background image

www.desatech.com

113084-01A

10

INSTALLATION

Continued

10. Install door catch bolt (M8 x 1.25-55mm with

two M8 hex nuts) into threaded hole on stove
body (see Figure 7). Use an adjustable wrench
or a 12mm socket. The catch bolt has two hex
nuts attached to it (see Figure 11). The top nut
is a bolt stop and the bottom nut is for door
leveling adjustment.

11. Check general catch bolt alignment with door

claw. Make final adjustment and door level-
ing after stove is in normal standing position.

12. Carefully lift stove back up on its four attached

legs.

13. Remove gas log heater from carton. 

Note: 

Do

not pick up gas log heater by the burner itself.
This could damage heater. Always handle the
gas log heater by the heater base only.

14. Fasten stove pan to stove with two (2) M6

x 1 - 25mm bolts. Use a flat washer and lock
washer with each bolt. Tighten bolts into
threaded holes on stove body (see Figures
7 and 9). Use an adjustable wrench or a
10mm socket.

15. Set top grates into stove top.

Figure 7 - Locating Threaded Holes for

Stove Bottom, Legs, and Door

Attachment (Appearance May Vary

Depending on Model)

Leg
Hole

Leg Hole

Leg Hole

Leg Hole

Door Hinge
Step Bolt Hole

Door Catch Bolt
With Adjustable
Hex Nuts Hole

Holes for
Stove
Bottom

Front

Bottom Of
Stove Unit

Figure 8 - Attaching Stove Legs

(Oxford™ Model Shown)

Bottom Of
Stove Unit

Leg

Bolt

Washers

Figure 9 - Attaching Stove Pan

(Oxford™ Model Shown)

Threaded Holes
in Stove Body

Bolt

Washers

Stove Pan

Figure 10 - Attaching Stove Door

(Appearance May Vary Depending on Model)

Stove
Bottom

Step
Bolt

Door
Hinge

Threaded
Hole

Stove
Door

Bolt Shoulder

Figure 11 - Catch Bolt and Door Claw

Orientation

Adjusting
Nut

Bolt Stop

Catch
Bolt

Door
Claw

Door

Summary of Contents for SVYD18NRA Series

Page 1: ...not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instruction...

Page 2: ...ust be provided Refer to Air for Combustion and Ventilation section on page 5 of this manual This appliance may be installed in an aftermarket permanently located manufactured mobile home where not pr...

Page 3: ...and proper operation of this heater WARNING Any change to this heater or its controls can be dangerous WARNING Do not allow fans to blow directly into the heater Avoidanydraftsthatalterburner flame p...

Page 4: ...r has an Oxy gen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Air for Com bustion and Ventilation pages 5 through 7 If heater keep...

Page 5: ...ction unless provisions are provided foradequatecombustionandven tilation air Read the following in structions to insure proper fresh air for this and other fuel burning appliances in your home Today...

Page 6: ...hem AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a co...

Page 7: ...on the wall connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Section 5 3...

Page 8: ...rs add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventilation...

Page 9: ...tove body on back to attach bottom components to stove body see Fig ure 5 Rest stove on drop cloth or blanket to avoid scratching stove edges 6 Remove remaining pallet wood attached to bot tom of stov...

Page 10: ...an to stove with two 2 M6 x 1 25mm bolts Use a flat washer and lock washer with each bolt Tighten bolts into threaded holes on stove body see Figures 7 and 9 Use an adjustable wrench or a 10mm socket...

Page 11: ...d washers 6 Place freestanding stove in desired position in room Be sure to maintain clearances to combustibles as outlined on page 8 CAUTION After installation and periodically thereafter check to en...

Page 12: ...ironorsteelpipe Internally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to heater If pipe is too small undue...

Page 13: ...t Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve control valve and equipment shutoff valve from gas supply piping system Pressures in excess of 1 2 ps...

Page 14: ...ilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because so...

Page 15: ...30 seconds release control knob If control knob does not pop out when re leased contact a qualified service person or gas supplier for repairs Note If pilot goes out repeat steps 4 through 8 9 Slightl...

Page 16: ...old the control button again until burner turns off see Figure 23 TO LOCK press both buttons on hand held re mote control until light stops flashing Hand held remote control is now locked If the fire...

Page 17: ...nd held remote in the MANU or AUTO mode to prevent inadvertent opera tion i e children operating the hand held re mote control etc The keypad is locked in ei ther on or off Press the POWER and LOCK bu...

Page 18: ...n You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could damagethepilotassembly...

Page 19: ...ressure B Dirty or partially clogged ODS pilot 5 Thermocouple connection loose at control valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if...

Page 20: ...y 2 Clean burner see Cleaning and Maintenance page 18 or replace burner orifice 1 Clean burner see Cleaning and Maintenance page 18 or replace burner orifice 2 Replace damaged burner 3 Replace gas con...

Page 21: ...paint paint remover cigarette smoke cements and glues new carpet or textiles etc create fumes These fumes may mix with combustion air and create odors These odors will disappear over time POSSIBLE CA...

Page 22: ...ech com 113084 01A 22 ILLUSTRATED PARTS BREAKDOWN MODELS SVYD18PRA AND SVYD18NRA O F F P I L O T O N H I L O H I L O O F F P I L O T O N 17 17 18 19 24 15 14 16 13 12 12 11 22 23 20 10 9 21 4 8 5 3 2...

Page 23: ...1 02 103781 01 Gas Control Valve 1 11 103345 02 103345 02 Lower Bracket 1 12 M11084 38 M11084 38 Screw 8 x 38 7 13 104383 02CK 104383 02CK Painted Base Assy 1 14 098271 10 098271 10 Ignitor Cable 1 15...

Page 24: ...A 24 2 5 5 5 5 8 7 4 6 7 1 7 2 4 9 7 3 3 1R 1C 1L 10 9 10 ILLUSTRATED PARTS BREAKDOWN Oxford VCIS Series and PVCIS Series Victor Hearth VH A Series Indicates Color Suffix Designation Oxford Stove Body...

Page 25: ...Nuts 1 Per Unit 1 7 3 Bottom Floor Bolts M6 x 1 25mm Long With Flat Washer And Lock Washer 4 Per Unit 1 7 4 Leg Bolts M8 x 1 25 20mm Long With Flat Washer And Lock Washer 4 Per Unit 1 8 104178 01 Bac...

Page 26: ...bers of your heater how heater was malfunctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory PARTS NOT UNDER WARRANTY Contact au...

Page 27: ...cted on the wall thermostat and the log heater will automatically cycle from pilot to the heat setting selected WALL MOUNT ON OFF SWITCH GWMS2 Not Shown For remote ready models Allows the gas log heat...

Page 28: ...a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a d...

Reviews: