www.desatech.com
901273-01H
17
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor’s phone. Fol
-
low the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT:
Operating log set where impurities in air exist may create odors. Cleaning sup
-
plies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc.,
create fumes. These fumes may mix with combustion air and create odors. These odors will
disappear over time.
TroublesHooTIng
Continued
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
Log set produces a clicking/
ticking noise just after burner
is lit or shut off.
1. Metal expanding while
heating or contracting while
cooling.
1. This is normal with most log
sets. If noise is excessive,
contact qualified service
person.
Log set produces unwanted
odors.
1. Log Set burning vapors
from paint, hair spray, glues,
cleaners, chemicals, new
carpet, etc. (See
IMPOR-
TANT
statement above.)
2. Gas leak.
See Warning
statement at top of page.
1. Open flue to maximum. Stop
using odor causing products
while log set is running.
2. Locate and correct all leaks
(see
Checking Gas Connec-
tions
, page 7).
Gas odor even when control
knob is in OFF position.
1. Gas leak.
See Warning
statement at top of page.
2. Control valve defective.
1. Locate and correct all leaks
(see
Checking Gas Connec-
tions
, page 7).
2. Replace control valve.
Gas odor during combustion. 1. Gas leak.
See Warning
statement at top of page.
1. Locate and correct all leaks
(see
Checking Gas Connec-
tions
, page 7).