3
103909
OWNER’S MANUAL
Air For Combustion
Fuel
PRODUCT
IDENTIFICATION
Generic LP 155
LP-PFA/PV 008B
Hot Air
Outlet
(Front)
Handle
Fan Guard
Upper Shell
On/Off Switch
Power Cord
Hose /Regulator
Assembly
Inlet
Connector
Figure 1 - Model RCLP155B
Lower Shell
UNPACKING
1.
Remove all packing items applied to
heater for shipment. Keep plastic cover
caps (attached to inlet connector and
hose/regulator assembly) for storage.
2.
Remove all items from carton.
3.
Check all items for shipping damage.
If heater is damaged, promptly inform
dealer where you bought heater.
Combustion Chamber
Nozzle
Figure 2 - Cross Section Operational View
Clean
Heated
Air Out
(Front)
Cool
Air In
(Back)
THEORY OF
OPERATION
The Fuel System
The hose/regulator assembly attaches to the
propane gas supply. The propane gas moves
through the solenoid valve and out the nozzle.
The Air System
The motor turns the fan. The fan pushes air
into and around the combustion chamber.
This air is heated and provides a stream of
clean, hot air.
The Ignition System
The direct spark ignitor (DSI) sends voltage
to the spark plug/ignitor. The spark plug/
ignitor ignites the fuel and air mixture.
THE SAFETY CONTROL
SYSTEM
This system causes the heater to shut down
if the flame goes out.
Fan
Motor
Power
Cord
Hose/Regulator
Assembly
Solenoid
Valve
On/Off Switch
Air For Combustion
And Heating
Fuel
DSI