background image

www.desatech.com

119426-01A

4

SAFETy INFORMATION

Continued

1.  This appliance is only for use with the type of 

gas indicated on the rating plate. This appliance 

is not convertible for use with other gases. 

2.  Do not place propane/LP supply tank(s) in

-

side any structure. Locate propane/LP supply 

tank(s) outdoors (propane/LP units only).

3.  If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not use 

any phone in your building

• immediately call your gas supplier from a 

neighbor’s phone. Follow the gas supplier’s 

instructions

• if you cannot reach your gas supplier, call 

the fire department

4.  This heater shall not be installed in a bedroom 

or bathroom, unless installed as a vented appli

-

ance. See 

Installing Damper Clamp Accessory 

for Vented Operation

, page 12 (Remote-Ready 

Models Only).

5.  Before  installing  in  a  solid  fuel  burning 

fireplace, the chimney flue and firebox must 

be cleaned of soot, creosote, ashes and loose 

paint by a qualified chimney cleaner. Creosote 

will ignite if highly heated. A dirty chimney 

flue may create and distribute soot within 

the house. Inspect chimney flue for damage. 

If damaged, repair flue and firebox before 

operating heater.

6.  Do not burn solid-fuel in a masonry or UL127 

factory-built fireplace in which a vent-free 

room heater is installed.

7.  If fireplace has glass doors, never operate this 

heater with glass doors closed. If you operate 

heater with doors closed, heat buildup inside 

fireplace will cause glass to burst. Make sure 

there are no obstructions across openings of 

fireplace.

8.  To prevent the creation of soot, follow the 

instructions in 

Cleaning and Maintenance

page 26.

9.  Before using furniture polish, wax, carpet 

cleaner or similar products, turn heater off. If 

heated, the vapors from these products may 

create a white powder residue within burner 

box or on adjacent walls and furniture.

10.  This heater needs fresh, outside air ventilation 

to run properly. This heater has an Oxygen 

Depletion Sensing (ODS) safety shutoff system. 

The ODS shuts down the heater if enough fresh 

air is not available. See 

Air for Combustion and 

Ventilation

, page 6. If heater keeps shutting off, 

see 

Troubleshooting

, page 28.

11.  Do not run heater

• where flammable liquids or vapors are used 

or stored

• under dusty conditions

12.  Do not use this heater to cook food or burn 

paper or other objects.

13.  Do not use heater if any part has been exposed 

to or under water. Immediately call a qualified 

service technician to inspect the room heater 

and to replace any part of the control system 

and any gas control which has been under 

water. 

14.  Do not operate heater if any log is broken. Do 

not operate heater if a log is chipped (dime-

sized or larger). 

15.  Turn heater off and let cool before servicing, 

installing or repairing. Make sure the selector 

switch is in the OFF position (Remote-Ready 

Models Only). Only a qualified service person 

should install, service or repair heater.

16.  Make sure the selector switch is in the OFF 

position when you are away from home for 

long periods of time (Remote-Ready Models 

Only). 

17.  Remote-ready heaters must not be connected 

to any external electrical source.

18.  Operating heater above elevations of 4,500 

feet may cause pilot outage.

19.  To prevent performance problems, do not 

use propane/LP fuel tank of less than 100 lb. 

capacity (propane/LP units only).

20.  Provide  adequate  clearances  around  air 

openings.

UNPACkING

 CAUTION: Do not remove the 

data plates from the grate assembly. 

The data plates contain important 

warranty and safety information.

1.  Remove logs and heater base assembly from 

carton. 

Note:

 Do not pick up heater base as

-

sembly by burners. This could damage heater. 

Always handle base assembly by grate. 

2.  Remove all protective packaging applied to 

logs and heater for shipment.

3.  Check all items for any shipping damage. If 

damaged, promptly inform dealer where you 

bought heater.

Summary of Contents for VUL 18R, VUL24R, VUL30R, HR B3930, HR 3924R, CRB3624T, VUL 18T, VUL24T, VUL30T, HR B3624T

Page 1: ...atelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qual...

Page 2: ...e agency or the gas supplier WARNING This appliance is for installation only in a solid fuel burning mason ry or UL127 factory built fireplace or in alistedvent less firebox enclosure It is design cer...

Page 3: ...your guide to safe and proper operation of this fireplace WARNING Any change to this heater or its controls can be dangerous WARNING Do not use a blower insert heat exchanger insertorotheraccessoryno...

Page 4: ...burner box or on adjacent walls and furniture 10 This heater needs fresh outside air ventilation to run properly This heater has an Oxygen DepletionSensing ODS safetyshutoffsystem The ODS shuts down t...

Page 5: ...ater may also be operated as a vented decorative ANSI Z21 60 product by opening the flue damper Non Thermostat Models Only Safety Device This heater has a pilot with an Oxygen Deple tion Sensing ODS s...

Page 6: ...tion However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is defined as construction where a walls and ceilings exposed to the out si...

Page 7: ...of Btu Hr used The space in the above example is a confined space because the actual Btu Hr used is more than the maxi mum Btu Hr the space can support You must provide additional fresh air Your optio...

Page 8: ...culatetheheatthroughoutthe house In the event of a power outage you can use this heater as your primary heat source WARNING A qualified ser vice person must install heater Follow all local codes NOTIC...

Page 9: ...ere you bought heater for proper type heater WARNING This appliance is equipped for natural or pro pane LP gas Field conversion is not permitted INSTALLATION AND CLEARANCES For Vent Free Operation WAR...

Page 10: ...f noncombustible material is more than 12 you may need the hood accessory to deflect heat away from your mantel shelf See Figure 5 and Figures 6 and 7 page 9 for minimum clearances IMPORTANT If you ca...

Page 11: ...el Clearances When Using Hood Minimum Non Combustible Material Minimum Non Combustible Material Height Distances to Underside of Mantel Top of Fireplace Opening Underside of Mantel Shelf 12 8 A 18 14...

Page 12: ...cluded with clamp accessory See chart below for minimum permanent flue opening you must provide Attach damper clamp so the minimum permanent flue opening will be maintained at all times Area of Variou...

Page 13: ...oved flexible gas hose to gas regulator of heater see Figure 11 For Remote Ready models connect approved flexible gas hose to inlet side of gas control see Figure 12 IMPOR TANT Hold gas regulator with...

Page 14: ...gas connector if allowed by local codes not provided ACSAdesign certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA desi...

Page 15: ...sediment trap traps moisture and contaminants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong heater may not run properly CAUTION Avoid damage t...

Page 16: ...k reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 17 2 Pressurize supply piping system by either opening propane LP supp...

Page 17: ...o unit 2 Carefully remove logs and set aside 3 Locate mounting screws on sides of heater base assembly and remove screws Set screws aside for reinstallation 4 Disconnect gas line from heater base as s...

Page 18: ...ote Make sure excess wire does not inter fere with burner or pilot 10 If heater was removed from fireplace before installation of remote accessory see Install ing Heater Base Assembly on page 12 to re...

Page 19: ...ottom log in center of the base assem bly as shown in Figure 27 2 Rest rear log in back corner sections of base as semblyasshowninFigure27 Make sure log is completely vertical and not leaning in towar...

Page 20: ...iance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING If fireplace has glass doors never operate this heater with glass doors...

Page 21: ...level The burners should light Set control knob to any heat level between HI and LO CAUTION Do not try to ad just heating levels by using the equipment shutoff valve Operating Heater Continued Figure...

Page 22: ...page 23 WARNING Burners will come onautomaticallywithinoneminute when the selector switch is in the ON position after the pilot is lit Remote Ready Models FOR YOUR SAFETY READ BEFORE LIGHTING WARNING...

Page 23: ...t steps 4 through 8 page 22 and above 9 Slightly push in and turn control knob coun terclockwise to the ON position 10 Wait one minute and switch selector switch to theONpositiontolightburners Note AU...

Page 24: ...burner turns on Hold the control button again until burner turns off see Figure 34 To Lock press both buttons on hand held remote control until light stops flashing Hand held remote control is now loc...

Page 25: ...e receiver continuously receives signals from the hand held remote to control the room temperature If the hand held remote is misplaced obstructed or for any reason cannot transmit to the receiver the...

Page 26: ...by a qualified service person Heater may need more frequent cleaning due to excessive lint fromcarpeting pethair bedding material etc WARNING Failure to keep the primary air opening s of theburner s...

Page 27: ...mpressed air is not available Cleaning and Maintenance Continued LOGS If you remove logs for cleaning refer to Install ing Logs page 18 to properly replace logs Replace log s if broken or chipped dime...

Page 28: ...n PILOT position 4 Air in gas lines when installed 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor...

Page 29: ...terlock system to reset Repeat ignition operation 4 Fully open equipment shutoff valve 5 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 26 or re...

Page 30: ...line checked by local natural or propane LP gas company 3 Observe minimum installa tion clearances see pages 9 through 11 4 Clean burners see Cleaning and Maintenance page 26 or replace burner orific...

Page 31: ...r between con trol valve and burner 2 Gas leak See Warning statement at top of page 1 Thermostat sensing bulb needs to be repositioned Thermo stat Controlled Models Only 2 Hand held remote control is...

Page 32: ...t sensing bulb IMPORTANT Do not force or bend the thermostat sensing bulb or capillary Capillary Screw Retaining Clamp Thermostat Sensing Bulb Figure 43 Location of Gas Valve Assembly and Thermostat S...

Page 33: ...s Pressure in of water Max 10 5 W C Min 5 W C VUL24PT VUL30Pt HRB3624PT Rating Variable 25 000 36 000 Btu Hr Type Gas Propane LP Ignition Electronic Manifold Pressure 7 9 W C Inlet Gas Pressure in of...

Page 34: ...Log 2 1 4 113621 04 113621 10 113621 16 Middle Left Log 2 1 5 113621 05 113621 11 113621 11 Bottom Log 3 Remote 1 113621 05 113621 19 113621 19 Bottom Log 3 T stat 6 113621 06 113621 12 113621 18 Rea...

Page 35: ...aceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 42 of this manual 1 3 2 KEY NO PART NUMBER DESCRIPTION QTY CRB2618NR CRB2618PR HRB3...

Page 36: ...9426 01A 36 Illustrated Parts Breakdown Thermostat controlled Models VUL18NT VUL18PT VUL24NT VUL24PT VUL30NT VUL30PT HRB3624NT AND HRB3624PT LPG 11 10 4 1 8 3 12 8 2 5 6 7 24 25 21 2 23 22 15 13 16 9...

Page 37: ...rner Injector Propane LP 1 101004 15 1 12 101004 11 Front Burner Injector Natural 1 101004 10 Front Burner Injector Propane LP 1 101004 22 Front Burner Injector Natural 1 101004 06 Front Burner Inject...

Page 38: ...ch com 119426 01A 38 ILLUSTRATED PARTS BREAKDOWN Remote Ready Variable Control Models VUL18NR VUL18PR VUL24NR VUL24PR VUL30NR VUL30PR LPG 5 6 21 14 22 14 23 24 2 19 20 16 1 18 17 10 11 4 3 8 8 12 14 1...

Page 39: ...Injector Natural 1 101004 02 Rear Burner Injector Propane LP 1 12 101004 11 Front Burner Injector Natural 1 101004 10 Front Burner Injector Propane LP 1 101004 08 Front Burner Injector Natural 1 10100...

Page 40: ...40 ILLUSTRATED PARTS BREAKDOWN Remote Ready Variable Control Models CRB2618NR CRB2618PR CRB3624NR CRB3624PR CRB3630NR CRB3630PR HRB3624NR AND HRB3624PR LPG 5 6 21 14 22 14 23 24 2 19 20 16 1 18 17 10...

Page 41: ...Injector Propane LP 1 12 101004 11 Front Burner Injector Natural 1 101004 10 Front Burner Injector Propane LP 1 101004 08 Front Burner Injector Natural 1 101004 06 Front Burner Injector Propane LP 1...

Page 42: ...ts Technical Service Department at 1 866 672 6040 When calling DESA Heating Products have ready your name your address model and serial numbers of your heater how heater was malfunctioning type of gas...

Page 43: ...MATE FIREBOXES Not Shown Available in 32 36 and 42 models Circu lating fireboxes feature louvers and an optional blower Non circulating smooth face models are ideal for custom trim applications such a...

Page 44: ...talled by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal w...