background image

15

901847

OWNER’S MANUAL

TROUBLESHOOTING

Continued

www.desatech.com

Continued

OBSERVED PROBLEM

When ignitor button is pressed, there is no
spark at pilot (GA9003 Only)

When ignitor button is pressed, there is
spark at pilot but no ignition (GA9003 Only)

Pilot lights but flame goes out when control
knob is released (GA9003 Only)

Burner does not light after pilot is lit
(GA9003 Only)

Delayed ignition burner (GA9003 Only)

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched by any

metal or tubing. Keep ignitor cable dry

3. Scrape away paint on bracket for better

contact with ground on piezo ignitor

4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace electrode
7. Reposition electrode

1. Turn on gas supply or open equipment

shutoff valve

2. Turn control knob to PILOT position
3. Press in control knob while in PILOT

position

4. Continue holding down control knob. Re-

peat igniting operation until air is removed

5. Adjust pilot flame for approximately

2" blue flame

6. Clean pilot (see Cleaning and Mainte-

nance, page 17) or replace pilot assembly

7. Replace gas control

1. Press in control knob fully
2. After pilot lights, keep control knob

pressed in 30 seconds

3. Fully open equipment shutoff valve
4. A) Contact local natural or propane/LP

gas company

B) Clean pilot (see Cleaning and Mainte-
nance
, page 17) or replace pilot assembly

5. Hand tighten until snug, then tighten

1/4 turn more

6. Replace thermocouple
7. Replace control valve

1. Clean burner orifice
2. Contact local natural or propane/LP gas

company

3. Replace burner orifice
4. Reconnect leads

1. Adjust pilot flame for approximately

2" blue flame

2. Replace pilot orifice set

POSSIBLE CAUSE

1. Ignitor electrode not connected to igni-

tor cable

2. Ignitor cable pinched or wet

3. Bad ground on piezo ignitor

4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned wrong

1. Gas supply turned off or equipment

shutoff valve closed

2. Control knob not in PILOT position
3. Control knob not pressed in while in

PILOT position

4. Air in gas lines when installed

5. Pilot adjustment screw closed

6. Pilot is clogged

7. Low gas pressure

1. Control knob not fully pressed in
2. Control knob not pressed in long enough

3. Equipment shutoff valve not fully open
4. Pilot flame not touching thermocouple,

which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged pilot

5. Thermocouple connection loose at con-

trol valve

6. Thermocouple damaged
7. Control valve damaged

1. Burner orifice clogged
2. Inlet gas pressure is too low

3. Burner orifice diameter is too small
4. Thermocouple leads disconnected or im-

properly connected

1. Pilot flame needs adjusting

2. Wrong pilot orifice

Summary of Contents for Vanguard VVTR18

Page 1: ...ional procedures For assistance or additional information consult a qualified installer service agency or the gas supplier WARNING This appliance is for installation only in a solid fuelburningmasonryorUL127 factory built fireplace con structed of noncombustible material and connected to a working flue See page 7 for minimum flue opening WARNING This is a gas fired appliance It uses air oxygen fro...

Page 2: ...and fire box must be cleaned of soot creosote ashes and loose paint by a qualified chimney cleaner Creosote will ignite if highly heated Inspect chimney flue for damage 5 You must operate this log set with a fire placescreeninplace Makesurefireplace screen is closed before running log set 6 This log set is designed to be smoke less If logs ever appear to smoke turn off appliance and call a qualifi...

Page 3: ...ot kit to use remote accessories with this appliance See Acces sories page 17 LOG SETS Model VTLCR18 log set is for use with Model VVTR18 burner set Model VTLCR24 log set is for use with Model VVTR24 burner set Use these log sets only with their corresponding burners UNPACKING CAUTION Do not remove the metal data plates from the burner pan The data plates contain im portant product information 1 R...

Page 4: ...lpreduceheatlossinhomes Homeowners weather strip and caulk around windows and doorstokeepthecoldairoutandthewarmair in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your home needs to breathe Fresh air must enter your home All fuel burning appliances need fresh air for proper com bustion and ventilation Exhaustfans fi...

Page 5: ...raws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _____________ Btu Hr maximum the space can support _____________ Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 95 000 Btu Hr actual amount of Btu Hr used The space in the above example is a confined space ...

Page 6: ...o adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Ventilation Air From Outdoors Provide extra fre...

Page 7: ... must be in stalled only in a solid fuel burning fireplace with a working flue and constructed of non combustible material The charts in Figure 4 indicate technical information regarding the installation of your gas log set Please make sure that all of the specifications shown are applicable be fore installation is attempted The fireplace must include a working flue andventingsystemwiththeminimumo...

Page 8: ...sealant resistant to propane LP gas equipment shutoff valve test gauge connection adjustable crescent wrench or pliers sediment trap tee joint pipe wrench CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to log set If pipe is too small undue loss of press...

Page 9: ...block Tighten with a 7 16 wrench 6 Slip the air restrictor over the 1 8 pipe nipple Apply thread sealant to the male threads and install the rear burner nozzle onto the fitting Tighten with a 9 16 wrench 7 Place the grate assembly over the burner pan Install the rear burner bracket onto the grate with the 2 black Phillips head 10 screws provided Do not tighten at this time see Figure 9 8 Install t...

Page 10: ...e front Close Pipe Nipple Gas Control Valve Manifold Block Figure 11 Installing Gas Control Valve Control Rod INSTALLATION Continued 9 Install valve cover to burner pan using screws provided 10 Install thermocouple pilot and ignitor onto valve cover as shown in Figure 14 Use the provided screws 11 Push the control rod extension onto the D shaped control rod through the cen ter hole in the cover 12...

Page 11: ... ately Tighten or reassemble the loose connection s using pipe joint com pound until burner system is leak free 4 When the burner is tested and leak free observe the individual tongues of flame on the burner Note The burner design includes more ports on the outside of the bar Make sure that all ports are clear and producing flame evenly across the burner Ifanyportsappearblocked clear them by remov...

Page 12: ...ol low the safety information above If you don t smell gas go on to the next step 4 Light a match and lay it on top of the U shaped burner near the edge of the cover on the right side of the pan 5 Slowly turn the gas shutoff valve ON until the burner ignites If the burner doesn t ignite within 10 seconds with the match burning turn the shutoff valve OFF and repeat steps 1 through 4 again WARNING K...

Page 13: ...pressed in for five 5 seconds Note You may be running this log set for the first time after hooking up to gas supply If so the control knob may need to be pressed in for 30 sec onds This will allow air to bleed from the gas system If control knob does not pop up when released contact a qualified service person or gas supplier for repairs 6 With control knob pressed in push down and release ignitor...

Page 14: ...oking sooting excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon soot where flames contact the logs This is especially true with propane LP gas Burner is excessively noisy Note Themovementandcombustionofgas will create low unavoidable levels of noise Burner flame is too low or too high 1 Contact local natural or propane LP gas company 2 Adju...

Page 15: ...inte nance page 17 or replace pilot assembly 5 Hand tighten until snug then tighten 1 4 turn more 6 Replace thermocouple 7 Replace control valve 1 Clean burner orifice 2 Contact local natural or propane LP gas company 3 Replace burner orifice 4 Reconnect leads 1 Adjust pilot flame for approximately 2 blue flame 2 Replace pilot orifice set POSSIBLE CAUSE 1 Ignitor electrode not connected to igni to...

Page 16: ...at top of page OBSERVED PROBLEM Log Set produces a clicking ticking noise just after burner is lit or shut off Log Set produces unwanted odors Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 This is common with most log sets If noise is excessive contact qualified ser vice person 1 Open flue to maximum Stop using odor causing products while log set is running...

Page 17: ...nalreplacementpart s call DESA International s Technical Service Department at 1 800 DESA LOG 1 800 337 2564 WhencallingDESAInternational haveready your name your address modelandserialnumbersofyourfireplace how fireplace was malfunctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the defec tive part to the factory PARTS NOT UNDER WARRANTY Contact ...

Page 18: ...18 901847 VENTED NATURAL GAS LOGS ILLUSTRATED PARTS BREAKDOWN VVTR18 4 19 21 22 20 23 24 25 2 3 8 7 11 10 1 5 6 15 9 14 12 13 26 16 18 5 17 ...

Page 19: ...05 Natural Gas Injector 1 11 901066 01 Brass Air Mixer Natural Gas 1 12 901761 01 1 8 Hex Nipple 1 13 901760 01 Manifold Block 1 14 901751 01 Air Restrictor 1 15 901756 01 Valve Cover 1 16 901056 01 Brass Elbow Flare Fitting 1 17 901058 01 Brass 3 8 FLR x 1 2 FPT Adapter 1 18 101628 01 Gas Line 10 Flex 1 19 901769 02 Ember Bed 1 20 901580 02 Top Log VR 11 VC 1 21 901587 04 Top Log VCR 9 VS 1 22 90...

Page 20: ...20 901847 VENTED NATURAL GAS LOGS ILLUSTRATED PARTS BREAKDOWN VVTR24 4 19 23 21 22 20 24 25 26 2 3 8 7 11 10 1 5 6 15 9 14 12 13 27 16 18 5 17 ...

Page 21: ... Injector 1 11 901066 01 Brass Air Mixer Natural Gas 1 12 901761 01 1 8 Hex Nipple 1 13 901760 01 Manifold Block 1 14 901751 01 Air Restrictor 1 15 901756 01 Valve Cover 1 16 901056 01 Brass Elbow Flare Fitting 1 17 901058 01 Brass 3 8 FLR x 1 2 FPT Adapter 1 18 101628 01 Gas Line 10 Flex 1 19 901769 01 Ember Bed 1 20 901580 02 Top Log VR 11 VC 1 21 901587 04 Top Log VCR 9 VS 1 22 901528 04 Top Lo...

Page 22: ...og set will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA TION OF ANY AND ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO 2 YEARS ON BURNER SYSTEM AND A LIFETIME ON LOGS FROM THE DATE ...

Reviews: