5. This heater needs fresh, outside air ventilation
to run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater if
not enough fresh air is available. See
Air for
Combustion and Ventilation,
page 5.
6. Keep all air openings in front and bottom of
heater clear and free of debris. This will insure
enough air for proper combustion.
7. If heater shuts off, do not relight until you
provide fresh, outside air. If heater keeps
shutting off, have it serviced.
8. Do not run heater
• where flammable liquids or vapors are used
or stored
• under dusty conditions
9. Do not use heater if any part has been under
water. Immediately call a qualified service
technician to inspect the room heater and to
replace any part of the control system and any
gas control which has been under water.
10. Turn off heater and let cool before servicing.
Only a qualified service person should service
and repair heater.
11. Operating heater above elevations of 4,500
feet (1372 m) could cause pilot outage.
12. To prevent performance problems, do not
use propane/LP fuel tank of less than 100
psi (690 kPa) capacity.
13. Before using furniture polish, wax, carpet
cleaner or similar products, turn heater off. If
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
14. Provide adequate clearances around air
openings.
LOCAL CODES
Install and use heater with care. Follow all local
codes. In the absence of local codes, use the latest
edition of
The National Fuel Gas Code, ANSI
Z223.1/NFPA 54
*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
SAFETY INFORMATION
Continued
Figure 1 - Infrared Tower Heater
UNPACKING
1. Remove heater from carton.
2. Remove all protective packaging applied to
heater for shipment.
3. Check heater for any shipping damage. If
heater is damaged, promptly contact the dealer
to where you bought heater.
PRODUCT FEATURES
SAFETY DEVICE
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot is a required feature for vent-free room
heaters. The ODS/pilot shuts off the heater if there
is not enough fresh air.
IGNITION SYSTEM
This heater has an electronic ignitor to light heater
fuel supply, which requires a AAA battery.
THERMOSTATIC HEAT CONTROL
Your unit is thermostatically controlled when heat-
er and remote control are set to the proper modes.
This results in the greatest heater comfort.
PRODUCT
IDENTIFICATION
Electronic
Ignitor
Grill
Plaque
(behind
Grill)
On/Pilot/Off Knob
Manual/Auxiliary
Knob