to secure it into place 5 Set the Stainless Steel Foot Plate below the tester if applicable 6 Insert the 6 long foot plate cord s banana plug into the Combo Tester s foot plate jack Figure 9 Inserting the foot plate cord s banana jack into th...

Page 5: ... and or needs to be replaced NOTE 1 The Combo Tester may briefly display FAIL HIGH once the test button is released at the conclusion of a test Residual voltage in the circuit s capacitors causes the test to continue for a split second after the button is released NOTE 2 Failures may be caused by dry skin or minimal sweat layer For wrist straps try using an approved dissipative hand lotion such as...

Page 6: ... There are no user serviceable parts If your meter requires service beyond cleaning the test switch or foot plate please contact the factory Use a minimum of 80 isopropyl alcohol to clean the test switch Other cleaners are susceptible to leaving residue BATTERY REPLACMENT The low battery indicator flashes briefly every time the unit is used Replace the battery once the indicator becomes constant d...

Page 7: ...Desco Terms and Conditions Specifications COMBO TESTER Power Supply 9V Alkaline Battery or optional AC power adapter Operating Temperature 32 F to 104 F 0 to 40 C Wrist Strap Test Limit 750 kilohms to 10 megohms Footwear Test Limit 750 kilohms to 100 megohms Test Accuracy 20 Test Voltage 4 VDC Dimensions 3 3 x 5 6 x 1 5 Weight 0 5 lbs STAND AND FOOT PLATE Stand Height 36 Foot Plate Dimensions 18 x...