background image

2

107100

VENT-FREE PROPANE/LP HEATER

For more information, visit www.desatech.com

LOCAL CODES

Install and use heater with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code, ANS Z223.1,
 also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY  10018

National Fire Protection Association, Inc.

Batterymarch Park

1.

This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.

2.

Do not place propane/LP supply tank(s)
inside any structure. Locate propane/
LP supply tank(s) outdoors.

3.

If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do

not use any phone in your building

• immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions

• if you cannot reach your gas supplier,

call the fire department

 DANGER: Carbon monoxide

poisoning may lead to death!

SAFETY
INFORMATION

Carbon Monoxide Poisoning:

 Early signs

of carbon monoxide poisoning resemble
the flu, with headaches, dizziness, or nau-
sea. If you have these signs, the heater may
not be working properly. Get fresh air at
once!
 Have heater serviced. Some people
are more affected by carbon monoxide
than others. These include pregnant women,
people with heart or lung disease or ane-
mia, those under the influence of alcohol,
and those at high altitudes.

Propane/LP Gas:

 

Propane/LP gas is odor-

less. An odor-making agent is added to pro-
pane/LP gas. The odor helps you detect a
propane/LP gas leak. However, the odor added
to propane/LP gas can fade. Propane/LP gas
may be present even though no odor exists.

Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this heater.

4.

This heater shall not be installed in a
bedroom or bathroom.

5.

This heater needs fresh, outside air ven-
tilation to run properly. This heater has
an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS shuts
down the heater if not enough fresh air
is available. See Air for Combustion
and Ventilation,
 pages 5 through 7.

6.

If heater shuts off, do not relight until
you provide fresh, outside air. If heater
keeps shutting off, have it serviced.

7.

To prevent the creation of soot, follow
the instructions in Cleaning and Main-
tenance, 
page 16.

8.

Before using furniture polish, wax, car-
pet cleaner, or similar products, turn
heater off. If heated, the vapors from
these products may create a white pow-
der residue within burner box or on
adjacent walls or furniture.

9.

Do not run heater
• where flammable liquids or vapors

are used or stored.

• under dusty conditions.

10. Do not use heater if any part has been

under water. Immediately call a quali-
fied service technician to inspect the
room heater and to replace any part of
the control system and any gas control
which has been under water.

11. Turn off and unplug heater and let cool

before servicing. Only a qualified service
person should service and repair heater.

12. Operating heater above elevations of

4,500 feet may cause pilot outage.

13. To prevent performance problems, do

not use propane/LP fuel tank of less
than 100 lbs. capacity.

 WARNINGS

IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, oper-
ate, or service this heater. Im-
proper use of this heater can
cause serious injury or death from
burns, fire, explosion, electrical
shock, and carbon monoxide
poisoning.

 WARNING: Any change to

this heater or its controls can be
dangerous.

 WARNING: Do not use a

blower insert, heat exchanger
insert, or other accessory not
approved for use with this heater.

 WARNING: Do not allow fans

to blow directly into the heater.
Avoid any drafts that alter burner
flame patterns. Ceiling fans can
create drafts that alter burner
flame patterns. Altered burner
patterns can cause sooting.

Do not place clothing or other
flammable material on or near
the appliance. Never place any
objects on the heater.

Carefully supervise young chil-
dren when they are in same room
with heater.

Keep the appliance area clear and
free from combustible materials,
gasoline, and other flammable
vapors and liquids.

Due to high temperatures, the
appliance should be located out
of traffic and away from furniture
and draperies.

Surface of heater becomes very
hot when running heater. Keep
children and adults away from
hot surfaces to avoid burns or
clothing ignition. Fireplace will
remain hot for a time after shut-
down. Allow surfaces to cool be-
fore touching.

Make sure screen is in place be-
fore running heater.

Summary of Contents for Comfort Glow RFP30TA

Page 1: ...stallation and service must be performed by a qualified installer service agency or the gas supplier RFP30TA WARNING Improper installa tion adjustment alteration ser vice or maintenance can cause inju...

Page 2: ...shuts off do not relight until you provide fresh outside air If heater keeps shutting off have it serviced 7 To prevent the creation of soot follow the instructions in Cleaning and Main tenance page 1...

Page 3: ...g o dk irln fg pd fA SD FK IG LF JI als kd idk oe m kg o dk irln fg pd f AS DF KI GL FJ I als kd idk oe m kg o dk irln fg pd fA SD FK IG LF JI als kd idk oe m kg o dk irln fg pd f AS DF KI GL FJ I als...

Page 4: ...te brass front trim in brass trim package 2 Slide the head of two truss head screws from hardware packet into each end of brass front trim see Figure 4 3 Line up screws with holes in front panel see F...

Page 5: ...communicating only iftherearedoorlesspassagewaysorventila tion grills between them PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code NFPA 54 ANS Z223 1 Sec tion5 3...

Page 6: ...of all fuel burning appliances in the space Vent free heater _____________________ Btu Hr Gas water heater _____________________ Btu Hr Gas furnace _____________________ Btu Hr Vented gas heater ____...

Page 7: ...entilation for required size of ventilation grills or ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one with...

Page 8: ...r walls WARNING Never install the heater in a bedroom or a bathroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 36 inches from the front top or...

Page 9: ...bracket Marking Screw Locations 1 Tape mounting bracket to wall where heater will be located Make sure mounting bracket is level WARNING Maintainminimum clearances shown in Figure 11 If you can provi...

Page 10: ...Mounting Bracket INSTALLATION Continued Attaching Mounting Bracket to Wall Note Wall anchors mounting screws and spacers are in hardware package The hard ware package is provided with heater Attachin...

Page 11: ...card shipping screws 3 Line up mounting holes on top of hearth base with holes in bottom of heater see Figure 16 4 Using a Phillips screwdriver secure hearth base to heater with four sheet metal screw...

Page 12: ...tects it from freezing rain or sleet We recommend that you install a sediment trap in supply line as shown in Figure 19 Locate sediment trap where it is within reach for cleaning Install in piping sys...

Page 13: ...leak 5 Correct all leaks at once 6 Reconnect heater and equipment shutoff valve to gas supply Check re connected fittings for leaks Open Closed Equipment Shutoff Valve Figure 21 Checking Gas Joints Fi...

Page 14: ...Figure 23 Pilot GRH OV 015 Control Knob Ignitor Button PIL OT L O O F F H I IGNITOR LIGHTING INSTRUCTIONS Ignitor Button Control Knob Figure 22 Control Knob In The OFF Position 7 Keep control knob pre...

Page 15: ...ur own comfort levels THERMOSTAT CONTROL OPERATION MANUAL LIGHTING PROCEDURE Figure 24 Correct Pilot Flame Pattern Figure 25 Incorrect Pilot Flame Pattern Check pilot flame pattern and burner flame pa...

Page 16: ...reatesoot We recommendthatyoucleantheuniteverythree months during operation and have heater in spected yearly by a qualified service person Wealsorecommendthatyoukeeptheburner tube and pilot assembly...

Page 17: ...ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 2 Reconnect ignitor cable 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replac...

Page 18: ...nte nance page 16 or replace burner orifice 1 Turn heater off when using furniture polish wax carpet cleaners or similar products OBSERVED PROBLEM Burner does not light after ODS pilot is lit Delayed...

Page 19: ...s off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion Moisture condensationnoticedonwindows REMEDY 1 This is common with most heaters If noise is exce...

Page 20: ...East Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 sales portableheaterparts com techservice portableheaterparts com FBD 1349 Adams Street Bowling Green KY 42103 3414 270 846 1199 1...

Page 21: ...molding Available in light oak finish walnut finish or an unfin ished hardwood ready to stain or paint Complete assembly and installation instruc tions included ACCESSORIES Purchasetheseheateraccesso...

Page 22: ...7100 VENT FREE PROPANE LP HEATER For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN RFP30TA 1 2 9 10 10 12 13 14 15 17 19 20 23 24 25 6 26 6 7 1 1 3 1 28 5 16 18 4 22 1 1 1 21 11...

Page 23: ...Cable 1 11 098249 01 Nut M5 2 12 107486 01 ODS Pilot Assembly 1 13 103447 01 Burner 1 14 099387 03 3 16 Pilot Tubing 1 15 103845 10 Injector 1 16 NJF 8C Nut Hex 1 17 099415 06 Pressure Regulator 1 18...

Page 24: ...by improper installation Travel diagnostic cost labor transportationandanyandallsuchothercostsrelatedtorepairingadefectiveheaterwillbetheresponsibilityoftheowner TO THE FULL EXTENT ALLOWED BY THE LAW...

Reviews: