background image

LIMITED WARRANTY

COMFORT GLOW VENTED GAS LOGS

DESA International warrants this product to be free from defects on burner system for two (2) years and logs for a lifetime from the
date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable
instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this log set
to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST
be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts.
Failure to use original factory replacement parts voids this warranty. The log set MUST be installed by a qualified installer in accordance
with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become
damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost,
labor, transportation and any and all such other costs related to repairing a defective log set will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT;
THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA-
TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON BURNER SYSTEM AND A LIFETIME ON LOGS FROM THE DATE
OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF
THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER
INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential
damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004

www.desatech.com

KEEP THIS WARRANTY

WARRANTY INFORMATION

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written
warranty. We make no other warranty, expressed or implied.

901049-01
Rev. A
08/99

INTERNATIONAL

NOT A UPC

901049 01

Summary of Contents for Comfort Glow CVTR18

Page 1: ...rect installation and operational procedures For assistance or additional information consult a qualified installer service agency or the gas supplier WARNING This appliance is for installation only i...

Page 2: ...d fire box must be cleaned of soot creosote ashes and loose paint by a qualified chimney cleaner Creosote will ignite if highly heated Inspect chimney flue for damage 5 You must operate this log set w...

Page 3: ...that can be purchased sepa rately for this log set You must use the millivolt valve safety pilot kit to use remote accessories with this appliance See Acces sories page 17 UNPACKING CAUTION Do not rem...

Page 4: ...heatlossinhomes Homeowners weather strip and caulk around windows and doorstokeepthecoldairoutandthewarmair in During heating months home owners want their homes as airtight as possible While it is go...

Page 5: ...combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _____________ Btu Hr maximum the space can support...

Page 6: ...he two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and V...

Page 7: ...must be in stalled only in a solid fuel burning fireplace with a working flue and constructed of non combustible material The charts in Figure 4 indicate technical information regarding the installati...

Page 8: ...s Needed Before installing log set make sure you have the items listed below piping check local codes sealant resistant to LP gas manual shutoff valve test gauge connection adjustable crescent wrench...

Page 9: ...16 wrench 6 Slip the air restrictor over the 1 8 pipe nipple Apply thread sealant to the male threads and install the rear burner nozzle onto the fitting Tighten with a 9 16 wrench 7 Place the grate...

Page 10: ...alve Manifold Block Figure 11 Installing Gas Control Valve Control Rod INSTALLATION Continued rod to the front 9 Install valve cover to burner pan using screws provided 10 Install thermocouple pilot a...

Page 11: ...e immedi ately Tighten or reassemble the loose connection s using pipe joint com pound until burner system is leak free 4 When the burner is tested and leak free observe the individual tongues of flam...

Page 12: ...f you then smell gas STOP Fol low the safety information above If you don t smell gas go on to the next step 4 Light a match and lay it on top of the U shaped burner near the edge of the cover on the...

Page 13: ...essed in for five 5 seconds Note You may be running this log set for the first time after hooking up to gas supply If so the control knob may need to be pressed in for 30 sec onds This will allow air...

Page 14: ...king sooting excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon soot where flames contact the logs This is especially true with propane LP gas...

Page 15: ...ce page 17 or replace pilot assembly 5 Hand tighten until snug then tighten 1 4 turn more 6 Replace thermocouple 7 Replace control valve 1 Clean burner orifice 2 Contact local natural or propane LP ga...

Page 16: ...tatement at top of page OBSERVED PROBLEM Log Set produces a clicking ticking noise just after burner is lit or shut off Log Set produces unwanted odors Gas odor even when control knob is in OFF positi...

Page 17: ...onal sTechnicalServiceDe partment at 1 800 DESA LOG 1 800 337 2564 WhencallingDESAInternational haveready your name your address modelandserialnumbersofyourfireplace how fireplace was malfunctioning t...

Page 18: ...18 901049 VENTED NATURAL GAS LOGS ILLUSTRATED PARTS BREAKDOWN CVTR18 CVTR24 4 19 23 21 22 20 24 25 26 2 3 8 7 11 10 1 5 6 15 9 14 12 13 27 16 18 5 17...

Page 19: ...Natural Gas 1 12 901761 01 901761 01 1 8 Hex Nipple 1 13 901760 01 901760 01 Manifold Block 1 14 901751 01 901751 01 Air Restrictor 1 15 901756 01 901756 01 Valve Cover 1 16 901056 01 901056 01 Brass...

Page 20: ...s Parts and Service 2444 North 5th Street Hartsville SC 29550 7704 803 332 0191 Parts Department Cans Unlimited Inc P O Box 645 Taylor SC 29687 0013 All States 803 879 3009 1 800 845 5301 Parts Depar...

Page 21: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 22: ..._______________________ _______________________________________________________________________________________________ ________________________________________________________________________________...

Page 23: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 24: ...log set will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND...