background image

17

104433

OWNER’S MANUAL

TROUBLESHOOTING

OBSERVED PROBLEM

When ignitor button is pressed, there is no
spark at ODS/pilot

When ignitor button is pressed, there is
spark at ODS/pilot but no ignition

ODS/pilot lights but flame goes out when
control knob is released

 CAUTION : Never use a wire,

needle, or similar object to clean
ODS/pilot. This can damage ODS/
pilot unit.

 WARNING: Turn off and un-

plug heater and let cool before
servicing. Only a qualified ser-
vice person should service and
repair heater.

POSSIBLE CAUSE

1. Ignitor cable pinched or wet

2. Ignitor electrode not connected to igni-

tor cable

3. Piezo ignitor nut is loose

4. Broken ignitor cable
5. Ignitor electrode broken
6. Bad piezo ignitor
7. Ignitor electrode positioned wrong

1. Gas supply turned off or equipment

shutoff valve closed

2. Control knob not in PILOT position
3. Control knob not pressed in while in

PILOT position

4. Air in gas lines when installed

5. ODS/pilot is clogged

6. Gas regulator setting is not correct

1. Control knob not fully pressed in
2. Control knob not pressed in long enough

3. Safety interlock system has been

triggered

4. Equipment shutoff valve not fully open
5. Thermocouple connection loose at con-

trol valve

6. Pilot flame not touching thermocouple,

which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot

7. Thermocouple damaged
8. Control valve damaged

REMEDY

1. Free ignitor cable if pinched by any

metal or tubing. Keep ignitor cable dry

2. Reconnect ignitor cable

3. Tighten nut holding piezo ignitor to base

panel of log set. Nut is located behind
base panel.

4. Replace ignitor cable
5. Replace ignitor
6. Replace piezo ignitor
7. Replace ignitor

1. Turn on gas supply or open equipment

shutoff valve

2. Turn control knob to PILOT position
3. Press in control knob while in PILOT

position

4. Continue holding down control knob.

Repeat igniting operation until air is re-
moved

5. Clean ODS/pilot (see Cleaning and

Maintenance, page 16) or replace ODS/
pilot assembly

6. Replace gas regulator

1. Press in control knob fully
2. After ODS/pilot lights, keep control

knob pressed in 30 seconds

3. Wait one minute for safety interlock sys-

tem to reset. Repeat ignition operation

4. Fully open equipment shutoff valve
5. Hand tighten until snug, then tighten

1/4 turn more

6. A) Contact local natural gas company

B) Clean ODS/pilot (see Cleaning and
Maintenance
, page 16) or replace ODS/
pilot assembly

7. Replace thermocouple
8. Replace control valve

Continued

Note:

 For additional help, visit DESA

International’s technical service web site
at 

www.desatech.com

.

Note:

 All troubleshooting items are listed in

order of operation.

www.desatech.com

Summary of Contents for Comfort Glow RFN30T

Page 1: ...tallation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice or maintenance can cause injury or pro...

Page 2: ...ges 5 through 7 5 If heater shuts off do not relight until you provide fresh outside air If heater keeps shutting off have it serviced 6 To prevent the creation of soot follow the instructions in Clea...

Page 3: ...I GL FJ I als kd idk oe m kg o dk irln fg pd fA SD FK IG LF JI als kd idk oe m kg o dk irln fg pd f AS DF KI GL FJ I als kd idk oe m kg o dk irln fg pd fA SD FK IG LF JI als kd idk oe m kg o dk irln f...

Page 4: ...uts from inside of front panel Tighten with wrench Truss Head Screw Nut Front Panel Figure 5 Attaching Brass Front Trim to Front Panel Brass Front Trim ASSEMBLY ASSEMBLING HEATER Tools Required Philli...

Page 5: ...uction 2 Unconfined Space 3 Confined Space The information on pages 5 through 7 will help you classify your space and provide adequate ventilation Unusually Tight Construction The air that leaks aroun...

Page 6: ...of all fuel burning appliances in the space Vent free heater __________________ Btu Hr Gas water heater __________________ Btu Hr Gas furnace __________________ Btu Hr Vented gas heater _____________...

Page 7: ...d size of ventilation grills or ducts WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both space...

Page 8: ...can locate heater on floor The optional hearth base is needed You can also install the optional decorative mantel on the heater some mantels require hearth base IMPORTANT Only use optional mantel and...

Page 9: ...of heater It has been taped there for shipping Remove mounting bracket from back panel 20 3 4 Min 11 Min 16 Adjoining Wall Only Insert Mounting Screws Through Last Hole On Each End Floor Figure13 Moun...

Page 10: ...are in hardware package The hard ware package is provided with heater Attaching To Wall Stud Method Forattachingmountingbrackettowallstuds 1 Drill holes at marked locations using 9 64 drill bit 2 Plac...

Page 11: ...th base as shown in Figure 19 7 Assemble brass trim see steps 1 through 7 under Assembling and At taching Brass Trim page 5 8 Slide base trim on heater base Attach brass trim to base with two brass sc...

Page 12: ...ING TO GAS SUPPLY WARNING A qualified service personmustconnectheatertogas supply Follow all local codes IMPORTANT Check gas line pressure be fore connecting heater to gas line Gas line pressure must...

Page 13: ...ing show a leak Correct all leaks at once Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 21 2 Pressurize supply piping system by either usingcompress...

Page 14: ...ervice person or gas supplier for repairs Note If pilot goes out repeat steps 3 through 7 This heater has a safety interlock system Wait one 1 minute before lighting pilot again 8 Turn control knob co...

Page 15: ...djusts the amount of gas flow to the burner This increases or de creases the burner flame height At times the room may exceed the set temperature If so the burner will shut off The burner willcyclebac...

Page 16: ...or gas quality is bad If so contact your local natural gas supplier CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the...

Page 17: ...e to cool causing pilot flame to go out This prob lem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 7 Thermocouple damaged 8 Control valve d...

Page 18: ...regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by l...

Page 19: ...for Combustion and Venti lation requirements page 5 POSSIBLE CAUSE 1 Metal expanding while heating or con tracting while cooling 1 Heater burning vapors from paint hair spray glues etc see IMPORTANT s...

Page 20: ...so IN 46383 9704 All States 219 462 7441 1 800 362 6951 sales portableheaterparts com techservice portableheaterparts com FBD 1349 Adams Street Bowling Green KY 42103 3414 270 846 1199 1 800 654 8534...

Page 21: ...the floor Includes brass trim Complete installation instruc tions included PRESTIGE MANTEL WITH BUILT IN BASE Unfinished GMC27U Series Finished GMC26F Series Finished Oak GMC28F For use with heater F...

Page 22: ...22 104433 VENT FREE NATURAL GAS HEATER 15 000 TO 30 000 BTU HR 12 1 12 2 1 2 9 10 11 12 17 18 19 21 22 23 8 20 7 1 3 5 16 4 25 24 1 6 13 14 15 26 10 ILLUSTRATED PARTS BREAKDOWN RFN30T...

Page 23: ...099440 05 ODS Pilot Assembly 1 12 1 098514 01 Thermocouple 1 12 2 098594 01 Ignitor Electrode 1 13 103447 01 Burner 1 14 098517 01 3 16 Pilot Tubing 1 15 103845 07 Injector 1 16 103408 01 Burner Brack...

Page 24: ...artsthatarenotinoriginalconditionbecauseofnormalwearandtear orpartsthatfailorbecome damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel...