background image

kEEp THIS WARRANTY

WARRANTY INFORMATION

701 Industrial Drive
P.O. Box 90004

Bowling Green, KY 42102-9004

www.desatech.com

Always specify model and serial numbers when communicating with the factory.

The only warranty applicable is our standard written warranty. We make no other warranty, expressed or 

implied.

119171-01
Rev. E
11/06

LIMITED WARRANTIES FOR NEW AND FACTORY 

RECONDITIONED pRODUCTS

New Products:

 DESA Heating, LLC warrants this heater and any parts thereof, to be free of defects 

in materials and workmanship for two (2) years from the date of first purchase, when operated and 

maintained in accordance with the manufacturer's instructions. These warranties are extended only to 

the original retail purchaser, when proof of purchase is provided.

Factory Reconditioned Heaters:

 DESA Heating, LLC warrants this factory reconditioned heater and 

any parts thereof, to be free of defects in materials and workmanship for thirty (30) days from the date of 
first purchase, when operated and maintained in accordance with the manufacturer's instructions. These 
warranties are extended only to the original retail purchaser, when proof of purchase is provided.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) 
required to restore this heater to proper operating condition and an allowance for labor when provided by 

a DESA Heating, LLC Authorized Service Center. Warranty part(s) MUST be obtained through authorized 
dealers of this product and/or DESA Heating, LLC who will provide original factory replacement parts. 

Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a 

qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear 

or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or 
defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all 

such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE 
OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED 

WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO () 

YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA HEATING, 

LLC’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA 

HEATING, LLC SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING 
INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation 

of incidental or consequential damages, so the above limitation on implied warranties or exclusion or 

limitation on damages may not apply to you.

This warranty gives you specific legal rights and you may also have other rights that vary from state to state.

For information about this warranty write:

NOT A UPC

Patent Pending 

Model

Serial No.

Date Purchased

119171 01

Summary of Contents for NZ108

Page 1: ...the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourga...

Page 2: ...tured mobile home where not prohib ited by local codes Aftermarket Completion of sale not for purpose of resale from the manufacturer WARNING This product contains and or generates chemicals known to...

Page 3: ...etoavoidburnsorclothing ignition Heater will remain hot for a time after shutdown Allow surface to cool before touching Carefully supervise young chil dren when they are in the same room with heater M...

Page 4: ...andards Institute Inc 1430 Broadway New York NY 10018 National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 State of Massachusetts The installation must be made by a licensed plum...

Page 5: ...air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of un usually tight construction you must provide additional fresh air Unusual...

Page 6: ...upport ________ Btu Hr actual amount AIR FOR COMBUSTION AND VENTILATION Continued Example 51 200 Btu Hr maximum the space can support 60 000 Btu Hr actual amount of Btu Hr used The space in the above...

Page 7: ...for use as supplemental heat Use this heater along with your primary heating system Do not install this heater as your pri mary heat source If you have a centralheatingsystem youmay run system s circ...

Page 8: ...nimum To Top Surface Of Carpeting Tile Or Other Combustible Material Left Side Right Side 10 25 4 cm INSTALLATION ITEMS Before installing heater make sure you have the items listed below for propane L...

Page 9: ...d al lows you to attach mounting bracket to hollow walls wall areas between studs or to solid walls concrete or masonry Decide which method better suits your needs Either method will provide a secure...

Page 10: ...Wall Stud Method For attaching mounting bracket to wall studs 1 Drill holes at marked locations using 9 64 drill bit 2 Place mounting bracket onto wall Line up last hole on each end of bracket with h...

Page 11: ...nal Regulator With Vent Pointing Down External Regulator Propane LP Supply Tank Vent Pointing Down Figure 13 Installing Base Feet Sheet Metal Screw Wood Screw Base Foot Mounting Base Feet to Floor 1 R...

Page 12: ...n must include equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 15 IMPORTANT Install an equipmen...

Page 13: ...her opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air Figure 18 Checking Gas Joints for Propane LP...

Page 14: ...by hand When lighting the pi lot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air...

Page 15: ...contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure 8 Keep control knob pressed in for...

Page 16: ...ttern Operating Heater Continued THERMOSTAT CONTROL OPERATION The thermostatic control used on these models differs from standard thermostats Standard thermostats simply turn on and off the burner The...

Page 17: ...CABINET Air Passageways Use pressurized air to clean Exterior Use a soft cloth dampened with a mild soap and water mixture Wipe the cabinet to re move dust Figure 27 Pilot Air Inlet Pilot Assembly Pi...

Page 18: ...tor setting is not correct 1 Not enough combustion ventilation air REMEDY 1 Replace pilot assembly 2 Replace pilot assembly 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tu...

Page 19: ...il snug then tighten 1 4 turn more 5 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 17 or replace ODS pilot assembly 6 Replace pilot assembly 7 R...

Page 20: ...te and correct all leaks see Checking Gas Con nections page 12 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking Gas Con nections pa...

Page 21: ...e Heater Weight 22 lb 10 kg Average Shipping Weight 25 5 lb 11 6 kg Note Dimensions listed are outer most points on the heater includes control knobs and grill For purposes of input adjustment Wiring...

Page 22: ...www desatech com 119171 01E 22 Illustrated Parts Breakdown Cabinet body Models NZ108 and NZ109 8 5 6 7 4 3 1 2 16 10 9 11 12 13 17 14 18 20 15 29 21 22 16 23 See page 24...

Page 23: ...Control Knob 1 12 099415 18 Gas Regulator Propane LP Gas 1 099415 19 Gas Regulator Natural Gas 1 13 104819 02 Regulator Bracket 1 14 119099 01 Lower Baffle 1 15 099038 01 Strain Relief Bushing 1 16 1...

Page 24: ...hermocouple Kit 1 3 099387 11 Pilot Tubing 1 4 104818 03 Outlet Tubing Valve to Burner 1 5 099218 08 Burner 1 6 099056 24 Injector Plaque A or C 1 2 099056 25 Injector Plaque A or C 1 2 7 099056 01 In...

Page 25: ...page 27 or call DESA Heat ing Products at 1 866 672 6040 for referral information When calling DESA Heating Products have ready model number of your heater the replacement part number Service Hints Wh...

Page 26: ...866 672 6040 for referral in formation You can also write to the address listed on the back page of this manual equipment SHUTOFF VALVE GA5010 For all models Equipment shutoff valve with 1 8 NPT tap...

Page 27: ...Street Bowling Green KY 42103 3414 270 846 1199 1 800 654 8534 Fax 1 800 846 0090 franktalk aol com Master Parts Dist 1251 Mound Ave NW Grand Rapids MI 49504 2672 616 791 0505 1 800 446 1446 www nbmc...

Page 28: ...will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accordance with all loca...

Reviews: