OUTSIDE AIR MECHANISM

The outside air handle is located at the right hand side of the fireplace
rear refractory (see Figure 33). Pull to close, push to open. Always
open the mechanism when starting a fire. This provides adequate
outside combustion air. Close the mechanism when not in use to
prevent cold air from entering the room. Periodically check you’re
outside air intake vent hood for any possible obstructions such as
snow, bushes, etc.

DAMPER MECHANISM

The damper control lever is located inside the fire chamber (see
Figure 33). Make sure lever is cool before handling. Pull down to
CLOSE, push up to OPEN. The damper must be open when lighting
a fire. Not doing so will cause smoke spillage into the room. When
the fireplace is not in use, close the damper to prevent down drafts
to enter the room.

Figure 33 - Damper Operation

GRATE

The grate is designed to provide you with the maximum solid fuel
capacity. Do not attempt to defeat its purpose. Doing so may cause
smoke spillage and a fire hazard. Do not overload the grate or
obstruct the required air space beneath it. Always keep ashes from
building up under the grate.

 WARNING: RISK OF FIRE! Replace grate with

DESA model 3610ST-GR grate only.

Never obstruct the flow of combustion and ventilation air. Keep the
front of the fireplace clear of all obstacles and materials.

For further operating guidelines, instructions, and warranty infor-
mation not contained in this owner’s manual, contact your autho-
rized dealer.

 WARNING: Children and adults should be alerted

to the hazards of high surface temperatures, and to
stay away to avoid burns or clothing ignition. Young
children should be carefully supervised when they
are in the same room as the fireplace.

OPERATING GUIDELINE AND MAINTENANCE INSTRUCTIONS

Damper Mechanism

Outside Air Mechanism

Grate

TECHNICAL SERVICE

OPERATING GUIDELINES
AND MAINTENANCE
INSTRUCTIONS

Continued

GRATE

OUTSIDE AIR
HANDLE
PULL TO CLOSE
PUSH TO OPEN

DAMPER CONTROL LEVER
PULL DOWN TO CLOSE
PUSH UP TO OPEN

TECHNICAL SERVICE

You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA’s Technical Service Depart-
ment at 1-866-672-6040. When calling please have your model and
serial numbers of your heater ready.

You can also visit DESA’s technical services web site at

www.desatech.com.

Summary of Contents for THE SAVANNAH V3610ST

Page 1: ...is or any other appliance WARNING Improper installation adjust ment alteration service or maintenance cancauseinjuryorpropertydamage orloss of life Refer to this manual for correct instal lation and o...

Page 2: ...Dia 38 7cm O D 10 Dia I D 25 4cm 24 60 9cm 6 15 2cm 52 3 4 134cm 17 40 6cm 10 1 4 26cm 11 1 4 28 5cm 7 177mm Outside Air Left Side View Front View Top View Gas Line Conduit 17 3 16 43 6cm 12 30 4cm 1...

Page 3: ...rea providing ventilation and adequate combustion air IMPORTANT Read this owner s manual carefully and completelybeforetryingtoassemble operate orservice this fireplace Improper use of this fireplace...

Page 4: ...all Figure 2 Plan View of Common Location CLEARANCES MINIMUM CLEARANCES TO COMBUSTIBLES Back 1 Min Adjacent Wall 12 Min Chimney Outer Pipe Surfaces 2 Min Bottom Of Fireplaces To Floor 0 Min CAUTION Do...

Page 5: ...dtofityourrequiredplatformheight see Figure 8 The ember protector should be made of 28 gauge minimum galvanized sheet metal to prevent corrosion Figure 4 Mantel Clearances Figure 5 Mantel Clearances F...

Page 6: ...e manufacturer or supplier or the noncombustible material Theminimumrequiredthicknessforanymaterialcouldbeobtained by the following formula K factor x 1 0 inch Thickness required 0 84 If the hearth ex...

Page 7: ...vide rigidity for threaded end 4 Repack insulation around gas line and into sleeves openings Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace ce...

Page 8: ...essary to add screws to keep vertical or angled chimney runs together Figure 16 Pipe Connection WARNING Theopeningaroundthestartercollaron topofthefireplacemustneverbeobstructed Neveruse blown insulat...

Page 9: ...pace ELBOW OFFSET INSTALLATION Chimney weight above offset rests on return elbow Straps must be secured with nails to rafters or joists see Figure 19 Figure 19 Elbow Offset Figure 20 Chimney Supports...

Page 10: ...run with 1 elbow set and 25 feet minimum for a run with 2 elbow sets A set consists of one starter elbow and one return elbow Uncommon circumstances such as neighboring hills tall trees or strong win...

Page 11: ...ed for the pitch of your particular roof Figure 25 Roof Opening FINISHING YOUR CHIMNEY SYSTEM Maximum Chimney Height Cont Chimney Maintenance MINIMUM HEIGHT 15 FT 4 5m MAXIMUM HEIGHT CHASE TERMINATION...

Page 12: ...many shingles as needed to cover exposed area and flashing base Secure in position by nailing through shingles DO NOT NAIL THROUGH FLASHING CONE Figure 26 Flashing Installation Storm Collar Installati...

Page 13: ...proper clearances are adhered to and the fireplaceopeningsarenotobstructedinanyway RefertoClearances page 5 and Figure 30 Use only heat resistant noncombustible mortar or adhesive when securing facing...

Page 14: ...ir and maintain safe temperatures in the firebox If operating with glass doors closed do so at this time Do not operate with doors par tially open Doors must be fully open or fully closed The glass mu...

Page 15: ...load the grate or obstruct the required air space beneath it Always keep ashes from building up under the grate WARNING RISK OF FIRE Replace grate with DESA model 3610ST GR grate only Never obstruct t...

Page 16: ...tedwiththisfireplacemayconstituteafirehazardandwillvoidtheDESAwarranty Storm Collar Storm Collar Comes With Wire Spacer Starter Elbow Return Elbow Vent Hood Vent Plaster Collar HEARTH EXTENSION KIT HE...

Page 17: ...ompleted College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 00...

Page 18: ...55253C 18 For more information visit www desatech com For more information visit www desatech com 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Page 19: ..._________________________________________________________ _______________________________________________________________________________________________ ______________________________________________...

Page 20: ...55253C 20 For more information visit www desatech com For more information visit www desatech com 55253 Rev C 03 03 NOT A UPC 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 55253...

Reviews: