background image

7

106746

OWNER’S MANUAL

ENGINE OIL

We ship the generator without oil in the
engine crankcase. You must add oil before
starting engine. See engine Owner’s Manual
for specific oil type.

CHECKING OIL LEVEL AND
ADDING OIL

Follow steps below to check oil level. Make
sure engine is level and stopped.

1.

Remove dipstick (see Figure 6). Wipe
dipstick clean.

2.

Insert dipstick into oil filler neck. Do
not screw it in. Oil level should be at
top of filler neck. Oil should cover most
of dipstick. For Model PGH11000IE
only, the oil should be between the two
dots on dipstick.

3.

If level is low, fill to top of oil filler neck
(see Figure 6). For Model PGH11000IE
only, fill to top dot on dipstick. Only use
oil recommended in engine Owner’s
Manual.

Note:

 If oil level is too low, oil alert system

will shutdown engine and prevent engine
from restarting.

Figure 6 - Checking Oil Level (Model
PGH7500IE Shown)

FUEL

Oil Level
At Top Of
Filler Neck

Dipstick

Oil

Use clean, fresh, unleaded gasoline. Use
gasoline with octane rating of 86 or higher.
Service station gasoline pumps should dis-
play the octane rating. Using gasoline with
lower octane level could damage engine.
Avoid getting dirt, dust, or water in fuel
tank. Do not mix oil with gasoline.

See engine Owner’s Manual for more
information.

 WARNING: Gasoline presents

a hazard of fire or explosion.
Gasoline is flammable. Its vapor
is explosive.
• Keep fuel out of children’s

reach.

• Refuel generator in a well-

vented area. Do not fill fuel tank
in the dark. Do not refuel while
engine is running. Unhook all
electrical loads and shut off
engine before refueling.

• Do not overfill fuel tank. Al-

ways allow room for fuel to
expand. If you overfill tank, fuel
can overflow onto hot engine.
This can cause fire or explo-
sion. After refueling, tightly
close fuel tank cap.

• Do not spill fuel. Fuel or fuel

vapor may ignite. If fuel spills,
make sure area is dry before
starting engine.

• Never smoke in refueling area.

Never allow open flames or
sparks in area.

• Store fuel in approved con-

tainer. Store fuel in a well-
vented area free of open flames
or sparks.

IMPORTANT:

 Make sure battery connec-

tions are the correct polarity. Electric start
generators use negative ground, 12-volt DC
starting system.

A battery is not supplied with generator.
You must provide a 12-volt, 32-amp-hour
battery. The positive and negative battery
cables are supplied with generator. You
must install these cables before mounting
battery.

BATTERY

 WARNING: Battery gives off

explosive gases. Keep sparks,
flames, and cigarettes away. Do
not remove or install battery
cables when engine is cranking
or running. Only service or use
battery in a well-vented area.

 WARNING: Battery contains

sulfuric acid. Contact with skin
or eyes may cause severe burns.
Do not tilt generator with battery
installed. Tilting could cause bat-
tery acid to spill. Wear protective
clothing and face shield when
servicing. Keep out of children’s
reach.
• If battery acid gets on your

skin, wash with water.

• If battery acid gets in your eyes,

flush with water at least 15 min-
utes. Call a doctor at once.
Battery acid is poisonous.

• If swallowed, drink large

amounts of water or milk. Fol-
low with milk of magnesia or
vegetable oil. Call a doctor at
once.

 CAUTION: If you remove bat-

tery, insulate the red, positive (+)
battery cable terminal. Insulate
with electrical tape. Exposed ter-
minal may spark when generator
runs.

Continued

Summary of Contents for PGH1100IE

Page 1: ...r use of generator can cause serious injury Keep this manual for future reference Generator Models PGH7500IE and PGH11000IE RES ET TES T 120 VOL TS F U E L F RES ET 120 240 VOL TS 120 240V FUL L POW E...

Page 2: ...nfluence of alcohol and those at high altitudes Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this generator Safetyi...

Page 3: ...rops if it is sparking if it produces smoke or flames if it vibrates at high levels if it has a damaged receptacle 12 Keep generator and nearby areas clean Keep generator free of oil mud and other for...

Page 4: ...arts Check for shipping damage If any parts are missing or damaged promptly inform dealer where you bought generator 4 Battery cables are supplied These cables are in a separate bag inside generator c...

Page 5: ...120 240 V Twist Lock 30 Amp 30 Amp 120 240 V 50 A No Yes General Honda Engine H P 13 20 Honda Model GX390K1VXE GX620VXA3 Fuel Type Gasoline Gasoline Fuel Tank Capacity 5 gal 5 gal Oil Alert System Yes...

Page 6: ...he oil alert system to shut down engine See engine Owner s Manual for more information Figure 2 Engine Switch Location HONDA OFF ON START ENGINE SW CIRCUIT BREAKER ELECTRIC START A battery is not supp...

Page 7: ...efueling Do not overfill fuel tank Al ways allow room for fuel to expand Ifyouoverfilltank fuel can overflow onto hot engine This can cause fire or explo sion After refueling tightly close fuel tank c...

Page 8: ...Locate the red positive battery cable from starter solenoid Connect it to the positive battery terminal see Figures 11 and 12 3 Locate the black negative battery cable attached to engine block Connect...

Page 9: ...starting This will help guard against deadly electric shock Only use grounded plugs with generator Onlyusegroundedex tension cords Only use three wire or double insulated power tools WARNING For a gr...

Page 10: ...00 x Chart 2 Always use starting watts not running watts when figuring correct electrical load x Motors of higher horsepower are not generally used Chart 1 Typical Electric Appliance Wattages DETERMIN...

Page 11: ...damage generator Use only grounded ex tension cords Power only grounded or double insulated items Do not overload receptacles Both generators have the fol lowing receptacles see Figure 14 120V 15 amp...

Page 12: ...ure 17 Choke Button Closed Model PGH11000IE Only Choke Button Pulled Out Closed Position 4 Start the engine A Recoil Starter Turn engine switch to the ON position see Figure 18 Remove slack from start...

Page 13: ...ine Let engine reach full speed 3 Connect electrical loads one at a time If the load consists of electric motors start them first Always start the larg est first Start each motor individually DISCONNE...

Page 14: ...upply the engine Owner s Manualwithgenerator Refertothatmanual for questions concerning engine mainte nance and repairs Non enginepartsrequirelittlemaintenance Keep generator clean Use a damp cloth to...

Page 15: ...d Yellow Yellow White White Auto Idle Control Board Yellow White White White Circuit Breaker 30A Circuit Breaker 30A Circuit Breaker 45A Circuit Breaker 45A Green T2 Green Black Red White Main Winding...

Page 16: ...3 Stator 1 14 27003002 Fan Bracket 1 15 27003015S Screw M8 x 20 4 16 099891 01 Rotor Nut Flanged 8mm 1 17 099892 01 Foam Pad 1 18 099842 04 Draw Bolt 1 19 27003003 Bearing 1 20 27003012S Diode 2 21 Ro...

Page 17: ...ting Bolts 4 10 099891 01 Nuts 4 11 103189 01 Top Box 1 12 099701 01 Screw and Washer 6 13 103198 01 Plastic Cap 1 14 103199 01 Bearing 1 15 103200 01 Borelly Washer 1 16 27003012S Diode 2 17 103201 0...

Page 18: ...ENERATORS 9 10 11 12 13 11 16 13 13 17 17 18 11 11 11 16 11 16 21 20 19 14 23 14 23 23 16 16 16 16 10 11 16 11 16 22 F U E L F 1 3 2 4 24 7 8 6 6 27 7 25 15 5 26 ILLUSTRATED PARTS LIST FOR MODEL PGH75...

Page 19: ...4 2 18 099756 01 Engine Spreader 1 19 099750 01 Hook Bolt 5 16 18 2 20 099749 01 Battery Mounting Bracket 1 21 NEC 5C Lock Nut 5 16 18 2 22 100410 01 Sems Screw 8 18 x 1 2 4 23 M10908 74 Screw 1 4 20...

Page 20: ...ORS 9 10 12 15 33 11 17 13 24 24 18 11 24 5 11 20 11 19 16 14 23 36 35 34 21 25 24 13 27 22 F U E L F 1 3 2 4 26 6 37 7 11 32 25 24 34 11 25 24 8 29 30 31 28 24 11 24 ILLUSTRATED PARTS LIST FOR MODEL...

Page 21: ...0908 74 1 4 20 x 1 2 Screw 1 24 WP 5C 5 16 Washer 24 25 26007004 5 16 18 x 3 4 Bolt 10 26 WP 4C 1 4 Washer 4 27 WLI 8 1 2 Lock Washer 2 28 H8C5 20C 5 16 18 x 2 50 Screw 4 29 105035 01 Handle 2 30 1030...

Page 22: ...1 11 100410 01 Sems Screw 8 18 x 1 2 4 12 100149 01 Control Box 1 13 22261000 U Nut 8 103348 04 Control Panel Assembly 1 103348 08 Control Panel Assembly Auto Idle Models 1 100177 07 Panel Schematic...

Page 23: ...100366 01 Rocker Switch 1 16 15324000 120V 15A Duplex Receptacle 1 102927 01 Control Panel Assembly 1 100177 05 Panel Schematic Diagram 1 103257 01 Auto Idle PC Board Kit 1 103258 02 Solenoid Assembl...

Page 24: ...orized dealers of this product If they cannot supply original replacement part s either contact your nearest Parts Central or call DESA International s Parts Department at 1 800 972 7879 for referral...

Page 25: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 26: ...bility of the owner DESA International makes no warranty with respect to the engine and engine components not of its manufacture They are subject to warranties of their manufacturers To the full exten...

Reviews: