background image

111826-02C

For more information, visit www.desatech.com

22

ACCESSORIES

For all models. 

DAMPER CLAMP - GA6080

(Not Shown)

For Remote-Ready and Variable Manually-Controlled Models. 
Per ma nent ly  opens  chim ney  fl ue damper for vent ed operation.

LAVA ROCK - GA6060

(Not Shown)

For all models. Order when additional rock is desired. (1.8 lb. 
bag)

ACCESSORIES

Purchase these appliance accessories from your local dealer. If they 
can not supply these accessories, call DESA International at 1-866-
672-6040 for referral information. You can also write to the ad dress 
listed on the back page of this manual.

EQUIPMENT SHUTOFF VALVE - GA5010

For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 
1/2" NPT pipe. 

FIREPLACE HOOD

Black - GA6050
Brass - GA6052
Antique Brass - GA6053

For all models. Helps defl ect heat away from mantel or wall above 
fi replace. Fits openings 28" to 48" wide.

RECEIVER AND HAND-HELD REMOTE 
CONTROL KIT - GHRC 

For all Remote-Ready Mod els. Al lows the gas log appliance to be 
turned on and off by using a hand-held remote control. 

CLEANING KIT - GCK

(Not Shown)

For all models. Your vented gas appliance requires reg u lar cleaning 
and main te nance to prevent performance problems. This kit gives 
you the tools and instructions to make it easy to clean all critical 
areas of your appliance. 

INFORMATION VIDEO - 108917-01

For all models. A care and maintenance video is available by call-
ing 1-866-672-6040.

Summary of Contents for Design Dynamics VTD-18N-BTB

Page 1: ...appliance may be installed in an aftermarket manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This applian...

Page 2: ...18 ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST 20 ACCESSORIES 22 OWNER S REGISTRATION FORM 23 WARRANTY INFORMATION Back Cover your building immediately call your gas supplier from a neighbor s phone Fo...

Page 3: ...urface to avoid burns or clothing ignition Log set will remain hot for a time after shutdown Allow surface to cool before touching 14 Carefully supervise young children when they are in the room with...

Page 4: ...nformation on pages 4 through 6 will help you classify your space and provide adequate ventilation Unusually Tight Construction The air that leaks around doors and windows may provide enough freshairf...

Page 5: ...8 m3 per kw of the aggregate input rating of all appli ances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished wi...

Page 6: ...Into Adjoining Room Option 2 Ventilation Grills Into Adjoining Room Option 1 12 12 AIR FOR COMBUSTION AND VENTILATION Ventilation Air Cont the outdoors or spaces open to the outdoors These spaces inc...

Page 7: ...y in a solid fuel burning fireplace with a working flue and constructed of noncom bustible material The charts in Figure 4 indicate technical information regarding the installation of your gas log set...

Page 8: ...ure regulator dam age could occur Install external regulator with the vent pointing down as shown in Figure 8 page 9 Pointing the vent down protects it from freezing rain or sleet CAUTION Use only new...

Page 9: ...leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once CAUTION Make sure external regulator has been installed between propane LP supply and appliance Seeguidelinesun...

Page 10: ...joints from gas meter to equipment shutoff valve for natural gas or propane LP supply to equipment shutoff valve for propane LP see Figure 11 Apply noncorrosive leak detection fluid to all joints Bubb...

Page 11: ...d turn control knob counterclockwise to the PILOT position Press in control knob for five 5 seconds see Figure 13 Note You may be running this appliance for the first time after hooking up to gas supp...

Page 12: ...NG PROCEDURE 1 Follow steps 1 through 6 under Lighting Instructions 2 Depress control knob and light pilot with match 3 Keep control knob pressed in for 30 seconds after lighting pilot After 30 second...

Page 13: ...orrect Pilot Flame Pattern Your pilot may vary from pilots shown Pilot Burner Thermocouple Pilot Burner Thermocouple Figure 17 Incorrect Pilot Flame Pattern Your pilot may vary from pilots shown Therm...

Page 14: ...gnitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replace ignit...

Page 15: ...Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burners until air is removed from line Have gas line checked by lo cal natura...

Page 16: ...DS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve or gas control defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statemen...

Page 17: ...of water Maximum 10 5 W C 10 5 W C Minimum 5 0 W C 5 0 W C Shipping Weight 32 lbs 34 lbs For purpose of input adjustment VTD 18P PDG VTD 18P BTB VTD 24P PDG VTD 24P BTB Btu Variable 37 000 54 000 41 0...

Page 18: ...arranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call DESA International s Technical...

Page 19: ...111826 02C For more information visit www desatech com 19 19 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 20: ...EAKDOWN VTD 24N PDG VTD 24P PDG VTD 24N BTB VTD 24P BTB VTD 18N PDG VTD 18P PDG VTD 18N BTB VTD 18P BTB 3 Log sets and mounting plates are ordered as an assembly REMOTE MODELS ONLY GTA Replacement Par...

Page 21: ...6 01 111796 02 111816 01 111793 01 see table page 20 112359 01 111800 01 111372 01 112370 01 111371 02 111807 02 111796 01 097159 04 103784 01 103784 02 099998 01 111817 02 111828 01 103778 01 111816...

Page 22: ...HUTOFF VALVE GA5010 For all models Equipment shutoff valve with 1 8 NPT tap Fits 1 2 NPT pipe FIREPLACE HOOD Black GA6050 Brass GA6052 Antique Brass GA6053 For all models Helps deflect heat away from...

Page 23: ...ge Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 000 to 49 999 50...

Page 24: ...111826 02C For more information visit www desatech com 24 2701 S Harbor Blvd Santa Ana CA 92704 www desatech com Postage Required TM...

Page 25: ..._________________________________ ________________________________________________________________________________________________ _____________________________________________________________________...

Page 26: ...cement parts voids this warranty The appliance MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to pa...