16

104637

UNVENTED PROPANE/LP GAS FIREPLACE

®

Figure 32 - Correct Pilot Flame Pattern

Figure 33 - Incorrect Pilot Flame Pattern

Check pilot flame pattern and burner flame
patterns often.

PILOT FLAME PATTERN

Figure 32 shows a correct pilot flame pattern.
Figure 33 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not prop-
erly heating the thermocouple. When the
thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown
in Figure 33

• turn heater off (see To Turn Off Gas to

Appliance, page 15)

• see Troubleshooting, pages 17 through 19

INSPECTING
BURNERS

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the
holes in the fitting at the burner entrance.
These holes may become blocked with dust
or lint. Periodically inspect these holes for
any blockage and clean if needed. Blocked
air holes will create soot.

MAIN BURNER

Periodically inspect all burner flame holes
with the heater running. All slotted burner
flame holes should be open with yellow
flame present. All round burner flame holes
should be open with a small blue flame
present. Some burner flame holes may be-
come blocked by debris or rust, with no flame
present. If so, turn off heater and let cool.
Either remove blockage or replace burner.
Blocked burner flame holes will create soot.

OPERATING
FIREPLACE

Continued

• In the AUTO mode, the thermostat

in the hand-held remote unit con-
trols the room temperature. To in-
crease the room temperature, press
the top arrow of the TEMP button.
To lower the room temperature,
press the bottom arrow of the
TEMP button. At higher settings
the heater will run longer.

IMPORTANT:

 This remote control

has been specially engineered to
take an air temperature sample ev-
ery minute in the auto mode. It will
not respond immediately to the
temperature setting being turned
up or down.

IMPORTANT:

 The hand-held re-

mote control unit must be near the
heater. Do not keep the hand-held
remote control unit too close to the
heater. The thermostat on the
hand-held remote control unit will
heat up too quickly and turn the
heater off.

3.

To turn the burner off, press the
AUTO/ON/OFF button until OFF
lights. The pilot will remain lit.

IMPORTANT:

 To turn the pilot off,

manually turn the control knob on the
heater to the OFF position.

Shows Temperature
Setting

Increases Room
Temperature in AUTO
Mode

Decreases Room
Temperature in AUTO
Mode

Turns Burners On or Off
and Allows You to
Choose the Auto Setting

The Log Heater will
Automatically Cycle
between Pilot and the
Heat Setting that has
been Selected

Figure 31 - Thermostat Hand-Held Remote Control Unit Selections
(GHRCT Series Only)

 OPTIONAL BLOWER

OPERATION

Locate the blower switch by opening lower
louver on fireplace. Blower switch is lo-
cated at lower left inside louver door.

The GA3700TA Series thermostat-con-
trolled blower has a variable speed con-
trol with an ON/OFF switch. The blower
will start when the thermostat senses a
sufficient increase in firebox temperature.
The GA3700 variable speed blower also
has an ON/OFF switch built into the vari-
able speed control.

Note for GA3700TA Series Only: 

If

you are using GA3700TA series blower,
your fireplace and blower will not turn on
and off at the same time. The fireplace
may run for several minutes before the
blower turns on. After the heater modu-
lates to the pilot position, the blower will
continue to run. The blower will shut off
after the firebox temperature decreases.

Note:

 It is safe to operate fireplace with

blower turned off. However, the blower helps
distribute heated air from the fireplace.

Follow installation instructions included
with the blower accessory.

 WARNING: This fireplace has

a three-prong, grounded electri-
cal plug. This plug helps protect
you against electrical shock. Only
connect plug to a properly
grounded, three-prong recep-
tacle. Do not cut or remove the
grounding prong from this plug.

Pilot Burner

Thermocouple

Pilot Burner

Thermocouple

Summary of Contents for Vanguard VCGF30PR

Page 1: ...n and operational pro cedures For assistance or addi tional information consult a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxy ge...

Page 2: ...structions in Cleaning and Main tenance page 21 9 Before using furniture polish wax car pet cleaner or similar products turn heater off If heated the vapors from these products may create a white pow...

Page 3: ...e 4 Remove fireplace hood from carton insert 5 Check all items for any shipping dam age If damaged promptly inform dealer where you bought fireplace Figure 1 Log Base Assembly Figure 2 Fireplace REMOT...

Page 4: ...his vent free fireplace is clean burning It requiresnooutsideventing Thereisnoheat loss out a vent or up a chimney Heat is generatedbybothrealisticflamesandglow ing embers When used without the blower...

Page 5: ...____ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual am...

Page 6: ...the ceiling and one within 12 of the floor Connecttheseitemsdirectlytotheoutdoors orspacesopentotheoutdoors Thesespaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANS Z2...

Page 7: ...otted screwdriver NOTICE This heater is intended foruseassupplementalheat Use this heater along with your pri mary heating system Do not in stall this heater as your primary heat source If you have a...

Page 8: ...STALLATION Continued 4 Place hearth base accessory against wall at installation location Cut an ac cess hole in hearth top to run gas line to fireplace see Figure 9 Make sure to locate access hole so...

Page 9: ...16 17 3 4 1 Frame in rough opening Use dimen sions shown in Figure 13 for the rough opening If installing in a corner use dimen sions shown in Figure 14 for the rough opening The height is 33 which i...

Page 10: ...IREPLACE LOCATION Installation Items Needed Before installing fireplace make sure you have the items listed below external regulator supplied by installer piping check local codes sealant resistant to...

Page 11: ...replace see Figure 21 5 Check all gas connections for leaks See Checking Gas Connections page 12 6 Replace log base assembly back into fireplace Feed flexible gas line into fire place base area while...

Page 12: ...essure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve control valve and equipment shutoff valve from gas sup ply...

Page 13: ...is seated into U shaped cutout in cen ter of chassis see Figure 24 IMPORTANT Make sure log does not cover any burner ports 2 Install front window assembly to front of fireplace by slipping bottom wind...

Page 14: ...area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electr...

Page 15: ...he burner may light if hand held remote ON button was on when selector switch was last turned off You can now turn the burner on and off with the hand held remote control unit IMPORTANT Do not leave t...

Page 16: ...ote control unit must be near the heater Do not keep the hand held remote control unit too close to the heater The thermostat on the hand held remote control unit will heat up too quickly and turn the...

Page 17: ...Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Re...

Page 18: ...irements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local propane LP gas company 3 Observe minimum...

Page 19: ...ilate room Stop using odor causing products while fire place is running 2 Locate and correct all leaks see Check ing Gas Connections page 12 1 Open window and or door for ventilation 2 Contact local p...

Page 20: ...ational have ready your name and address model and serial numbers of your heater how heater was malfunctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to retur...

Page 21: ...talyst Use a brush with soft bristles a vacuum with a brush attach ment orcompressedairtoremoveloosedirt debris and dust After cleaning install the catalytic filter back to the unit CLEANING BURNER IN...

Page 22: ...finished GM102W Series Off White Paint Shown with optional base and laminate hearth and mantel trim accessories Dimensions WxHxD 56 3 4 x 48 x 20 3 4 HARDWOOD HEARTH BASE G3000F Series Walnut Finished...

Page 23: ...chair RECEIVER AND HAND HELD REMOTE CONTROL KIT GHRC SERIES Allowsthegaslogheatertobeturnedonand off by using a hand held remote control WALL MOUNT THERMOSTAT SWITCH GWMT1 Not Shown The desired comfo...

Page 24: ...UNVENTED PROPANE LP GAS FIREPLACE ILLUSTRATED PARTS BREAKDOWN REMOTE READY CATALYTIC MODEL VCGF30PR 17 4 O F F P I L O T O N H I L O 8 12 26 7 6 4 3 2 1 5 9 14 13 25 15 16 21 11 10 19 19 20 19 23 24 2...

Page 25: ...8265 02 Elbow Male 1 15 103782 01 Valve Bracket 1 16 103781 02 Gas Control Valve 1 17 098271 03 Ignitor Cable 1 18 102445 01 Piezo Ignitor 1 19 098304 01 Screw 15 20 099998 01 Switch 1 21 104241 01 Re...

Page 26: ...26 104637 UNVENTED PROPANE LP GAS FIREPLACE ILLUSTRATED PARTS BREAKDOWN FIREPLACE VCGF30PR 4 26 24 25 24 11 14 8 14 3 14 2 22 21 23 23 10 17 13 5 16 15 18 9 1 27 19 6 7 28 5 5 20 12...

Page 27: ...PPH 10 24 x 50 2 10 104717 01 Firebox Top Assembly 1 11 101346 01CK Outer Base 1 12 104638 01 Firebox Wrapper 1 13 101514 01CK Cover 1 14 M11084 26 Hex Screw 10 45 15 104242 01CK Bottom Louvered Door...

Page 28: ...to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER E...