OWNER’S MANUAL

36"

3"

FLOOR

CEILING

Minimum

Minimum T
Of Carpeti
Combustib

8"

Minimum
From
Sides Of
Heater

Right
Side

Left
Side

Figure 4 - Mounting Clearances As Viewed
From Front of Heater

INSTALLATION

Mounting

Screw

Locations

10 

7

/

8

"

Minimum To

Maintain 6"

Clearance
From Wall

3

/

4

"

20 

1

/

4

"

Minimum To

Maintain 3"

Clearance

From Floor

FLOOR

JOINING WALL

2.

Mark two mounting screw locations on
wall (see Figure 5).

Figure 5 - Mounting Screw Locations

For convenience and efficiency, install heater

• where there is easy access for operation,

inspection, and service.

• in coldest part of room.

INSTALLING HEATER TO
WALL

Marking Screw Locations

1.

Determine where you will locate heater.

 CAUTION: If you install the

heater in a home garage
• heater pilot and burner must be

at least 18 inches above floor

• locate heater where moving

vehicle will not hit it

IMPORTANT:

 Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation, 
pages 4 through 6.

 CAUTION: This heater cre-

ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.

 WARNING: Never install the

heater
• in a bathroom
• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the heater

• as a fireplace insert
• in high traffic areas
• in windy or drafty areas

 WARNING: Maintain the mini-

mum clearances shown in Fig-
ure 4. If you can, provide greater
clearances from floor, ceiling,
and joining wall.

LOCATING HEATER

This heater is designed to be mounted on a
wall.

 WARNING: A qualified ser-

vice person must install heater.
Follow all local codes.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not
natural, do not install heater. Call dealer where
you bought heater for proper type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have
the items listed below.

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• ground joint union

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

* A CSA/AGA design-certified equipment
shutoff valve with 1/8" NPT tap is an ac-
ceptable alternative to test gauge connec-
tion. Purchase the optional CSA/AGA de-
sign-certified equipment shutoff valve from
your dealer. See Accessory, page 16.

NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

Minimum To
Top Surface
Of Carpeting,
Tile Or Other
Combustible
Material

 WARNING: Maintain minimum

clearances shown in Figure 5. If
you can, provide greater clear-
ances from floor and joining wall.

Continued

Summary of Contents for Comfort Glow CGN10RLA

Page 1: ...alified installer service agency or the gas supplier WARNING Thisisanunvented gas firedheater Itusesair oxy gen from the room in which it is installed Provisions for ad equate combustion and venti lat...

Page 2: ...ser vicing Only a qualified service person should service and repair heater 12 Operating heater above elevations of 4 500 feet could cause pilot outage WARNING Any change to this heater or its control...

Page 3: ...Protection Association Inc Batterymarch Park Quincy MA 02269 UNPACKING 1 Remove heater from carton 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any shipping da...

Page 4: ...and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed...

Page 5: ...nt draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space...

Page 6: ...to adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilatio...

Page 7: ...urniture clothing or other flammable objects are less than 36 inches from the front top or sides of the heater as a fireplace insert in high traffic areas in windy or drafty areas WARNING Maintainthem...

Page 8: ...een screwhead and wall Attaching to Wall Anchor Method Follow instructions below to attach mounting screws to hollow walls wall areas between studs or solid walls concrete or masonry 1 Drill holes at...

Page 9: ...id pe troleum LP gas Installationmustincludeanequipmentshutoff valve ground joint union and plugged 1 8 NPTtap LocateNPTtapwithinreachfortest gauge hook up NPT tap must be upstream from heater see Fig...

Page 10: ...d on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 14 Apply mixture of liquid soap and wa ter...

Page 11: ...ight pilot The pilot is attached to the front of burner If needed keep pressingignitorbuttonuntilpilotlights Ignitor Electrode WARNING When running heater set control knob at LOW or HIGH locked positi...

Page 12: ...rect as shown in Figure 19 turn heater off see To Turn Off Gas to Appliance page 11 see Troubleshooting pages 13 through 15 GRH OV 008 BAD PILOT LP Figure 18 Correct Pilot Flame Pattern Thermocouple F...

Page 13: ...go out This prob lem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor...

Page 14: ...imilar products TROUBLESHOOTING Continued OBSERVED PROBLEM Burner s does not light after ODS pilot is lit Delayed ignition of burner s Burner backfiring during combustion Burner plaque s does not glow...

Page 15: ...r burning vapors from paint hair spray glues etc see IMPORTANT statement above 2 Gas leak SeeWarning statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is par...

Page 16: ...ernational When Gas Pressure Is Too Low pilot will not stay lit burner s will have delayed ignition heater will not produce specified heat When Gas Quality Is Bad pilot will not stay lit burner s will...

Page 17: ...553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 sales portableheaterparts com techservice portableheate...

Page 18: ...18 104276 NATURAL GAS HEATER CGN10RLA ILLUSTRATED PARTS BREAKDOWN CGN10RLA ODS PILOT 19 18 17 16 15 14 13 10 12 9 9 11 20 7 8 6 6 5 4 3 2 1 21 22 23 23 A B 7 2 7 1...

Page 19: ...01 Thermocouple 1 7 2 098594 01 Ignitor Electrode 1 8 099884 02 Burner Assembly 1 9 099056 06 Injector 2 10 099390 02 Tubing Valve to plaque A 1 11 099387 05 Pilot Tubing Valve to pilot 1 12 099392 01...

Page 20: ...airing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND...

Reviews: