THEORY OF OPERATION

The Fuel System:

 The hose/regulator assembly attaches to the propane gas supply. The propane gas 

moves through the solenoid valve and out the nozzle.

The Air System:

 The motor turns the fan. The fan pushes air into and around the combustion chamber. 

This air is heated and provides a stream of clean, hot air.

The Ignition System:

 The direct spark ignitor (DSI) sends voltage to the spark plug/ignitor. The spark 

plug/ignitor ignites the fuel and air mixture.

The Safety Control System:

 This system causes the heater to shut down if the flame goes out.

VENTILATION

 WARNING: Follow the mini-

mum fresh, outside air ventila-

tion  requirements.  If  proper 

fresh, outside air ventilation is 

not provided, carbon monoxide 

poisoning  can  occur.  Provide 

proper fresh, outside air ventila-

tion before running heater.

Provide a fresh air opening of at least 3 ft

2

 (0.28 m

2

for each 100,000 Btu/Hr rating. Provide extra fresh 

air if more heaters are being used.

INSTALLATION

 WARNING: Review and un-

derstand  the  warnings  in  the 

Safety Information

 section, page 

2. They are needed to safely op-

erate this heater. Follow all local 

codes when using this heater.

 WARNING: Test all gas piping 

and connections for leaks after 

installation or servicing. Never 

use an open flame to check for 

a leak. Apply a mixture of liquid 

soap  and  water  to  all  joints. 

Bubbles  forming  show  a  leak. 

Correct all leaks at once.

1.  Provide propane supply system (see 

Propane 

Supply

, page 3).

2.  Connect  POL  fitting  on  hose/regulator  as-

sembly to propane tank(s). Turn POL fitting 

counterclockwise into threads on tank. Tighten 

firmly using wrench. Tighten regulator with vent 

pointing over the hose (see Figure 3, page 5).

3.  Connect hose to inlet connector. Tighten firmly 

using a wrench (see Figure 4, page 5).

 

IMPORTANT:

 Extra hose or piping may be 

used if needed. Install extra hose or piping 

between hose/regulator assembly and propane 

tank. You must use the regulator supplied with 

heater.

Air For Combustion 

And Heating

Fuel

Combustion Chamber

Ignitor

Figure 2 - Cross Section Operational View

Clean 
Heated 
Air Out 
(Front)

Cool 
Air In 
(Back)

Fan

Motor

Power Cord

Hose/
Regulator 
Assembly

Solenoid 
Valve

On/Off Switch

DSI

Nozzle

Summary of Contents for RCLP155AT

Page 1: ...or service this heater Ifyouneedassistanceorheaterinformationsuchasanin structions manual labels etc contact the manufacturer Save this manual for future reference For more information visit www desatech com CANADIAN PROPANE CONSTRUCTION FORCED AIR HEATER OWNER S MANUAL MODEL RCLP155AT 150 000 BTU HR WITH BUILT IN THERMOSTAT TABLE OF CONTENTS Safety Information 2 Unpacking 3 Product Identification ...

Page 2: ... added to propane gas The odor helps you detect a propane gas leak However the odor added to propane gas may fade Propane gas may be present even though no odor exists Make certain you read and understand all warn ings Keep this manual for reference It is your guide to safe and proper operation of this heater 1 Install and use heater with care Follow all local ordinances and codes In the absence o...

Page 3: ...e UNPACKING 1 Remove all packing items applied to heater for shipment Keep plastic cover caps attached to inlet connector and hose regulator assembly for storage 2 Remove all items from carton 3 Check all items for shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT IDENTIFICATION PROPANE SUPPLY Propane gas and propane tank s are to be fur nished by the user...

Page 4: ...ON WARNING Review and un derstand the warnings in the SafetyInformationsection page 2 They are needed to safely op erate this heater Follow all local codes when using this heater WARNING Testallgaspiping and connections for leaks after installation or servicing Never use an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming show a leak Correct all ...

Page 5: ...valve and open again slowly 6 Turn on off switch to the ON position Adjust thermostat to desired setting If heater does not start thermostat setting may be too low Turn thermostat knob to higher position to start heater Note If heater does not start turn on off switch to the OFF position Wait ten seconds for safety control to reset then try again Note If heater still does not start after turning t...

Page 6: ...egulator assembly before each use If hose is highly worn or cut replace 4 Have heater inspected yearly by a qualified service agency 5 Keep inside of heater free from combustible and foreign objects 6 Clean fan blades each season or as needed see Fan PREVENTATIVE MAINTENANCE SCHEDULE Item How Often How To Fan See Fan SERVICE PROCEDURES WARNING Never service heater while it is plugged in connected t...

Page 7: ...Industries at 1 905 826 8010 When calling DESA Industries have ready your name your address model number of your heater how heater was malfunctioning purchase date In most cases we will ask you to return the part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they canʼt supply original replacement part s call DESA Industriesʼ Parts Department at 1 905 826 801...

Page 8: ...tor page 7 If you see spark at ignitor have heater serviced by qualified service person If no spark seen A Loose or disconnected ignitor wire B Wrong spark gap C Bad ignitor electrode 1 Propane supply may be inad equate 2 High surrounding air tem perature causing thermal limit device to shut down heater 3 Restricted air flow 4 Damaged fan 5 Excessive dust or debris in surrounding area OBSERVED FAULT...

Page 9: ...k Motor Power Cord 120 VAC On Off Switch Black High Temp Switch Black Thermostat White Green Green T Black Black Line Neutral Green or Green Yellow Black White Green Black White Motor Blue Blue Blue Green Black White Orange Ignitor Solenoid Valve Automatic Ignition System G V VR ACR AC Position of Leads May Vary WIRING DIAGRAM Electrical Connection Diagram Electrical Ladder Diagram ...

Page 10: ... 10 ILLUSTRATED PARTS BREAKDOWN MODEL RCLP155AT 33 2 1 31 12 26 43 32 10 11 38 20 21 6 7 6 5 3 37 34 Note Screws are standard hardware items 28 7 15 17 27 8 14 36 29 39 4 8 13 25 23 16 42 30 20 35 22 24 18 19 41 44 45 9 40 46 47 ...

Page 11: ...rmostat Knob 1 31 M51104 01 Handle 1 32 M11084 29 Screw 10 16 x 3 4 2 33 097964 03AA Fan Guard 1 34 101206 01 Motor Relay Support Bracket Assembly 1 35 M11143 1 Strain Relief Bushing 1 36 098219 17 Power Cord 1 37 M50631 Rubber Bumper 2 38 NTC 4C Lock Nut 2 39 099157 01 Break Mandrell Rivet 3 16 1 40 099125 01 Terminal Board 1 41 M12461 25 Screw 10 32 x 1 4 2 42 M10908 1 Screw Hex TPG F 6 32 x 25 ...

Page 12: ...EU OF ANY OTHER WARRANTY EITHER EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITYAND FITNESS FORAPARTICULAR PURPOSE DESA Industries assumes no responsibility for indirect incidental or consequential damages Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations or exclusions may not apply to you This Limited Warranty gives you specific ...

Page 13: ...liser ou réparer cet appareil de chauffage Si vous avez besoin d assistance ou de renseignements concernant l appareil de chauffage tels que le mode d em ploi les étiquettes etc communiquez avec le fabricant Conservez ce manuel pour consultation future Pour plus de détails visitez le site www desatech com APPAREIL DE CHAUFFAGE À AIR FORCÉ DE CHANTIER AU GAZ PROPANE POUR LE CANADA MANUEL D UTILISAT...

Page 14: ...auffagenefonctionnepasbien Respirez toutdesuitedel airfrais Vérifiezsilaventilationest suffisante et faites réviser l appareil de chauffage Gazpropane legazpropaneestsansodeur Unproduit odorantestajoutéaugazpropane Cetteodeurvousper metdedétecterunefuitedegaz Cependant cetteodeur ajoutéeaupropanepeutsedissiper Dugazpropanepeut être présent même s il n y a pas d odeur Lisez et comprenez tous les aver...

Page 15: ...ubstituts ou de pièces génériques L utilisation de pièces de rechange inadéquates peut causer des blessures graves ou la mort 31 Cet appareil de chauffage est équipé d un ther mostat Il peut donc s allumer à tout moment DÉBALLAGE 1 Enlevez tout matériau d emballage appliqué sur l appareil de chauffage pour son expédition Conservez les bouchons en plastique sur le raccord d entrée et l assemblage d...

Page 16: ...spourfaire fonctionnercetappareildechauffage sans danger Respectez tous les codes locaux lors de l utilisation de cet appareil de chauffage AVERTISSEMENT testez toutes les conduites de gaz et les connexions pour détecter les fuites après l installation ou la révision N utilisezjamaisdeflammenuepour rechercher une fuite Appliquez une solutiondesavonliquideetd eausur touslesjoints Laprésencedebulles ...

Page 17: ...es des dimensions de la rallonge électrique Jusqu à 15 m 50 pi employez un cordon de calibre 18 AWG Entre 16 et 30 m 51 et 100 pi employez un cordon de calibre 16 AWG Entre 31 et 60 m 101 et 200 pi employez un cordon de calibre 14 AWG 4 Branchez la rallonge électrique dans une prise de terre trifilaire de 120 volts et 60 hertz 5 Ouvrez lentement la vanne d approvisionnement en propane du ou des rés...

Page 18: ...4 Faites inspecter l appareil de chauffage une fois l an par une entreprise de service qualifiée 5 Enlevezlesproduitscombustiblesetlescorpsétran gers qui se trouvent dans l appareil de chauffage 6 Nettoyez les pales de ventilateur chaque saison ou au besoin voir Ventilateur CALENDRIER D ENTRETIEN PRÉVENTIF Pièce Périodicité Comment Ventilateur Voir Ventilateur PROCÉDURES D ENTRETIEN AVERTISSEMENT n...

Page 19: ...s au 1 905 826 8010 Lorsque vous appelez DESA Industries soyez prêt à fournir votre nom votre adresse le numéro du modèle de l appareil de chauffage une description de la panne de l appareil de chauffage la date de l achat En général nous vous demanderons de retourner la pièce à l usine PIÈCES QUI NE SONT PAS SOUS GARANTIE Communiquez avec un revendeur autorisé de ce produit S il ne peut vous four...

Page 20: ...ent 2 Aucune étincelle à l allumeur Voir Allumeur page7 Sivouspercevez une étincelle sur l allumeur faites réparer l appareil de chauffage par un technicien qualifié Si vous ne percevez aucune étincelle A Le fil d allumage est desserré ou débranché B L espace ne permet pas d étin celles C L électrode d allumage est défectueuse 1 L approvisionnement en propane peut ne pas être adéquat 2 La températur...

Page 21: ... On Off Switch Interrupteur de marche arrêt High Temp Switch Interrupteur pour haute température Thermostat White Blanc White Blanc White Blanc T Line Ligne Neutral Neutre Green or Green Yellow Vert ou vert jaune Green Vert Motor Moteur Blue Bleu Blue Bleu Blue Bleu Green Vert Black Noir Black Noir Black Noir White Blanc White Blanc White Blanc Orange Ignitor Allumeur Solenoid Valve Électrovanne A...

Page 22: ...LÉE DES PIÈCES MODÈLES RCLP155AT 33 2 1 31 12 26 43 32 10 11 38 20 21 6 7 6 5 3 37 34 Note Screws are standard hardware items 28 7 15 17 27 8 14 36 29 39 4 8 13 25 23 16 42 30 20 35 22 24 18 19 41 44 45 9 40 46 47 Remarque Les vis sont de type ...

Page 23: ...e de protection du ventilateur 1 34 101206 01 Prêt à monter du support du moteur et du relais 1 35 M11143 1 Bride de cordon 1 36 098219 17 Cordon électrique 1 37 M50631 Butoir en caoutchouc 2 38 NTC 4C Contre écrou 2 39 099157 01 Rivet de mandrin 3 16 po 1 40 099125 01 Bornier 1 41 M12461 25 Vis n 10 32 x 1 4 po 2 42 M10908 1 Vis hexagonale TPG F 6 32 x 0 25 2 43 M11271 8 Écrou à pince 8 44 101480...

Page 24: ...ES DE COMMERCIALITÉ ET D ADÉQUATION À UN BESOIN PARTICULIER DESA Industries n assume aucune responsabilité pour des dommages indirects imprévus ou incidents Certains États ou provinces ne permettent pas l exclusion ou la restriction des dommages imprévus ou incidents et certaines restrictions ou exclusions pourraient ne pas s appliquer à votre cas Cette garantie limitée vous donne des droits spéci...

Reviews: