background image

16

104433

VENT-FREE NATURAL GAS HEATER

 15,000 TO 30,000 BTU/HR

CLEANING AND
MAINTENANCE

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air

to clean.

Exterior

• Use a soft cloth dampened with a mild

soap and water mixture. Wipe the cabi-
net to remove dust.

 CAUTION: You must keep

control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
pet hair, bedding material, etc.

 WARNING: Turn off heater

and let cool before cleaning.

Note:

 Use only original replacement parts.

This will protect your warranty coverage
for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), either contact your nearest Parts
Central (see page 20) or call DESA
International’s Technical Service Depart-
ment at 1-800-323-5190.

When calling DESA International, have ready:

• your name

• your address

• model and serial numbers of your heater

• how heater was malfunctioning

• type of gas used (propane/LP or natural gas)

• purchase date

Usually, we will ask you to return the defec-
tive part to the factory.

PARTS NOT UNDER
WARRANTY

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), either contact your nearest Parts
Central (see page 20) or call DESA
International’s Parts Department at 1-800-
972-7879 for referral information.

When calling DESA International, have ready:

• model number of your heater

• the replacement part number

REPLACEMENT
PARTS

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burner will have delayed ignition

• heater will not produce specified heat

When Gas Quality Is Bad

• pilot will not stay lit

• burner will produce flames and soot

• heater will backfire when lit

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
natural gas supplier.

CLEANING BURNER
INJECTOR HOLDER AND
PILOT AIR INLET HOLE

The primary air inlet holes allow the proper
amount of air to mix with the gas. This pro-
vides a clean burning flame. Keep these holes
clear of dust, dirt, lint, and pet hair. Clean
these air inlet holes prior to each heating
season. Blocked air holes will create soot. We
recommend that you clean the unit every three
months during operation and have heater in-
spected yearly by a qualified service person.

We also recommend that you keep the burner
tube and pilot assembly clean and free of
dust and dirt. To clean these parts we recom-
mend using compressed air no greater than
30 PSI. Your local computer store, hard-
ware store, or home center may carry com-
pressed air in a can. You can use a vacuum
cleaner in the blow position. If using com-
pressed air in a can, please follow the direc-
tions on the can. If you don't follow direc-
tions on the can,  you could damage the pilot
assembly.

1.

Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.

2.

Inspect burner, pilot, and primary air
inlet holes on injector holder for dust
and dirt (see Figure 29).

3.

Blow air through the ports/slots and
holes in the burner.

Figure 29 - Injector Holder On Outlet
Burner Tube

4.

Check the injector holder located at the
end of the burner tube again. Remove
any large particles of dust, dirt, lint, or
pet hair with a soft cloth or vacuum
cleaner nozzle.

5.

Blow air into the primary air holes on
the injector holder.

6.

In case any large clumps of dust have
now been pushed into the burner repeat
steps 3 and 4.

Clean the pilot assembly also. A yellow tip
on the pilot flame indicates dust and dirt in
the pilot assembly. There is a small pilot air
inlet hole about two inches from where the
pilot flame comes out of the pilot assembly
(see Figure 30). With the unit off, lightly
blow air through the air inlet hole. You may
blow through a drinking straw if compressed
air is not available.

Burner
Tube

Injector Holder

Primary Air Inlet
Holes

Figure 30 - Pilot Inlet Air Hole

Pilot Assembly

Pilot Air Inlet
Hole

Ports/Slots

Summary of Contents for Comfort Glow RFN30T

Page 1: ...tallation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice or maintenance can cause injury or pro...

Page 2: ...ges 5 through 7 5 If heater shuts off do not relight until you provide fresh outside air If heater keeps shutting off have it serviced 6 To prevent the creation of soot follow the instructions in Clea...

Page 3: ...I GL FJ I als kd idk oe m kg o dk irln fg pd fA SD FK IG LF JI als kd idk oe m kg o dk irln fg pd f AS DF KI GL FJ I als kd idk oe m kg o dk irln fg pd fA SD FK IG LF JI als kd idk oe m kg o dk irln f...

Page 4: ...uts from inside of front panel Tighten with wrench Truss Head Screw Nut Front Panel Figure 5 Attaching Brass Front Trim to Front Panel Brass Front Trim ASSEMBLY ASSEMBLING HEATER Tools Required Philli...

Page 5: ...uction 2 Unconfined Space 3 Confined Space The information on pages 5 through 7 will help you classify your space and provide adequate ventilation Unusually Tight Construction The air that leaks aroun...

Page 6: ...of all fuel burning appliances in the space Vent free heater __________________ Btu Hr Gas water heater __________________ Btu Hr Gas furnace __________________ Btu Hr Vented gas heater _____________...

Page 7: ...d size of ventilation grills or ducts WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both space...

Page 8: ...can locate heater on floor The optional hearth base is needed You can also install the optional decorative mantel on the heater some mantels require hearth base IMPORTANT Only use optional mantel and...

Page 9: ...of heater It has been taped there for shipping Remove mounting bracket from back panel 20 3 4 Min 11 Min 16 Adjoining Wall Only Insert Mounting Screws Through Last Hole On Each End Floor Figure13 Moun...

Page 10: ...are in hardware package The hard ware package is provided with heater Attaching To Wall Stud Method Forattachingmountingbrackettowallstuds 1 Drill holes at marked locations using 9 64 drill bit 2 Plac...

Page 11: ...th base as shown in Figure 19 7 Assemble brass trim see steps 1 through 7 under Assembling and At taching Brass Trim page 5 8 Slide base trim on heater base Attach brass trim to base with two brass sc...

Page 12: ...ING TO GAS SUPPLY WARNING A qualified service personmustconnectheatertogas supply Follow all local codes IMPORTANT Check gas line pressure be fore connecting heater to gas line Gas line pressure must...

Page 13: ...ing show a leak Correct all leaks at once Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 21 2 Pressurize supply piping system by either usingcompress...

Page 14: ...ervice person or gas supplier for repairs Note If pilot goes out repeat steps 3 through 7 This heater has a safety interlock system Wait one 1 minute before lighting pilot again 8 Turn control knob co...

Page 15: ...djusts the amount of gas flow to the burner This increases or de creases the burner flame height At times the room may exceed the set temperature If so the burner will shut off The burner willcyclebac...

Page 16: ...or gas quality is bad If so contact your local natural gas supplier CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the...

Page 17: ...e to cool causing pilot flame to go out This prob lem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 7 Thermocouple damaged 8 Control valve d...

Page 18: ...regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by l...

Page 19: ...for Combustion and Venti lation requirements page 5 POSSIBLE CAUSE 1 Metal expanding while heating or con tracting while cooling 1 Heater burning vapors from paint hair spray glues etc see IMPORTANT s...

Page 20: ...so IN 46383 9704 All States 219 462 7441 1 800 362 6951 sales portableheaterparts com techservice portableheaterparts com FBD 1349 Adams Street Bowling Green KY 42103 3414 270 846 1199 1 800 654 8534...

Page 21: ...the floor Includes brass trim Complete installation instruc tions included PRESTIGE MANTEL WITH BUILT IN BASE Unfinished GMC27U Series Finished GMC26F Series Finished Oak GMC28F For use with heater F...

Page 22: ...22 104433 VENT FREE NATURAL GAS HEATER 15 000 TO 30 000 BTU HR 12 1 12 2 1 2 9 10 11 12 17 18 19 21 22 23 8 20 7 1 3 5 16 4 25 24 1 6 13 14 15 26 10 ILLUSTRATED PARTS BREAKDOWN RFN30T...

Page 23: ...099440 05 ODS Pilot Assembly 1 12 1 098514 01 Thermocouple 1 12 2 098594 01 Ignitor Electrode 1 13 103447 01 Burner 1 14 098517 01 3 16 Pilot Tubing 1 15 103845 07 Injector 1 16 103408 01 Burner Brack...

Page 24: ...artsthatarenotinoriginalconditionbecauseofnormalwearandtear orpartsthatfailorbecome damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel...

Reviews: