background image

TB-3072

 Page 1 of 6

© 2018 DESCO INDUSTRIES INC

Employee Owned

DESCO WEST 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178

DESCO EAST 

- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

Mini Monitor

Installation, Operation and Maintenance

Description

The Desco Mini Monitor is a single workstation 

continuous monitor. It continuously monitors the 

path-to-ground integrity of one operator and one ESD 

worksurface. The Mini Monitor eliminates the need for 

periodic testing and record keeping of wrist straps.
The Mini Monitor is designed with Wave Distortion 

Technology which provides stable continuous monitoring 

of the path-to-ground and presence of 1 megohm 

resistance of an operator’s wrist strap. Audio and visual 

alarms activate (in less than 50 milliseconds) when the 

operator unintentionally disconnects from the monitor or 

the wrist strap connection points are intermittent.  The 

Mini Monitor also serves as a ground point for an ESD 

worksurface and monitors for a path-to-ground of less 

than 500 megohms. All Mini Monitors are calibrated to 

NIST standards and include a certificate. 

July 2018

Wave Distortion Technology is the Most Reliable 

Technology for the Continuous Monitoring of 

Single-Wire (Conductor) Wrist Straps

“Wave Distortion” or vector impedance works by 

applying a continuous test voltage of 1.2 volts 

peak-to-peak at 1 to 2 microamperes (0.000002 

amperes) to the wrist strap that is connected to the 

continuous or constant monitor. The test voltage 

creates a sine wave that the monitor circuit compares 

to established patterns. By monitoring the “distortions”, 

or shape of the sine wave, Wave Distortion Technology 

determines if the monitored circuit is complete - the 

operator is in the circuit and the total equivalent DC 

resistance is within specifications. Wave Distortion 

Technology produces a very fast alarm time (<50 

milliseconds) and minimal false alarms.
ANSI/ESD S20.20 section 7.3 states “Compliance 

verification records shall be established and maintained 

to provide evidence of conformity to the technical 

requirements.” Per ANSI/ESD S1.1 Annex A.3 Daily 

(wrist strap system) testing may be omitted if constant 

monitoring used.”  Per ESD Handbook ESD TR 20.20 

section 5.3.2.4.4 “Typical Test programs recommend 

that wrist straps that are used daily should be tested 

daily. However, if the products that are being produced 

are of such value that knowledge of a continuous, 

reliable ground is needed, and then continuous 

monitoring should be considered or even required.”
The Mini Monitor and its accessories are available as 

the following item numbers:

Item

Description

19239

Mini Monitor, Black, North American Power 

Adapter

19242

Mini Monitor, Blue, with Jewel® Wrist Strap, 

North American Power Adapter

19243

Mini Monitor, Black, Universal Power Adapter

19258

Power Adapter, 100-240VAC Input, 24VDC 

150mA Output, IEC Inlet

19260

Power Adapter, 100-240VAC Input, 24VDC 

150mA Output, North America Plug

98221

Wave Distortion Monitor Verification Tester

Made in the

United States of America

  TECHNICAL BULLETIN TB-3072

Figure 1. Desco Mini Monitor

Summary of Contents for 19258

Page 1: ...he continuous or constant monitor The test voltage creates a sine wave that the monitor circuit compares to established patterns By monitoring the distortions or shape of the sine wave Wave Distortion Technology determines if the monitored circuit is complete the operator is in the circuit and the total equivalent DC resistance is within specifications Wave Distortion Technology produces a very fa...

Page 2: ...ashers 2 Flat Head Screw 6 32 x 1 4 1 Power Adapter 24VDC North America Plug 1 Certificate of Calibration 19243 Mini Monitor Universal Power Adapter 1 Mini Monitor 2 Countersunk Washers 2 Flat Head Screw 6 32 x 1 4 1 10mm Interchangeable Park Snap 1 10mm Operator Jack Adapter 1 Power Adapter 24VDC IEC Inlet 1 Certificate of Calibration Figure 2 North American power adapter included with the 19239 ...

Page 3: ...park a wrist strap when leaving the workstation without creating a false alarm Touch the park snap and the monitor s audible alarm will disable for approximately 10 seconds Use this time to disconnect the wrist cord from the wristband and attach it to the park snap or remove the banana plug from the jack Upon returning to the workstation and disconnecting the wrist cord from the park snap the oper...

Page 4: ...ark snap and 10mm banana jack adapter for operators who use wrist cords with 10mm terminations Use the park snaps knurled rims to unscrew the 4mm park snap from the monitor and install the 10mm park snap to the monitor Plug the 10mm operator jack adapter into the monitor s operator jack Installation 1 Remove the Mini Monitor from the carton and inspect for damage 2 Locate an appropriate AC outlet ...

Page 5: ... 2 Snap the wrist cord to the wristband 3 Plug the wrist cord into the operator jack The green operator LED will illuminate This indicates that the operator is properly grounded 4 If this does not happen examine the wrist cord for continuity or damage and the wristband to ensure that it fits securely If you have dry skin apply an approved dissipative hand lotion such as Menda Reztore ESD Hand Loti...

Page 6: ... megohms 20 Operator Test Voltage 1 2V peak to peak 1 2µA open circuit Worksurface Test Voltage 5 to 7 5V open circuit Alarm Response Time 50 ms Country of Origin United States of America This cannot be verified with standard DC test equipment The continuous monitor is an impedance sensing device and the limits are determined by the magnitude and angle of the impedance The worksurface mat must hav...

Reviews: