INTRODUCTION

SAFETY INFORMATION

BEFORE YOU BEGIN

INTRODUCTION

Model V3610ST series is a wood-burning fireplace intended and
approved for installation in either residential homes or buildings of
standard construction. This fireplace system requires the utilization
of a DESA 10" double wall, snap-lock flue pipe system.

GLASS DOORS

 are optional with this fireplace and come in

different styles. For further details (see page 14).

BE SURE TO CHECK WITH YOUR LOCAL BUILDING
CODES FOR AREA REQUIREMENTS BEFORE IN-
STALLING THIS FIREPLACE.

SAFETY INFORMATION

1.

This fireplace reaches high temperatures. Keep children and
adults away from hot surfaces to avoid burns or clothing igni-
tion. Fireplace will remain hot for a time after shutdown. Al-
low surfaces to cool before touching.

2.

Carefully supervise young children when they are in the room
with fireplace.

3.

Do not modify this fireplace under any circumstances. Any
parts removed for servicing must be replaced prior to operat-
ing fireplace.

4.

Let fireplace cool before servicing, repairing, or installing ac-
cessories. Only a qualified service person should install, ser-
vice, or repair this fireplace. Have fireplace inspected annu-
ally by a qualified service person.

5.

Keep the area around your fireplace clear of combustible mate-
rials, gasoline, and other flammable vapor and liquids. Do not
operate fireplace where these are used or stored. Do not place
items such as clothing or decorations on or around fireplace.

6.

Do not connect this fireplace to a chimney system other than a
DESA chimney system.

7.

Due to high temperatures, do not locate this fireplace in high
traffic areas or near furniture and draperies.

8.

Provide adequate clearances around air openings into the com-
bustion chamber. NEVER obstruct the front openings of the
fireplace or the flow of combustion and ventilation air. Install
in an area providing ventilation and adequate combustion air.

IMPORTANT: Read this owner’s manual carefully and
completely before trying to assemble, operate, or service
this fireplace. Improper use of this fireplace can cause
serious injury or death from burns, and fire.

BEFORE YOU BEGIN

Before beginning the installation of your fireplace, read these
instructions thoroughly. This DESA fireplace and its approved
components are safe when installed according to this installation
manual, and operated as recommended by DESA. Unless you use
DESA approved components tested for this fireplace, YOU MAY
CAUSE A FIRE HAZARD!

The DESA warranty will be voided by, and DESA disclaims any
responsibility for the following actions:

A) Modification of the fireplace or any of the components manufac-

tured by DESA unless otherwise permitted in writing by DESA.

B) The use of a fireplace insert or any component part not ap-

proved by DESA in combination with DESA fireplace.

C) Installation and/or operation in a manner other than instructed

in this manual.

D) The burning of any other fuel not tested or approved by DESA

in this wood burning fireplace.

PROPER INSTALLATION is the most important step in ensuring
a safe and continuous operation of this fireplace. Although ground-
ing may not be required by code in your area, it must be electrically
grounded in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70-1990.

This fireplace is intended for installation in accordance with the
National Fire Protection Association Standard for Chimneys, Fire-
places, Vents and Solid-Fuel Burning Fireplaces, NFPA 211
, and in
accordance with codes such as the BOCA Basic /National Code, the
Standard Mechanical Code, and the Uniform Building Code.

THIS FIREPLACE IS NOT INTENDED TO BE USED AS
A PRIMARY SOURCE OF HEAT.

NOTE:

 Installation and repair should be done by a qualified

installer familiar with the fireplace. The fireplace and chimney
system should be inspected and cleaned before use and periodically
thereafter especially during heating season to prevent the excessive
buildup of soot and creosote and to ensure a safe operating system.

Summary of Contents for THE SAVANNAH V3610ST

Page 1: ...is or any other appliance WARNING Improper installation adjust ment alteration service or maintenance cancauseinjuryorpropertydamage orloss of life Refer to this manual for correct instal lation and o...

Page 2: ...Dia 38 7cm O D 10 Dia I D 25 4cm 24 60 9cm 6 15 2cm 52 3 4 134cm 17 40 6cm 10 1 4 26cm 11 1 4 28 5cm 7 177mm Outside Air Left Side View Front View Top View Gas Line Conduit 17 3 16 43 6cm 12 30 4cm 1...

Page 3: ...rea providing ventilation and adequate combustion air IMPORTANT Read this owner s manual carefully and completelybeforetryingtoassemble operate orservice this fireplace Improper use of this fireplace...

Page 4: ...all Figure 2 Plan View of Common Location CLEARANCES MINIMUM CLEARANCES TO COMBUSTIBLES Back 1 Min Adjacent Wall 12 Min Chimney Outer Pipe Surfaces 2 Min Bottom Of Fireplaces To Floor 0 Min CAUTION Do...

Page 5: ...dtofityourrequiredplatformheight see Figure 8 The ember protector should be made of 28 gauge minimum galvanized sheet metal to prevent corrosion Figure 4 Mantel Clearances Figure 5 Mantel Clearances F...

Page 6: ...e manufacturer or supplier or the noncombustible material Theminimumrequiredthicknessforanymaterialcouldbeobtained by the following formula K factor x 1 0 inch Thickness required 0 84 If the hearth ex...

Page 7: ...vide rigidity for threaded end 4 Repack insulation around gas line and into sleeves openings Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace ce...

Page 8: ...essary to add screws to keep vertical or angled chimney runs together Figure 16 Pipe Connection WARNING Theopeningaroundthestartercollaron topofthefireplacemustneverbeobstructed Neveruse blown insulat...

Page 9: ...pace ELBOW OFFSET INSTALLATION Chimney weight above offset rests on return elbow Straps must be secured with nails to rafters or joists see Figure 19 Figure 19 Elbow Offset Figure 20 Chimney Supports...

Page 10: ...run with 1 elbow set and 25 feet minimum for a run with 2 elbow sets A set consists of one starter elbow and one return elbow Uncommon circumstances such as neighboring hills tall trees or strong win...

Page 11: ...ed for the pitch of your particular roof Figure 25 Roof Opening FINISHING YOUR CHIMNEY SYSTEM Maximum Chimney Height Cont Chimney Maintenance MINIMUM HEIGHT 15 FT 4 5m MAXIMUM HEIGHT CHASE TERMINATION...

Page 12: ...many shingles as needed to cover exposed area and flashing base Secure in position by nailing through shingles DO NOT NAIL THROUGH FLASHING CONE Figure 26 Flashing Installation Storm Collar Installati...

Page 13: ...proper clearances are adhered to and the fireplaceopeningsarenotobstructedinanyway RefertoClearances page 5 and Figure 30 Use only heat resistant noncombustible mortar or adhesive when securing facing...

Page 14: ...ir and maintain safe temperatures in the firebox If operating with glass doors closed do so at this time Do not operate with doors par tially open Doors must be fully open or fully closed The glass mu...

Page 15: ...load the grate or obstruct the required air space beneath it Always keep ashes from building up under the grate WARNING RISK OF FIRE Replace grate with DESA model 3610ST GR grate only Never obstruct t...

Page 16: ...tedwiththisfireplacemayconstituteafirehazardandwillvoidtheDESAwarranty Storm Collar Storm Collar Comes With Wire Spacer Starter Elbow Return Elbow Vent Hood Vent Plaster Collar HEARTH EXTENSION KIT HE...

Page 17: ...ompleted College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 00...

Page 18: ...55253C 18 For more information visit www desatech com For more information visit www desatech com 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Page 19: ..._________________________________________________________ _______________________________________________________________________________________________ ______________________________________________...

Page 20: ...55253C 20 For more information visit www desatech com For more information visit www desatech com 55253 Rev C 03 03 NOT A UPC 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 55253...

Reviews: