Chase Installation

Instructions for chase installations are included with the chase style
termination chosen. However, it is worthy to mention here that in a
multiple chase installation, provide adequate distance between
terminations, or smoke spillage from one termination to another
may occur. We suggest terminations be separated at least 30 inches
center to center, and stacked at a vertical height difference of 18
inches vertically from one termination to the other (see Figure 29).

Figure 29 - Chase Clearances

INSTALLING FIREPLACE FACING

Any noncombustible material may be used for facing (glass, tile,
brick, etc.) as long as the proper clearances are adhered to and the
fireplace openings are not obstructed in any way. Refer to Clearances,
page 5, and Figure 30).

Use only heat resistant, noncombustible mortar or adhesive when
securing facing material to the front of the fireplace. When placing
facing at the upper edge of the effective opening of the fireplace, provide
an “L” shaped piece of metal, extending the full width of the opening.

Secure with sheet metal screws at a distance high enough from the
edge as to not interfere with the operation of doors. This assures that
the facing material, in time, should not block the opening if it where
to lose cohesion.

Figure 30 - Fireplace Facing (your fireplace may vary from
illustration)

FINISHING YOUR CHIMNEY SYSTEM

Chase Installation

Installing Fireplace Facing

VENTING INSTALLTION

Continued

18" MIN.

 TYP

.

30" MIN.

30" MIN.

Noncombustible
Facing Material

Noncombustible
Facing Material

Do Not
Block
Effective
Opening

“L” Shaped
Metal Support

Summary of Contents for THE SAVANNAH V3610ST

Page 1: ...is or any other appliance WARNING Improper installation adjust ment alteration service or maintenance cancauseinjuryorpropertydamage orloss of life Refer to this manual for correct instal lation and o...

Page 2: ...Dia 38 7cm O D 10 Dia I D 25 4cm 24 60 9cm 6 15 2cm 52 3 4 134cm 17 40 6cm 10 1 4 26cm 11 1 4 28 5cm 7 177mm Outside Air Left Side View Front View Top View Gas Line Conduit 17 3 16 43 6cm 12 30 4cm 1...

Page 3: ...rea providing ventilation and adequate combustion air IMPORTANT Read this owner s manual carefully and completelybeforetryingtoassemble operate orservice this fireplace Improper use of this fireplace...

Page 4: ...all Figure 2 Plan View of Common Location CLEARANCES MINIMUM CLEARANCES TO COMBUSTIBLES Back 1 Min Adjacent Wall 12 Min Chimney Outer Pipe Surfaces 2 Min Bottom Of Fireplaces To Floor 0 Min CAUTION Do...

Page 5: ...dtofityourrequiredplatformheight see Figure 8 The ember protector should be made of 28 gauge minimum galvanized sheet metal to prevent corrosion Figure 4 Mantel Clearances Figure 5 Mantel Clearances F...

Page 6: ...e manufacturer or supplier or the noncombustible material Theminimumrequiredthicknessforanymaterialcouldbeobtained by the following formula K factor x 1 0 inch Thickness required 0 84 If the hearth ex...

Page 7: ...vide rigidity for threaded end 4 Repack insulation around gas line and into sleeves openings Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace ce...

Page 8: ...essary to add screws to keep vertical or angled chimney runs together Figure 16 Pipe Connection WARNING Theopeningaroundthestartercollaron topofthefireplacemustneverbeobstructed Neveruse blown insulat...

Page 9: ...pace ELBOW OFFSET INSTALLATION Chimney weight above offset rests on return elbow Straps must be secured with nails to rafters or joists see Figure 19 Figure 19 Elbow Offset Figure 20 Chimney Supports...

Page 10: ...run with 1 elbow set and 25 feet minimum for a run with 2 elbow sets A set consists of one starter elbow and one return elbow Uncommon circumstances such as neighboring hills tall trees or strong win...

Page 11: ...ed for the pitch of your particular roof Figure 25 Roof Opening FINISHING YOUR CHIMNEY SYSTEM Maximum Chimney Height Cont Chimney Maintenance MINIMUM HEIGHT 15 FT 4 5m MAXIMUM HEIGHT CHASE TERMINATION...

Page 12: ...many shingles as needed to cover exposed area and flashing base Secure in position by nailing through shingles DO NOT NAIL THROUGH FLASHING CONE Figure 26 Flashing Installation Storm Collar Installati...

Page 13: ...proper clearances are adhered to and the fireplaceopeningsarenotobstructedinanyway RefertoClearances page 5 and Figure 30 Use only heat resistant noncombustible mortar or adhesive when securing facing...

Page 14: ...ir and maintain safe temperatures in the firebox If operating with glass doors closed do so at this time Do not operate with doors par tially open Doors must be fully open or fully closed The glass mu...

Page 15: ...load the grate or obstruct the required air space beneath it Always keep ashes from building up under the grate WARNING RISK OF FIRE Replace grate with DESA model 3610ST GR grate only Never obstruct t...

Page 16: ...tedwiththisfireplacemayconstituteafirehazardandwillvoidtheDESAwarranty Storm Collar Storm Collar Comes With Wire Spacer Starter Elbow Return Elbow Vent Hood Vent Plaster Collar HEARTH EXTENSION KIT HE...

Page 17: ...ompleted College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 00...

Page 18: ...55253C 18 For more information visit www desatech com For more information visit www desatech com 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Page 19: ..._________________________________________________________ _______________________________________________________________________________________________ ______________________________________________...

Page 20: ...55253C 20 For more information visit www desatech com For more information visit www desatech com 55253 Rev C 03 03 NOT A UPC 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 55253...

Reviews: