  WARNING:  This  product 

contains  and/or  generates 

chemicals  known  to  the  state 

of California to cause cancer or 

birth defects or other reproduc

-

tive harm.

IMPORTANT: Read this owner’s 

manual carefully and completely 

before  trying  to  assemble,  op

-

erate  or  service  this  fireplace. 

Improper  use  of  this  fireplace 

can  cause  serious  injury  or 

death  from  burns,  fire,  explo

-

sion, electrical shock and carbon 

monoxide poisoning.

 DANGER: Carbon monoxide 

poisoning may lead to death!

Carbon  Monoxide  Poisoning: 

Early  signs 

of carbon monoxide poisoning resemble the 

flu, with headaches, dizziness or nausea. If 
you have these signs, the fireplace may not 
be working properly. 

Get fresh air at once!

 

Have  fireplace  serviced.  Some  people  are 

more affected by carbon monoxide than oth-

ers. These include pregnant women, people 
with heart or lung disease or anemia, those 
under the influence of alcohol and those at 

high altitudes.

Natural and Propane/LP Gas:

 Natural and 

Propane/LP  gases  are  odorless. An  odor-
making agent is added to these gases. The 

odor helps you detect a gas leak. However, 

the odor added to the gas can fade. Gas may 
be present even though no odor exists.
Make  certain  you  read  and  understand  all 

warnings. Keep this manual for reference. It 

is your guide to safe and proper operation of 

this fireplace.

  WARNING:  Any  change  to 

this  heater  or  its  controls  can 

be dangerous.

SAFETy

Continued

  WARNING:  Do  not  use  a 

blower  insert,  heat  exchanger 

insert or other accessory not ap

-

proved for use with this heater. 

 WARNING: Do not allow fans 

to blow directly into the fireplace. 

Avoid any drafts that alter burner 

flame patterns. Ceiling fans can 

create  drafts  that  alter  burner 

flame  patterns.  Altered  burner 

patterns can cause sooting.

Due  to  high  temperatures,  the 

appliance should be located out 

of traffic and away from furniture 

and draperies.

Do not place clothing or other 

flammable  material  on  or  near 

the appliance. Never place any 

objects on the heater.

Heater  base  assembly  becomes 

very hot when running heater. Keep 

children and adults away from hot 

surface to avoid burns or clothing 

ignition. Heater will remain hot for a 

time after shutdown. Allow surface 

to cool before touching.

Carefully supervise young chil

-

dren when they are in the room 

with heater.

You  must  operate  this  heater 

with  the  fireplace  screen  and 

hood  in  place.  Make  sure  fire

-

place  screen  and  hood  are  in 

place before running heater.

Keep  the  appliance  area  clear 

and free from combustible ma

-

terials, gasoline and other flam

-

mable vapors and liquids.

Summary of Contents for EZ18N

Page 1: ...l switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department...

Page 2: ...ING This is an unvented gas fired heat er It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion...

Page 3: ...though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this fireplace WARNING Any change to this heater...

Page 4: ...p inside fireplace will cause glass to burst Make sure there are no obstructions across openings of fireplace 8 To prevent the creation of soot follow the instructions in Cleaning page 20 9 Before usi...

Page 5: ...must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy...

Page 6: ...rectly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the un confined space Adjoining rooms are communicating only if there are...

Page 7: ...unt of Btu Hr used ________ Btu Hr maximum the space can support ________ Btu Hr actual amount used Example 51 200 Btu Hr maximum the space can support 73 000 Btu Hr actual amount of Btu Hr used The s...

Page 8: ...ted Crawl Space To Crawl Space To Attic Installation Figure 2 Ventilation Air from Inside Building Or Remove Door into Adjoining Room Option 3 Ventilation Grills Into Adjoining Room Option 2 Ventilati...

Page 9: ...pe of gas natural or propane LP If your gas supply is not the correct gas type do not install heater Call dealer where you bought heater for proper type heater WARNING This appliance is for either nat...

Page 10: ...e material is more than 12 you may need the hood accessory to deflect heat away from your mantel shelf See Figure 5 and Figures 6 and 7 page 11 for minimum clearances IMPORTANT If you cannot meet thes...

Page 11: ...lled at Floor Level Figure 7 Minimum Mantel Clearances When Using Hood Floor Clearances A If installing appliance on the floor level you must maintain the minimum distance of 14 to combustibles see Fi...

Page 12: ...inimum permanent flue opening you must provide Attach damper clamp so the minimum permanent flue open ing will be maintained at all times Area of Various Standard Round Flues Diameter Area 5 20 sq inc...

Page 13: ...e to Fireplace Floor Masonry Screw CONNECTING TO GAS SUPPLY WARNING This appliance requires a 1 2 NPT National Pipe Thread inlet connection to the pressure regulator WARNING A qualified service person...

Page 14: ...nt lightly to male NPT threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves Propane LP Supply Tank External Regulator with Vent Po...

Page 15: ...r near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping sys tem Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all...

Page 16: ...ailure to use only parts specifically approved with this heater may result in property damage or personal injury It is very important to install these logs exactly as instructed Do not modify logs Onl...

Page 17: ...uctions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SME...

Page 18: ...ou don t smell gas go to the next step Operation Continued Figure 23 Pilot Ignitor Electrode Thermocouple Pilot Burner Figure 22 Control Knob and Ignitor Button Location OFF PILOT ON Control Knob Elec...

Page 19: ...kwise to the PILOT position 3 Press in control knob and turn clockwise to the OFF position 4 Close equipment shutoff valve see Figure 15 page 15 Manual lighting procedure 1 Follow steps 1 through 5 un...

Page 20: ...rculating air passageways of heater clean Inspect these areas of heater before each use Have heater inspected yearly by a qualified service person Heater may need more frequent cleaning due to excessi...

Page 21: ...slotted burner flame holes should be open with yellow flame pres ent All round burner flame holes should be open with a small blue flame present Some burner flame holes may become blocked by debris or...

Page 22: ...hile in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free i...

Page 23: ...te for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning page 20 or re...

Page 24: ...checked by local natural or propane LP gas company 3 Observe minimum installa tion clearances see pages 9 through 11 4 Clean burners see Clean ing page 20 or replace burner orifice s 1 Turn heater off...

Page 25: ...s from paint hair spray glues cleaners chemicals new carpet etc See IMPOR TANT statement above 2 Low fuel supply propane LP only 3 Gas leak See Warning statement at top of page 1 Gas leak See Warning...

Page 26: ...www desatech com 119678 01C 26 Parts Models EZ18N EZ18P EZ24N and EZ24P LPG 11 13 31 10 30 4 1 8 3 12 8 2 5 6 7 28 22 23 8 20 17 24 26 19 21 15 2 23 29 9 18 16 25 8 8...

Page 27: ...ural 1 12 101004 04 Front Burner Injector Natural 1 101004 01 Front Burner Injector Propane LP 1 101004 22 Front Burner Injector Natural 1 101004 06 Front Burner Injector Propane LP 1 13 107634 01 NG...

Page 28: ...2 3 5 6 7 KEY NO PART NO DESCRIPTION QTY 1 114984 01 Middle Log 1 114984 12 Middle Log 1 2 114984 02 Left Top Log 1 114984 13 Left Top Log 1 3 114984 03 Right Top Log 1 114984 14 Right Top Log 1 4 114...

Page 29: ...acement part s call DESA Heating LLC at 1 866 672 6040 for referral information A list of authorized dealers can be found by visiting www desatech com When calling DESA Heating LLC have ready model an...

Page 30: ...it gives you the tools and instructions to make it easy to clean all critical areas of your appliance Accessories FIREPLACE HOOD Black GA6050 Brass GA6052 Antique Brass GA6053 For all models Helps def...

Page 31: ..._____________________________ __________________________________________________________ __________________________________________________________ ____________________________________________________...

Page 32: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Reviews: