background image

7

104271

OWNER’S MANUAL

Figure 5 - Mounting Screw Locations

Mounting

Screw

Locations

7

/

8

"

Minimum To

Maintain 6"

Clearance
From Wall

3

/

4

"

20 

1

/

4

"

Minimum To

Maintain 3"

Clearance

From Floor

FLOOR

JOINING W

ALL

INSTALLING HEATER TO
WALL

Marking Screw Locations

1.

Determine where you will locate heater.

2.

Mark two mounting screw locations on
wall (see Figure 5).

 WARNING: Maintain minimum

clearances shown in Figure 5. If
you can, provide greater clear-
ances from floor and joining wall.

For convenience and efficiency, install heater

• where there is easy access for operation,

inspection, and service

• in coldest part of room

Figure 4 - Mounting Clearances As Viewed
From Front of Heater

36"

3"

FLOOR

CEILING

Minimum

Minimum T
Of Carpetin
Combustib

6"

Minimum
From
Sides Of
Heater

Right
Side

Left
Side

INSTALLATION

CHECK GAS TYPE

Use only natural gas. If your gas supply is
not natural, do not install heater. Call dealer
where you bought heater for proper type
heater.

INSTALLATION ITEMS

Before installing heater, make sure you have
the items listed below:

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• ground joint union

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

* A CSA/AGA design-certified equipment
shutoff valve with 1/8" NPT tap is an ac-
ceptable alternative to test gauge connec-
tion. Purchase the optional A.G.A. design-
certified equipment shutoff valve from your
dealer. See Accessory, page 18.

 WARNING: A qualified ser-

vice person must install heater.
Follow all local codes.

LOCATING HEATER

This heater is designed to be mounted on a
wall.

 WARNING: Maintain the mini-

mum clearances shown in Figure
4. If you can, provide greater clear-
ances from floor, ceiling, and join-
ing wall.

 CAUTION: If you install the

heater in a home garage
• heater pilot and burner must

be at least 18 inches above
floor

• locate heater where moving ve-

hicle will not hit it

IMPORTANT:

 Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation, 
pages 4 through 6.

 WARNING: Never install the

heater
• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the heater

• as a fireplace insert
• in high traffic areas
• in windy or drafty areas

Minimum To
Top Surface
Of Carpeting,
Tile Or Other
Combustible
Material

Continued

 CAUTION: This heater cre-

ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.

NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

Summary of Contents for Vanguard VN600BA

Page 1: ...st be per formed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice ormaintenancecancause injury or property damage Re fer to this manual for correct installationandoperationalpro cedures For assistance or ad ditional information consult a qualified installer service agency or the gas supplier WARNING This is an unvented gas fi...

Page 2: ...r has an oxygen depletion sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation pages 4 through 6 4 Keep all air openings in front and bot tom of heater clear and free of debris This will insure enough air for proper combustion 5 If heater shuts off do not relight until you provide fresh outside air If heater kee...

Page 3: ...net Grill Guard Glass Panel Front Panel Control Knob Ignitor Button 1 Remove heater from carton 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater UNPACKING PRODUCT FEATURES SAFETY DEVICE This heater has a pilot with an Oxygen DepletionSensing ODS safetyshutoffsys tem The ODS p...

Page 4: ...o breathe Fresh air must enter your home All fuel burning appliances need fresh air for proper com bustion and ventilation Exhaustfans fireplaces clothesdryers and fuel burning appliances draw air from the house to operate You must provide ad equate fresh air for these appliances This will insure proper venting of vented fuel burning appliances PROVIDING ADEQUATE VENTILATION The following are exce...

Page 5: ...Btu Hr of all fuel burning appliances in the space Vent free heater _______________ Btu Hr Gas water heater _______________ Btu Hr Gas furnace _______________ Btu Hr Vented gas heater _______________ Btu Hr Gas fireplace logs _______________ Btu Hr Other gas appliances _______________ Btu Hr Total _______________ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air fro...

Page 6: ... required size of ventilation grills or ducts WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Figure 3 Ventilation Air from Outdoors Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra f...

Page 7: ...ow all local codes LOCATING HEATER This heater is designed to be mounted on a wall WARNING Maintain the mini mumclearancesshowninFigure 4 Ifyoucan providegreaterclear ancesfromfloor ceiling andjoin ing wall CAUTION If you install the heater in a home garage heater pilot and burner must be at least 18 inches above floor locateheaterwheremovingve hicle will not hit it IMPORTANT Vent freeheatersaddmo...

Page 8: ...thick wall shown Solid Wall 1 16 Space Figure 8 Tightening Anchors INSTALLATION Continued Placing Heater On Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place large openings of slots over screwheads Slide heater down until screws are in small portion of slots Figure 11 Installing Bottom Mounting Screw Figure 9 Location Of Keyhole Slots On Back Panel Of Heater R...

Page 9: ...the appliance IMPORTANT Installanequipmentshutoff valve in an accessible location The equip ment shutoff valve is for turning on or shutting off the gas to the appliance CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe 3 8 diameter or greater to allow proper gas volume to heater If pipe is too small undue lo...

Page 10: ... the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 14 Apply mixture of liquid soap and wa ter to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operating Heater pages 10 and 11 Check the rest of the internal joints for leaks 7 Turn off heater see To Turn Off Gas To Appliance page 11 8 Replace front panel ON POSIT O P...

Page 11: ...s supplier for repairs 6 With control knob pressed in push down and release ignitor button This will light pilot The pilot is attached to the front of burner The pilot can be seen through the glass panel If needed keep pressing ignitor button until pilot lights Note If pilot does not stay lit refer to Troubleshooting pages 13 through 15 Also contact a qualified service person or gas supplier for r...

Page 12: ...R ORIFICE Use a vacuum cleaner pressurized air or small soft bristled brush to clean WARNING Turn off heater and let cool before cleaning CAUTION You must keep control areas burner and circu lating air passageways of heater clean Inspect these areas of heater before each use Have heaterinspectedyearlybyaquali fied service person Heater may need more frequent cleaning due to excessive lint from car...

Page 13: ...ect ignitor cable 3 Tighten nut holding piezo ignitor to heater cabinet Nut is located inside heater cabinet at top 4 Replace ignitor cable 5 Replace ignitor 6 Replace piezo ignitor 7 Replace ignitor 1 Turn on gas supply or open equipment shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT position 4 Continue holding down control knob Repeat igniting operatio...

Page 14: ...fter a few hours of operation 1 Turn control knob to LOW position and let warm up for a minute 2 Operate burner until air is removed from line Have gas checked by local natural gas company 3 Observe minimum installation clear ances see Figure 4 page 7 4 Clean burner see Cleaning and Mainte nance page 12 or replace burner orifice 1 This is common with most heaters If noise is excessive contact qual...

Page 15: ...nwindows POSSIBLE CAUSE 1 Heater burning vapors from paint hair spray glues etc See IMPORTANT statement above 2 Gas leak SeeWarning statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak SeeWarning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement...

Page 16: ...16 104271 BLUE FLAME NATURAL GAS HEATER 12 2 12 1 ILLUSTRATED PARTS BREAKDOWN VN600BA 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 17 18 21 22 25 20 24 23 19 26 27 16 ...

Page 17: ...R Deflector Unit 1 10 098271 03 Ignitor Cable 1 11 098249 01 Nut M5 2 12 099440 03 ODS Pilot Assembly 1 12 1 098514 01 Thermocouple 1 12 2 098594 01 Ignitor Electrode 1 13 104263 01 Burner 1 14 099387 05 Pilot Tubing 1 15 104259 03 Injector 1 piece 1 16 NJF 8C Hex Nut 1 17 099415 14 Pressure Regulator 1 18 099462 01 Burner Tubing 1 19 099391 02 Regulator Tubing 1 20 099413 01 Control Valve 1 21 09...

Page 18: ...the address listed on the back page of this manual Send a check for 5 00 payable to DESA International ACCESSORY Purchase this heater accessory from your local dealer If they cannot supply this ac cessory call DESA International s Parts Department at 1 800 972 7879 for referral information You can also write to the ad dress listed on the back page of this manual TECHNICAL SERVICE You may have furt...

Page 19: ...____________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ ___________________________________________________________________________________________...

Page 20: ...his warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagno...