background image

15

104637

OWNER’S MANUAL

 WARNING: Make sure the se-

lector switch is in the OFF posi-
tion when you are away from home
for long periods of time. Heater
will come on automatically with
selector switch in the ON position.

TO TURN OFF GAS

TO APPLIANCE

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 6 under Light-
ing Instructions
, page 14.

2.

Depress control knob and light pilot
with match.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow steps 9 through 11 under Light-
ing Instructions
, pages 14 and 15.

OPERATING
FIREPLACE

Continued

Shutting Off Heater

1.

Turn control knob clockwise  
to the OFF position.

2a. Set selector switch in the OFF position.

2b.

If Using Optional Hand-Held Re-
mote:

 Set selector switch in the OFF

position to prevent draining battery.

Shutting Off Burner Only (pilot
stays lit)

You may shut off the burner and keep the
pilot lit by doing one of the following:

• Turn control knob clockwise  

to the PILOT position.

• Use remote control manual OFF button.

• Set selector switch in the OFF position.

 CAUTION: Do not try to adjust

heating levels by using the equip-
ment shutoff valve.

10. Wait one minute and switch selector

switch to the ON position to light
burner.

11. Set flame adjustment knob to any

level between HI and LO.

OPTIONAL REMOTE

OPERATION

NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See 

Lighting

Instructions on page 14.

1.

After lighting, let pilot flame burn for
about one minute. This is required be-
fore the burner will turn on. Turn con-
trol knob to ON position. Adjust flame
adjustment knob anywhere between
HI and LO. Slide the selector switch
to the REMOTE position. 

NOTE:

 The

burner may light if hand-held remote
ON button was on when selector
switch was last turned off. You can
now turn the burner on and off with
the hand-held remote control unit.

IMPORTANT: 

Do not leave the se-

lector switch in the REMOTE posi-
tion when the pilot is not lit. This will
drain the battery.

IMPORTANT:

 Be sure to press the

ON/OFF buttons on the hand held
remote control unit for up to 3 sec-
onds to assure proper operation.

GHRC Series Operation:

2a. Press the ON/OFF button to turn the

burner on and off (see Figure 30).
When turning burner off, the pilot
will remain lit.

GHRCT Series Operation:

2b. Press the AUTO/ON/OFF button on

the hand-held remote control (see
Figure 31, page 16). The lights to the
left of the button will show AUTO,
ON, or OFF.
• In the ON mode, the burners will

ignite. The heater is in manual
mode when ON is lit.

Note:

 All remote control accessories must

be purchased separately (see Accessories,
pages 22 and 23). Follow instructions in-
cluded with the remote control.

Thermostat Control Operation

(Optional GHRCT Series Only) The ther-
mostat control setting on the remote con-
trol unit can be set to any comfort level
between WARMER and COOLER. The
burners will turn on and off automati-
cally to maintain the comfort level you
select. The ideal comfort setting will vary
by household depending upon the amount
of space to be heated, the output of the
central heating system, etc.

For wall thermostat operation, follow
instructions supplied with thermostat
accessory GWMT1. For wall switch op-
eration, follow instructions supplied with
GWMS2.

Figure 30 - GHRC Hand-Held Remote
Control Unit

Turns Burner
On and Off

O

FF

PILO

T

O

N

L O

I H

ON
OFF
REMOTE

Figure 29 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for
Remote Operation

Selector Switch in Remote Position
(Optional Remote Control)

Control Knob in
On Position

Flame Adjustment Knob

Summary of Contents for Vanguard VCGF30PR

Page 1: ...n and operational pro cedures For assistance or addi tional information consult a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxy ge...

Page 2: ...structions in Cleaning and Main tenance page 21 9 Before using furniture polish wax car pet cleaner or similar products turn heater off If heated the vapors from these products may create a white pow...

Page 3: ...e 4 Remove fireplace hood from carton insert 5 Check all items for any shipping dam age If damaged promptly inform dealer where you bought fireplace Figure 1 Log Base Assembly Figure 2 Fireplace REMOT...

Page 4: ...his vent free fireplace is clean burning It requiresnooutsideventing Thereisnoheat loss out a vent or up a chimney Heat is generatedbybothrealisticflamesandglow ing embers When used without the blower...

Page 5: ...____ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual am...

Page 6: ...the ceiling and one within 12 of the floor Connecttheseitemsdirectlytotheoutdoors orspacesopentotheoutdoors Thesespaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANS Z2...

Page 7: ...otted screwdriver NOTICE This heater is intended foruseassupplementalheat Use this heater along with your pri mary heating system Do not in stall this heater as your primary heat source If you have a...

Page 8: ...STALLATION Continued 4 Place hearth base accessory against wall at installation location Cut an ac cess hole in hearth top to run gas line to fireplace see Figure 9 Make sure to locate access hole so...

Page 9: ...16 17 3 4 1 Frame in rough opening Use dimen sions shown in Figure 13 for the rough opening If installing in a corner use dimen sions shown in Figure 14 for the rough opening The height is 33 which i...

Page 10: ...IREPLACE LOCATION Installation Items Needed Before installing fireplace make sure you have the items listed below external regulator supplied by installer piping check local codes sealant resistant to...

Page 11: ...replace see Figure 21 5 Check all gas connections for leaks See Checking Gas Connections page 12 6 Replace log base assembly back into fireplace Feed flexible gas line into fire place base area while...

Page 12: ...essure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve control valve and equipment shutoff valve from gas sup ply...

Page 13: ...is seated into U shaped cutout in cen ter of chassis see Figure 24 IMPORTANT Make sure log does not cover any burner ports 2 Install front window assembly to front of fireplace by slipping bottom wind...

Page 14: ...area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electr...

Page 15: ...he burner may light if hand held remote ON button was on when selector switch was last turned off You can now turn the burner on and off with the hand held remote control unit IMPORTANT Do not leave t...

Page 16: ...ote control unit must be near the heater Do not keep the hand held remote control unit too close to the heater The thermostat on the hand held remote control unit will heat up too quickly and turn the...

Page 17: ...Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Re...

Page 18: ...irements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local propane LP gas company 3 Observe minimum...

Page 19: ...ilate room Stop using odor causing products while fire place is running 2 Locate and correct all leaks see Check ing Gas Connections page 12 1 Open window and or door for ventilation 2 Contact local p...

Page 20: ...ational have ready your name and address model and serial numbers of your heater how heater was malfunctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to retur...

Page 21: ...talyst Use a brush with soft bristles a vacuum with a brush attach ment orcompressedairtoremoveloosedirt debris and dust After cleaning install the catalytic filter back to the unit CLEANING BURNER IN...

Page 22: ...finished GM102W Series Off White Paint Shown with optional base and laminate hearth and mantel trim accessories Dimensions WxHxD 56 3 4 x 48 x 20 3 4 HARDWOOD HEARTH BASE G3000F Series Walnut Finished...

Page 23: ...chair RECEIVER AND HAND HELD REMOTE CONTROL KIT GHRC SERIES Allowsthegaslogheatertobeturnedonand off by using a hand held remote control WALL MOUNT THERMOSTAT SWITCH GWMT1 Not Shown The desired comfo...

Page 24: ...UNVENTED PROPANE LP GAS FIREPLACE ILLUSTRATED PARTS BREAKDOWN REMOTE READY CATALYTIC MODEL VCGF30PR 17 4 O F F P I L O T O N H I L O 8 12 26 7 6 4 3 2 1 5 9 14 13 25 15 16 21 11 10 19 19 20 19 23 24 2...

Page 25: ...8265 02 Elbow Male 1 15 103782 01 Valve Bracket 1 16 103781 02 Gas Control Valve 1 17 098271 03 Ignitor Cable 1 18 102445 01 Piezo Ignitor 1 19 098304 01 Screw 15 20 099998 01 Switch 1 21 104241 01 Re...

Page 26: ...26 104637 UNVENTED PROPANE LP GAS FIREPLACE ILLUSTRATED PARTS BREAKDOWN FIREPLACE VCGF30PR 4 26 24 25 24 11 14 8 14 3 14 2 22 21 23 23 10 17 13 5 16 15 18 9 1 27 19 6 7 28 5 5 20 12...

Page 27: ...PPH 10 24 x 50 2 10 104717 01 Firebox Top Assembly 1 11 101346 01CK Outer Base 1 12 104638 01 Firebox Wrapper 1 13 101514 01CK Cover 1 14 M11084 26 Hex Screw 10 45 15 104242 01CK Bottom Louvered Door...

Page 28: ...to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER E...

Reviews: