6.  Repeat  process  for  opposite  door  as

-

sembly.

7.  To adjust doors, slide them partially open. 

Using  a  screwdriver,  loosen  hold-down 
screws in the spring clip (see Figure 34) 

and pivot plate.

8.  Close  both  doors  until  evenly  joined  at 

the middle and note gap at outer edges 

of face.

9.  Reopen one door at a time and retighten 

upper and lower hold-down screws.

10. Repeat process until both doors are even

-

ly joined, spaced and working freely.

  CAUTION:  The  glass  pan-

els  become  very  hot  while  the 

appliance  is  operating.  Do  not 

attempt  to  adjust  or  clean  the 

glass doors until the appliance 

has fully cooled. 

The doors may be removed for replacement 
or cleaning as follows:
1.  Partially open door and press up on upper 

spring clip with a screw driver until outer 
top pivot pin is free of clip.

2.  Fully fold frame assembly and slide upper 

edge  towards  center  of  firebox  opening 
until guide pins are free of frame rail (see 
Figure 35).

  CAUTION:  Always  operate 

the appliance with the doors ei

-

ther fully opened or fully closed. 

Operating  the  appliance  with 

the doors partially open can re-

sult in improper venting of flue 

products.

INstallatIoN

Continued

Figure 34 - Adjusting Glass Doors

Spring 
Clip

Hold-Down 
Screw

Side 
Front 
Face

Partially 
Opened 
Door

Figure 35 - Removing Glass Doors

Spring Clip

Press 

Spring Clip 

to Release 

Pivot Pin

Remove Bottom Pin 

From Pivot Plate While 
Sliding Door Out of the 
Upper Track

Pivot Plate

Fold Bi-Fold 

Door After 

Releasing 

Spring Clip 
and Slide 
Door Out of 
Upper Track

OPENING VENT DAMPER

Vent damper must be locked in the full open 
position  before  operating  fireplace.  If  vent 
damper is not open, fireplace will not light.

CLOSE

OPEN

VENT DAMPER MUST BE LOCKED

IN THE FULL OPEN POSITION

TO OPERATE THE APPLIANCE

Figure 36 - Opening Vent Damper

Summary of Contents for VM36E(B

Page 1: ...ot try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you...

Page 2: ...e may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by state or local codes This appliance is only for use with the type of gas indi cated on the ra...

Page 3: ...ating plate This appliance is not convertible for use with other gases unless a certified kit is used 2 For propane LP fireplace do not place propane LP supply tank s inside any structure Locate propa...

Page 4: ...ped on cardboard Three 3 plastic bags containing lava rock pan and ember materials Rear Log Remove two plastic quick ties from around burner and grate Grate Stand Lift off of burner pan Check all item...

Page 5: ...piping system at test pressures equal to or less than 1 2 psig 3 5 kPa For the purpose of input adjustment two pressure taps for IN and OUT pressures are provided on the gas control valve for test ga...

Page 6: ...66 kPa 10 5 WC 2 66 kPa Orifice Size 30 29 GAS RATING PROPANE LP M36P B H VM36P B H M42P B H VM42P B H Max Input Rating 40 000 Btu Hr 45 000 Btu Hr Manifold Pressure 10 WC 2 49 kPa 10 WC 2 49 kPa Min...

Page 7: ...ts in relation to fireplace opening Spacer 3 7 6 cm 1 1 2 3 8 cm Max B 6 15 2 cm A 12 22 9 cm Combustible Materials Header Figure 5 Mantel Clearances Side View Cross Section 1 1 2 3 8 cm Max 3 7 6 cm...

Page 8: ...k iron pipe does not mate with fitting at the end of flexible gas line remove fitting and replace with a 37 degree flare 3 4 12 1 2 NPT female fitting WARNING When finishing appliance do not overlap c...

Page 9: ...terminate vertically into a listed type vent cap and extend a sufficient height through an approved roof flashing roof jack or a roof thimble At all points the listed clearances must be maintained Ve...

Page 10: ...installation It is not recommended that this appliance be common vented with an existing gas burning appliance However if it becomes necessary to common vent this appliance the venting system must be...

Page 11: ...Control Receiver Extension Cord Ignition Module Plug NOTICE This appliance is equipped with a vent safety shutoff switch which will shut down the appliance in the case of aventingproblem Donotbypass...

Page 12: ...LLC recommends that a black iron gas line be routed from the gas source through a sediment trap shown in Figure 18 and into appliance Once connected through appliance a flexible gas line may be used...

Page 13: ...pear leaks can be detected and corrected Donotuseanopenflameforleak testing and do not operate any appliance if a leak is detected Installation Continued Complete your gas installation by connect ing...

Page 14: ...into notch on left of log 2 see Figure 25 Rest lower end of log 5 on grate as shown in Figure 26 6 Insert lower end of log 6 between first two grate fingers as shown in Figure 26 and position upper en...

Page 15: ...Place upper end of log 5 into notch on top inner right of log 1 see Figure 29 Rest lower end of log 5 on middle grate finger as shown in Figure 30 6 Place log 6 into notch on top right of log 1 see Fi...

Page 16: ...Sealing Between Appliance and Framing Installing optional GLASS DOOR Accessory CAUTION Use only glass doors certified for use with this appliance Note Glass door may be heavy for some individuals If t...

Page 17: ...s free of clip 2 Fully fold frame assembly and slide upper edge towards center of firebox opening until guide pins are free of frame rail see Figure 35 CAUTION Always operate the appliance with the do...

Page 18: ...off Valve Adjustment Screw FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss...

Page 19: ...ure to press ON OFF buttons on hand held remote control unit for up to 3 seconds to assure proper operation 2 Press the ON OFF button to turn burner on and off Check pilot flame pattern and burner fla...

Page 20: ...dust dirt or lint logs If you remove logs for cleaning refer to log placement information on page 12 to properly replace logs Use a vacuum cleaner to remove any carbon buildup on logs Replace log s i...

Page 21: ...e Wiring Diagram Service Hints When Gas Pressure Is Too Low pilot will not stay lit burner will have delayed ignition fireplace will not produce specified heat propane LP gas supply may be low if usin...

Page 22: ...tage REMEDY 1 Check to see if you have gas supply and that equipment shutoff valve is opened 2 Repeat lighting procedure several times to purge all air out of lines If after repeated attempts applianc...

Page 23: ...ne LP gas low fuel supply 3 Gas leak See Warning statement at top of page 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2...

Page 24: ...EP B H M42E B H M42EP B H VM36E B H VM36EP B H VM42E B H and VM42EP B H 51 21 1 10 11 6 50 50 22 3 8 20 9 52 13 43 14 45 48 62 44 40 23 4 39 17 2 42 41 9 55 7 46 19 47 7 47 18 5 16 12 15 52 33 31 28 3...

Page 25: ...flector 1 25 11165 11165 Screw 10 x 5 8 2 26 107796 01 107796 02 Grate Assy 1 27 107742 01 107742 02 Burner Pan 1 28 107795 01 107831 01 Burner Tube 1 29 107748 01 107748 01 Burner Brckt 1 30 107985 0...

Page 26: ...42EH 1 106660 01 107816 01 Rear Refractory Std Brick VM36EB VM42EB 1 108166 01 108171 01 Rear Refractory Herringbone VM36EH VM42EH 1 15 106661 02 107818 02 Bottom Rear Refractory Std Brick M36 ME42 M3...

Page 27: ...d VM36P B H KEY NO PART NO DESCRIPTION QTY 107999 01 Log Set 1 108724 01 Right Front 9 Split Log 1 2 901098 01 Rear Log 1 3 108720 01 Top Right Log 11 3 4 1 4 108721 01 Top Right Log 16 1 5 108722 01...

Page 28: ...1 Left Front Log 11 1 2B 108839 01 Right Front Log 15 3 4 Round 1 3 108722 01 Top Left Log 13 1 2 Y Log 1 4 108838 01 Inside Top Left Log 15 3 4 Split 1 5 108721 01 Inside Top Right Log 16 1 6 108720...

Page 29: ...and M42P B H BL36 36 Refractory Standard Brick BL42 42 Refractory Standard Brick BL36H 36 Refractory Herringbone Brick BL42H 42 Refractory Herringbone Brick For VM36 B H VM36P B H VM42 B H and VM42P...

Page 30: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 31: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 32: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Reviews: