background image

www.desatech.com

118620-01E

10

Figure 11 - Installing Bottom Mounting 

Screws

Side View

Front View

Wall

Spacer

Heater

INSTALLATION

Continued

Attaching Mounting Bracket To Wall

Note:

  Wall  anchors,  mounting  screws  and 

spacers are in hardware package. The hard

-

ware package is provided with heater.

Attaching To Wall Stud Method

For attaching mounting bracket to wall studs
1.  Drill holes at marked locations using 9/64" 

drill bit.

2.  Place  mounting  bracket  onto  wall.  Line 

up last hole on each end of bracket with 
holes drilled in wall.

3.  Insert mounting screws through bracket 

and into wall studs.

4.  Tighten screws until mounting bracket is 

firmly fastened to wall studs.

Attaching To Wall Anchor Method

For  attaching  mounting  bracket  to  hollow 
walls (wall areas between studs) or solid walls 
(concrete or masonry)
1.  Drill  holes  at  marked  locations  using 

5/16" drill bit. For solid walls (concrete or 
masonry), drill at least 1" deep.

2.  Fold wall anchor as shown in Figure 8.
3.  Insert wall anchor (wings first) into hole. 

Tap anchor flush to wall.

4.  For  thin  walls  (1/2"  or  less),  insert  red 

key  into  wall  anchor.  Push  red  key  to 
“pop” open anchor wings (see Figure 9). 

IMPORTANT:

  Do  not  hammer  key!  For 

thick walls (over 1/2" thick) or solid walls, 
do not pop open wings.

5.  Place mounting bracket onto wall. Line up 

last hole on each end of bracket with wall 
anchors.

6.  Insert mounting screws through bracket 

and into wall anchors.

7.  Tighten screws until mounting bracket is 

firmly fastened to wall.

Figure 8 - Folding 

Anchor

Figure 10 - Mounting Heater Onto 

Mounting Bracket

Stand-
Out Tab

Figure 9 - Popping 

Open Anchor Wings 

For Thin Walls

Mounting Bracket 
(attached to wall)

Horizontal Slots

Placing Heater On Mounting Bracket

1.  Locate two horizontal slots on back panel 

of heater.

2.  Place heater onto mounting bracket. Slide 

horizontal  slots  onto  stand-out  tabs  on 
mounting bracket.

Installing Bottom Mounting Screws

1.  Locate two bottom mounting holes. These 

holes are near bottom on back panel of 
heater (see Figure 11).

2.  Mark screw locations on wall.
3.  Remove heater from mounting bracket.
4.  If installing bottom mounting screws into 

hollow or solid wall, install wall anchors. 
Follow steps 1 through 4 under 

Attaching 

To Wall Anchor Method

.

 

If  installing  bottom  mounting  screw  into 
wall stud, drill holes at marked locations 
using 9/64" drill bit.

Bottom 

Mounting 
Holes

Summary of Contents for NY100

Page 1: ...WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the g...

Page 2: ...irth defects or other reproductive harm IMPORTANT Read this owner s manual carefully and completely beforetryingtoassemble operate or service this heater Improper use of this heater can cause seri ous...

Page 3: ...plate This appliance is not convertible for use with other gases 2 Do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors 3 This heater shall not be insta...

Page 4: ...each purchaser a copy of 527 CMR 30 upon sale of the unit Vent free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts Unpacking 1 Remove heater fr...

Page 5: ...air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of un usually tight construction you must provide additional fresh air Unusuall...

Page 6: ...l Gas Code ANSIZ223 1 NFPA54Section5 3 or applicable local codes DETERMINING FRESH AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine...

Page 7: ...mary heat source If you have a centralheatingsystem youmay run system s circulating blower whileusingheater Thiswillhelp circulatetheheatthroughoutthe house In the event of a power outage you can use...

Page 8: ...ects arelessthan36 fromthefront top or sides of the heater as a fireplace insert in high traffic areas in windy or drafty areas Figure 4 Mounting Clearances As Viewed From Front of Heater INSTALLATION...

Page 9: ...areas between studs or to solid walls concrete or masonry Decide which method better suits your needs Either method will provide a secure hold for the mounting bracket Marking Screw Locations 1 Tape m...

Page 10: ...red key into wall anchor Push red key to pop open anchor wings see Figure 9 IMPORTANT Do not hammer key For thick walls over 1 2 thick or solid walls do not pop open wings 5 Place mounting bracket on...

Page 11: ...n Sheet Metal Screw Wood Screw Base Foot Mounting Base Feet to Floor 1 Remove front panel see Removing Front Panel of Heater page 9 2 Position heater with base feet in desired location Mark holes for...

Page 12: ...r CAUTION For propane LP gas never connect heater di rectly to the propane LP supply This heater requires an external regulator not supplied Install theexternalregulatorbetweenthe heater and propane L...

Page 13: ...pplyanoncorrosiveleakdetec tion fluid to all joints Bubbles forming show a leak Correct all leaks at once CAUTION For propane LP gas make sure external regula tor has been installed between propane LP...

Page 14: ...Correct all leaks at once Pressure Testing Heater Gas Connections 1 Open equipment shutoff valve see Figure 18 2 For natural gas open main gas valve located on or near gas meter For pro pane LP gas o...

Page 15: ...TING INSTRUCTIONS 1 STOP Read the safety information column 1 2 Make sure equipment shutoff valve is fully open 3 Turn off any electric power to the appli ance if service is to be performed 4 Turn pil...

Page 16: ...ter 30 seconds release control knob Now follow step 9 under Lighting Instructions page 15 5 Replace front panel UP DOWN SET TIME PROGRAM OFF SET PM ROOM Figure 24 Remote Control LCD Display Mode Butto...

Page 17: ...button again and minute digits will begin flashing 4 Press UP or DOWN button until desired minutes are displayed 5 Press and release SET button on remote control to stop time digits from flashing and...

Page 18: ...l or thermo mode If current time is not within program on time unit will stay off until pre programmed turn on time is reached Pre programmed time P 1 and P 2 icons will continue to display on screen...

Page 19: ...on slide switch for selecting the mode of operation REMOTE OFF With slide switch in REMOTE position system will only operate if remote receiver receives commands from remote control With slide switch...

Page 20: ...witch Code Switches Receiver Back of Remote Control Operating Blower This heater has a thermostatic blower that will automatically turn ON or OFF Note Your heater and thermostat blower will not turn o...

Page 21: ...yearly by a qualified service person We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no great...

Page 22: ...position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP gas only 6 ODS pilot is clogged 7 Gas regulator setting is not correct OBSERVED PROBLEM Whenignitorbuttonispressed there...

Page 23: ...ane LP gas company 1 Contact local natural or propane LP gas company 2 Clean burner see Cleaning and Maintenance page 21 or replace burner orifice 1 Clean burner see Cleaning and Maintenance page 21 o...

Page 24: ...ies not in stalled Battery power is low 3 Code settings on receiver and remote control do not match 4 Receiver and remote con trol too far apart REMEDY 1 Check burner for dirt and debris If found clea...

Page 25: ...artially clogged 1 Gas leak See Warning statement above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement above 1 Not enough combustion venti...

Page 26: ...nder warranty Parts Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s call DESA Heating Products Technical Ser vice Department at 1 866 672 604...

Page 27: ...se Kit GA4550 For all models For locating heater on the floor away from a wall Complete installation and operating instructions included Electronic ignitor Kit GA435 Not Shown For all models Provides...

Page 28: ...118620 01E 28 OFF PILOT ON 20 4 21 24 17 18 19 2 3 5 6 8 16 9 10 11 12 13 14 22 7 1 15 26 25 23 28 27 9 29 Illustrated Parts Breakdown Models nY100 nY101 nY102 nY103 nY104 nY105 nY106 nY107 nY114 nY11...

Page 29: ...5 06 Injector 1 103845 07 Injector 1 103845 08 Injector 1 15 099066 02 Mounting Bracket 1 16 099415 17 Gas Regulator 1 099415 18 Gas Regulator 1 17 NJF 8C Hex Nut 1 18 118627 01 Burner Tube 1 19 11862...

Page 30: ...1 0505 1 800 446 1446 www nbmc com Parts Centrals These Parts Centrals are privately owned businesses They have agreed to support our customer s needs by providing original replacement parts and acces...

Page 31: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 32: ...roducts who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accordance wi...