background image

11

104271

OWNER’S MANUAL

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.

Turn control knob clockwise 

Clockwise

to the PILOT position.

2.

Press in control knob and turn clock-
wise 

Clockwise

 to the OFF position.

Shutting Off Burner Only (pilot
stays lit)

Turn control knob clockwise 

Clockwise

 to

the PILOT position.

Thermocouple

Pilot Burner

Ignitor Electrode

Figure 16 - Pilot

OPERATING
HEATER

Continued

 CAUTION: Do not try to ad-

just heating levels by using the
equipment shutoff valve.

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information
page 10, column 3.

2.

Make sure equipment shutoff valve
is fully open.

3.

Turn control knob clockwise 

Clockwise

to the OFF position.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow "B" in the safety in-
formation at the top of column 3,
page 10. If you don’t smell gas, go to
the next step.

5.

Press in control knob and turn coun-
terclockwise 

C-clockwise

 to the PILOT

position. Keep control knob pressed
in for five (5) seconds (see Figure 15).

Note:

 You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.
• If control knob does not pop up

when released, contact a qualified
service person or gas supplier for
repairs.

6.

With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the front of burner. The pilot can
be seen through the glass panel. If
needed, keep pressing ignitor button
until pilot lights.

Note:

 If pilot does not stay lit, refer

to Troubleshooting, pages 13 through
15. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot
with match. To light pilot with match,
see Manual Lighting Procedure
.

OFF

HIGH

PILOT

LOW

IGNITOR

Control Knob

Figure 15 - Control Knob In The OFF
Position

Ignitor Button

1.

Remove front panel (see Figure 10,
page 8).

2.

Follow steps 1 through 5 under Light-
ing Instructions
.

3.

With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.

4.

Keep control knob pressed in for 30
seconds after pilot is lit. After 30 sec-
onds, release control knob. Follow
step 8 under Lighting Instructions.

5.

Replace front panel.

MANUAL LIGHTING

PROCEDURE

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note:

 If pilot goes out, repeat steps

3 through 7.

8.

Turn control knob counterclockwise

C-clockwise

 to the HIGH position. The

main burner should light. Set control
knob to any heat level between HIGH
and LOW. To turn control knob from
HIGH to a lower setting, press in the
control knob and turn counterclock-
wise 

C-clockwise

 .

Note:

 Both HIGH and LOW are

locked positions. You must press in
control knob before turning it from
these positions.

Summary of Contents for Vanguard VN600BA

Page 1: ...st be per formed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice ormaintenancecancause injury or property damage Re fer to this manual for correct installationandoperationalpro cedures For assistance or ad ditional information consult a qualified installer service agency or the gas supplier WARNING This is an unvented gas fi...

Page 2: ...r has an oxygen depletion sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation pages 4 through 6 4 Keep all air openings in front and bot tom of heater clear and free of debris This will insure enough air for proper combustion 5 If heater shuts off do not relight until you provide fresh outside air If heater kee...

Page 3: ...net Grill Guard Glass Panel Front Panel Control Knob Ignitor Button 1 Remove heater from carton 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater UNPACKING PRODUCT FEATURES SAFETY DEVICE This heater has a pilot with an Oxygen DepletionSensing ODS safetyshutoffsys tem The ODS p...

Page 4: ...o breathe Fresh air must enter your home All fuel burning appliances need fresh air for proper com bustion and ventilation Exhaustfans fireplaces clothesdryers and fuel burning appliances draw air from the house to operate You must provide ad equate fresh air for these appliances This will insure proper venting of vented fuel burning appliances PROVIDING ADEQUATE VENTILATION The following are exce...

Page 5: ...Btu Hr of all fuel burning appliances in the space Vent free heater _______________ Btu Hr Gas water heater _______________ Btu Hr Gas furnace _______________ Btu Hr Vented gas heater _______________ Btu Hr Gas fireplace logs _______________ Btu Hr Other gas appliances _______________ Btu Hr Total _______________ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air fro...

Page 6: ... required size of ventilation grills or ducts WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Figure 3 Ventilation Air from Outdoors Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra f...

Page 7: ...ow all local codes LOCATING HEATER This heater is designed to be mounted on a wall WARNING Maintain the mini mumclearancesshowninFigure 4 Ifyoucan providegreaterclear ancesfromfloor ceiling andjoin ing wall CAUTION If you install the heater in a home garage heater pilot and burner must be at least 18 inches above floor locateheaterwheremovingve hicle will not hit it IMPORTANT Vent freeheatersaddmo...

Page 8: ...thick wall shown Solid Wall 1 16 Space Figure 8 Tightening Anchors INSTALLATION Continued Placing Heater On Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place large openings of slots over screwheads Slide heater down until screws are in small portion of slots Figure 11 Installing Bottom Mounting Screw Figure 9 Location Of Keyhole Slots On Back Panel Of Heater R...

Page 9: ...the appliance IMPORTANT Installanequipmentshutoff valve in an accessible location The equip ment shutoff valve is for turning on or shutting off the gas to the appliance CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe 3 8 diameter or greater to allow proper gas volume to heater If pipe is too small undue lo...

Page 10: ... the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 14 Apply mixture of liquid soap and wa ter to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operating Heater pages 10 and 11 Check the rest of the internal joints for leaks 7 Turn off heater see To Turn Off Gas To Appliance page 11 8 Replace front panel ON POSIT O P...

Page 11: ...s supplier for repairs 6 With control knob pressed in push down and release ignitor button This will light pilot The pilot is attached to the front of burner The pilot can be seen through the glass panel If needed keep pressing ignitor button until pilot lights Note If pilot does not stay lit refer to Troubleshooting pages 13 through 15 Also contact a qualified service person or gas supplier for r...

Page 12: ...R ORIFICE Use a vacuum cleaner pressurized air or small soft bristled brush to clean WARNING Turn off heater and let cool before cleaning CAUTION You must keep control areas burner and circu lating air passageways of heater clean Inspect these areas of heater before each use Have heaterinspectedyearlybyaquali fied service person Heater may need more frequent cleaning due to excessive lint from car...

Page 13: ...ect ignitor cable 3 Tighten nut holding piezo ignitor to heater cabinet Nut is located inside heater cabinet at top 4 Replace ignitor cable 5 Replace ignitor 6 Replace piezo ignitor 7 Replace ignitor 1 Turn on gas supply or open equipment shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT position 4 Continue holding down control knob Repeat igniting operatio...

Page 14: ...fter a few hours of operation 1 Turn control knob to LOW position and let warm up for a minute 2 Operate burner until air is removed from line Have gas checked by local natural gas company 3 Observe minimum installation clear ances see Figure 4 page 7 4 Clean burner see Cleaning and Mainte nance page 12 or replace burner orifice 1 This is common with most heaters If noise is excessive contact qual...

Page 15: ...nwindows POSSIBLE CAUSE 1 Heater burning vapors from paint hair spray glues etc See IMPORTANT statement above 2 Gas leak SeeWarning statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak SeeWarning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement...

Page 16: ...16 104271 BLUE FLAME NATURAL GAS HEATER 12 2 12 1 ILLUSTRATED PARTS BREAKDOWN VN600BA 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 17 18 21 22 25 20 24 23 19 26 27 16 ...

Page 17: ...R Deflector Unit 1 10 098271 03 Ignitor Cable 1 11 098249 01 Nut M5 2 12 099440 03 ODS Pilot Assembly 1 12 1 098514 01 Thermocouple 1 12 2 098594 01 Ignitor Electrode 1 13 104263 01 Burner 1 14 099387 05 Pilot Tubing 1 15 104259 03 Injector 1 piece 1 16 NJF 8C Hex Nut 1 17 099415 14 Pressure Regulator 1 18 099462 01 Burner Tubing 1 19 099391 02 Regulator Tubing 1 20 099413 01 Control Valve 1 21 09...

Page 18: ...the address listed on the back page of this manual Send a check for 5 00 payable to DESA International ACCESSORY Purchase this heater accessory from your local dealer If they cannot supply this ac cessory call DESA International s Parts Department at 1 800 972 7879 for referral information You can also write to the ad dress listed on the back page of this manual TECHNICAL SERVICE You may have furt...

Page 19: ...____________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ ___________________________________________________________________________________________...

Page 20: ...his warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagno...