background image

11

104353

OWNER’S MANUAL

Figure 19 - Removing Log Base Assembly
From Fireplace

 CAUTION: Do not pick up log

base assembly by burners. This
could damage burners. Only
handle base by grates.

Installation Items Needed

• 5/16" hex socket wrench or nut-driver

• Phillips screwdriver

• sealant (resistant to propane/LP gas, not

provided)

1.

Remove fireplace screen. Remove two
screws that hold fireplace screen in
place for shipping. These screws are
located near top of screen. Discard
screws. Lift fireplace screen up and pull
out to remove.

2.

Remove screws that attach log base
assembly to fireplace (see Figure 19).
Carefully lift up log base assembly and
remove from fireplace (see Figure 19).

Note:

 If adding the G8000 series brick liner

accessory, install it now. Follow instruc-
tions in G8000 accessory kit.

CONNECTING FIREPLACE
TO GAS SUPPLY

INSTALLATION

Continued

Figure 20 - Attaching Flexible Gas Lines Together

 NOTICE: Most building codes do
not permit concealed gas con-
nections. A flexible gas line is
provided to allow accessibility
from the fireplace (see Figure 20).
The flexible gas supply line con-
nection to the manual shutoff
valve should be accessible.

Flexible Gas Line from
Fireplace Gas Regulator
Provided with Fireplace

To Fireplace
Gas Regulator

Flare Union

Flexible Gas Line from
Manual Shutoff Valve
Provided by Installer

Manual Shutoff Valve

To Gas Supply

3.

Route flexible gas line (provided by
installer) from manual shutoff valve to
fireplace. Route flexible gas supply line
through one of the access holes.

Figure 18 - Gas Connection

* Purchase the optional A.G.A. design-cer-
tified manual shutoff valve from your dealer.
See  Accessories, pages 22 and 23.

Installation must include a manual shutoff
valve, union, and plugged 1/8" NPT tap.
Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from
fireplace (see Figure 17, page 10).

Check your building codes for any special
requirements for locating manual shutoff
valve to fireplaces.

Apply pipe joint sealant lightly to male
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.

Continued

 CAUTION: Use pipe joint seal-

ant that is resistant to liquid pe-
troleum (LP) gas.

Install sediment trap in supply line as shown
in Figure 18. Locate sediment trap where it
is within reach for cleaning. Locate sedi-
ment trap where trapped matter is not likely
to freeze. A sediment trap traps moisture
and contaminants. This keeps them from
going into fireplace gas controls. If sedi-
ment trap is not installed or is installed
wrong, fireplace may not run properly.

4.

Attach a 45

°

 flare union gas connector

to flexible gas line from gas supply (see
Figure 20). Connect flare union to flex-
ible gas line attached to gas regulator
of fireplace (see Figure 20).

5.

Check all gas connections for leaks. See
Checking Gas Connections, page 12.

6.

Replace log base assembly back into
fireplace. Feed flexible gas line into fire-
place base area while replacing log base
assembly. Make sure the entire flexible
gas line is in fireplace base area. Reat-
tach log base assembly to fireplace with
screws removed in step 2.

A.G.A. Design-
Certified Manual
Shutoff Valve With
1/8" NPT Tap*

3" Minimum

From Gas
Meter (11"
W.C. to
14" W.C.
Pressure)

Approved Flexible
Gas Line

Cap     Pipe    Tee

 Nipple  Joint

Sediment Trap

Summary of Contents for VYGF33PR

Page 1: ...n and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice ormaintenancecancause injury or property damag...

Page 2: ...ebris could fall into the control area of fireplace 8 You must operate this fireplace with the fireplace screen and hood in place Make sure fireplace screen and hood are in place before running firepl...

Page 3: ...UNPACKING 1 With utility knife cut the carton all the way around above the staples on the bottom tray Lift the carton off the heater Remove packing Note The hood is located in the packing on the righ...

Page 4: ...ou classify your space and provide adequate ventilation Unusually Tight Construction The air that leaks around doors and win dowsmayprovideenoughfreshairforcom bustion and ventilation However in build...

Page 5: ...______ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual...

Page 6: ...ilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors orspacesopentotheoutdoors Thes...

Page 7: ...ssem bling and attaching brass trim to fireplace 1 Remove packaging from three pieces of brass trim 2 Locate four brass screws two adjust ing plates with set screws and two shims in the hardware packe...

Page 8: ...net mantel hearth base and trim accessories Assembly instruc tions are included with each accessory 2 When installing blower install a prop erly grounded 120 volt three prong electrical outlet at fire...

Page 9: ...e 16 page 10 Follow the instructions below to install the fireplace in this manner Figure 15 Attaching Fireplace to Wall Studs Nailing Flanges Nails or Wood Screws 39 3 8 27 7 8 55 5 8 35 1 2 Figure 1...

Page 10: ...urface above the Firebox Hood Mantel Shelf 13 16 19 21 2 1 2 6 8 10 Note All vertical measurements are from top of fireplace hood opening to bottom of mantel shelf These minimum clearances replace any...

Page 11: ...optional A G A design cer tifiedmanualshutoffvalvefromyourdealer See Accessories pages 22 and 23 Installation must include a manual shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within re...

Page 12: ...fireplace and its individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage fireplace gas regulator 2 Cap off open end of gas pipe where manual shutoff...

Page 13: ...only parts specifically approved with this heater may result in property damage or personal injury INSTALLING LOGS Itisveryimportanttoinstallthelogsexactly as instucted Do not modify logs Only use log...

Page 14: ...loss of life FOR YOUR SAFETY READ BEFORE LIGHTING OPERATING FIREPLACE WARNING Burnerswillcome on automatically within one minute when the remote selector switch is in the ON position after the pilot...

Page 15: ...to pilot GHRCT Operation 2 Select the MANUAL or AUTO but ton on the hand held remote control unit GHRCT only see Figure 28 In MANUAL mode turn burners on or off by pressing the ON or OFF buttons on t...

Page 16: ...e blower will start when the thermostat sensesasufficientincreaseinfireboxtem perature Note Your gas logs and thermostat blower will not turn on and off at the same time The fireplace may run for seve...

Page 17: ...5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor c...

Page 18: ...ion 1 Refer to Air for Combustion and Venti lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line che...

Page 19: ...Warning statement above 1 Improper log placement 2 Drafts or other air currents affecting flame pattern 3 Air holes at burner inlet blocked 4 Burner flame holes blocked OBSERVED PROBLEM Fireplace prod...

Page 20: ...ified heat propane LP gas supply may be low When gas quality is bad pilot will not stay lit burners will produce flames and soot heater will backfire when lit Youmayfeelyourgaspressureistoolowor gas q...

Page 21: ...areas burner and circu lating air passageways of heater clean Inspect these areas of heater before each use Have heaterinspectedyearlybyaquali fied service person Heater may need more frequent cleanin...

Page 22: ...ted on the back page of this manual QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQQQQ QQQ QQQ QQQ QQQQQQQQQQ QQQQQQQQQQ QQQQQQQQQQ CABINET MANTEL GM100F Series Walnut Finished GM101U Seri...

Page 23: ...selected on the wall thermostat and the log heater will automatically cycle from pilot to the heat setting selected WALL MOUNT ON OFF SWITCH GWMS2 Not Shown For all models Allows the gas log heater t...

Page 24: ...UNVENTED PROPANE LP GAS FIREPLACE DESA INTERNATIONAL ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL VYGF33PR 17 O F F P I L O T O N H I L O 8 12 26 7 6 4 3 2 1 5 9 4 14 13 25 15 16 21 11 10 19 20 19 2...

Page 25: ...ce Injector 1 8 102772 01 Burner 2 9 M11084 38 Screw 8 x 38 2 10 104236 01CK Painted Base Assy 1 11 M12461 26 Screw 10 x 32 4 12 104238 01CK Firebox Bottom 1 13 103284 03 Wiring Harness 1 14 098265 02...

Page 26: ...26 104353 UNVENTED PROPANE LP GAS FIREPLACE DESA INTERNATIONAL ILLUSTRATED PARTS BREAKDOWN FIREPLACE VYGF33PR 4 11 14 8 14 9 3 14 9 9 2 1 6 7 10 14 12 5 14 13 16 15...

Page 27: ...ght Front Side 1 4 102759 02CK Left Front Side 1 5 098304 01 Phillips Pan Head Screw 10 9 6 104239 01CK Top Front Louver 1 7 101712 02 Firebox Hood 1 8 101348 01 Firebox Support 2 9 099230 02 Shoulder...

Page 28: ...uch other costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCL...