3
103252
• Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use
gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.
• Fueling
a) Personnel involved with fueling shall be qualified and thoroughly familiar
with the manufacturer's instructions and applicable regulations regarding the
safe fueling of heating units.
b) Only the type of fuel specified on the heater's data plate shall be used.
c) All flame, including the pilot light, if any, shall be extinguished and the heater
allowed to cool, prior to fueling.
d) During fueling, all fuel lines and fuel-line connections shall be inspected for
leaks. Any leaks shall be repaired prior to returning the heater to service.
e) At no time shall more than one day's supply of heater fuel be stored inside a
building in the vicinity of the heater. Bulk fuel storage shall be outside the
structure.
f) All fuel storage shall be located a minimum of 25 feet (7.62 m) from heaters,
torches, welding equipment, and similar sources of ignition (exception: the
fuel reservoir integral with the heater unit).
g) Whenever possible, fuel storage shall be confined to areas where floor pen-
etrations do not permit fuel to drip onto or be ignited by a fire at lower eleva-
tion.
h) Fuel storage shall be in accordance with the authority having jurisdiction.
• Never use heater where gasoline, paint thinner, or other highly flammable
vapors are present.
• Follow all local ordinances and codes when using heater.
• Heaters used in the vicinity of tarpaulins, canvas, or similar enclosure materi-
als shall be located a safe distance from such materials. The recommended
minimum safe distance is 10 feet (3.048 m). It is further recommended that
these enclosure materials be of a fire retardant nature. These enclosure mate-
rials shall be securely fastened to prevent them from igniting or from upset-
ting the heater due to wind action.
• Use only in well-vented areas. Provide at least a 4 1/2-square-foot (4,180 square
cm) opening of fresh outside air.
• Use only in places free of flammable vapors or high dust content.
• Use only with the electrical voltage and frequency specified on model plate.
• Use only a three-prong, grounded extension cord.
• Minimum heater clearances from combustibles:
Outlet: 8 Ft. (244 cm)
Sides, Top, and Rear: 4 Ft. (122 cm)
• Locate heater on a stable and level surface while hot or running or a fire may
occur.
• When moving or storing heater, keep heater in a level position or fuel spillage
may occur.
• Keep children and animals away from heater.
• Unplug heater when not in use.
• When used with thermostat, heater may start anytime.
• Never use heater in living or sleeping areas.
• Never block air inlet (rear) or air outlet (front) of heater.
• Never move, handle, refuel, or service a hot, operating, or plugged-in heater.
• Never attach duct work to front or rear of heater.
SAFETY
INFORMATION
Continued
WARNINGS
(Continued)