                                                                                                        - 8 -                                         

For more information, visit www.desatech.com 

MANTELS 
 

A mantel may be installed if desired (see figure 18 & 19), 
Woodwork such as wood trims, mantels, or any other 
combustible material projecting from the front face must not 
be placed within 9 inches of the fireplace opening (and within 
6 inches of the top louver opening).  Combustible materials 
above 9 inches and projecting more than 1-1/2 inches from the 
fireplace must not be placed less than 12 inches from the top 
opening of the fireplace (NFPA STD 211, Sec. 7-3.3.3). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 

OPERATING GUIDELINES AND MAINTENANCE 

INSTRUCTIONS 

GLASS DOORS 

Glass doors are optional with the fireplace.  When the 
fireplace is in operation, doors must in FULLY OPENED or 
FULLY CLOSED position only or a fire hazard may be 
created (see figure 20). 
A fireplace equipped with glass doors operates much 
differently than a fireplace with an open front.  A fireplace 
with glass doors has a limited amount of air for combustion.  
Excessive heat within the fireplace can result if too large a fire 
is built or if the combustion air gate is not completely open.  
The following tips should be followed to assure that both the 
fireplace and the glass door retain their beauty and function 
properly.  Both the flue damper and the glass doors must be 
fully opened before starting the fire.  This will provide 
sufficient combustion air and maintain safe temperatures in 
the firebox. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
IMPORTANT:

 The glass must be allowed to warm slowly 

and evenly.  The tempered glass will withstand a gradual 
temperature rise to 550 degrees Fahrenheit, which is more 
than a normal fire will generate.  Such materials as pitch/wax 
laden logs, very dry mill end lumber, and large amounts of 
paper or cardboard boxes can create an excessively hot fire 
and should not be burned in this fireplace.  Always keep the 
fire well back from the doors and never allow flames to 
contact the glass. 
 
 
 
 
 
 
 

 
CLEANING THE GLASS 

 
Clean the glass with any commercial glass cleaner or soap and 
water.  Do not use any abrasive material to clean the glass.  Do 
not clean the glass with any cool water if the glass is still hot 
from the fire and smoke. 

Figure 20               GLASS DOORS 

WARNING

: Fireplaces equipped with glass doors

should be operated only with doors fully opened or doors
fully closed.  Doors, if left partly open, may draw gas and
flame out of the fireplace opening creating risks of both
fire and smoke. 

 

Figure 19      MANTEL CLEARANCE 

Figure 18         MANTEL CLEARANCE 

Summary of Contents for (V)C36LH

Page 1: ...nted gas log approved to ANS Z21 60 Z21 84 or RGA 2 72 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard A DESA hood must be installed when using a vent free gas l...

Page 2: ...DE AIR KIT INSTALLATION PG 3 7 FAN BLOWER KIT ASSEMBLY PG 4 8 CHIMNEY PIPE AND OFFSET INSTALLATION PG 4 5 9 FIRESTOP SPACERS PG 5 10 FLASHING AND TERMINATION PG 6 7 11 FINISHING YOUR FIREPLACE PG 7 12...

Page 3: ...l to Opening of unit 12 minimum Top Spacers 0 minimum Mantel Clearances see page 8 Mantels Chimney Outer Pipe Surfaces 1 minimum MINIMUM MAXIMUM CHIMNEY HEIGHT The minimum height of the chimney measur...

Page 4: ...the fireplace HEARTH EXTENSION A hearth extension projecting a minimum of 16 in front of and a minimum of 8 beyond each side of the fireplace opening is required to protect combustible floor construct...

Page 5: ...nd a wire spacer The pipe sections must be assembled independently as the chimney is installed When connecting chimney directly to the fireplace the inner flue pipe section must be installed first wit...

Page 6: ...pipe passes through a framed opening into an attic space the firestop must be placed into an attic floor as shown in figure 11 PENETRATING THE ROOF OFFSET RISE A B 48 36 24 18 12 4 3 8 16 3 8 9 3 4 2...

Page 7: ...ASHING INSTALLATION V6F 8DM or V12F 8DM Determine the flashing to be used with the roof opening chart Slide flashing over pipe until base is flat against roof Replace as many shingles as needed to cov...

Page 8: ...prevent smoke spillage from one termination to another We suggest that terminations be separated at least 24 inches center to center and stacked at vertical height difference of 18 inches see figure 1...

Page 9: ...owed to assure that both the fireplace and the glass door retain their beauty and function properly Both the flue damper and the glass doors must be fully opened before starting the fire This will pro...

Page 10: ...for fitting connection see figure 22 NOTE Secure incoming gas line to wood framing to provide rigidity for threaded end STEP 4 Repack insulation around gas line and into sleeve opening Seal any gaps b...

Page 11: ...ure 23 Pulling the handle out will free the outside air door to open Pushing the handle in will lock the door close FOR FURTHER OPERATING GUIDELINES INSTRUCTIONS AND WARRANTY INFORMATION PLEASE REFER...

Page 12: ...502 BAG POLY 1 17a 106651 01 PANEL CLOSURE SMOOTH 1 51 16901 STRAPPING 7 16 10 5 18 106687 01 COLLAR DAMPER CAN 1 52 20023 COLLAR STARTER 1 19 106691 01 ROD SCREEN 2 53 20027 RETAINER REFRACTORY 2 20...

Page 13: ...11a For more information visit www desatech com ILLUSTRATED PARTS...

Page 14: ...12 For more information visit www desatech com REPLACEMENT PARTS ACCESSORY PARTS VC36H VC36LH C36H C36LH VC36 I VC36L I CWC36C C36 I C36L I...

Reviews: