background image

2

104276

NATURAL GAS HEATER

 CGN10RLA

SAFETY
INFORMATION

 

 

WARNINGS

1.

This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.

2.

If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do

not use any phone in your building

• immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions

• if you cannot reach your gas supplier,

call the fire department

3.

This heater shall not be installed in a
bathroom.

4.

Always run heater with control knob
at LOW or HIGH locked positions.
Never set control knob between locked
positions. Poor combustion and higher
levels of carbon monoxide may result.

5.

This heater needs fresh, outside air ven-
tilation to run properly. This heater has
an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS shuts
down the heater if not enough fresh air
is available. See Air for Combustion
and Ventilation,
 pages 4 through 6.

6.

Keep all air openings in front and bot-
tom of heater clear and free of debris.
This will insure enough air for proper
combustion.

7.

If heater shuts off, do not relight until
you provide fresh, outside air. If heater
keeps shutting off, have it serviced.

8.

Do not run heater
• where flammable liquids or vapors

are used or stored

• under dusty conditions

9.

Before using furniture polish, wax, car-
pet cleaner, or similar products, turn
heater off. If heated, the vapors from
these products may create a white pow-
der residue within burner box or on
adjacent walls or furniture.

10. Do not use heater if any part has been

under water. Immediately call a quali-
fied service technician to inspect the
room heater and to replace any part of
the control system and any gas control
which has been under water.

11. Turn off heater and let cool before ser-

vicing. Only a qualified service person
should service and repair heater.

12. Operating heater above elevations of

4,500 feet could cause pilot outage.

 WARNING: Any change to

this heater or its controls can be
dangerous.

Carbon Monoxide Poisoning:

 Early signs of

carbon monoxide poisoning resemble the flu,
with headaches, dizziness, or nausea. If you
have these signs, the heater may not be work-
ing properly. Get fresh air at once! Have
heater serviced. Some people are more af-
fected by carbon monoxide than others. These
include pregnant women, people with heart or
lung disease or anemia, those under the influ-
ence of alcohol, and those at high altitudes.

Natural Gas:

 Natural gas is odorless. An

odor-making agent is added to natural gas.
The odor helps you detect a natural gas leak.
However, the odor added to natural gas can
fade. Natural gas may be present even though
no odor exists.

Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this heater.

 DANGER: Carbon monoxide

poisoning may lead to death!

IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, oper-
ate, or service this heater. Im-
proper use of this heater can
cause serious injury or death from
burns, fire, explosion, and car-
bon monoxide poisoning.

Do not place clothing or other
flammable material on or near
the appliance. Never place any
objects on the heater.

Surface of heater becomes very
hot when running heater. Keep
children and adults away from
hot surface to avoid burns or
clothing ignition. Heater will re-
main hot for a time after shut-
down. Allow surface to cool be-
fore touching.

Carefully supervise young chil-
dren when they are in the same
room with heater.

Make sure grill guard is in place
before running heater.

Keep the appliance area clear and
free from combustible materials,
gasoline, and other flammable
vapors and liquids.

Due to high temperatures, the
appliance should be located out
of traffic and away from furniture
and draperies.

 WARNING: Do not use any

accessory not approved for use
with this heater.

Summary of Contents for Comfort Glow CGN10RLA

Page 1: ...alified installer service agency or the gas supplier WARNING Thisisanunvented gas firedheater Itusesair oxy gen from the room in which it is installed Provisions for ad equate combustion and venti lat...

Page 2: ...ser vicing Only a qualified service person should service and repair heater 12 Operating heater above elevations of 4 500 feet could cause pilot outage WARNING Any change to this heater or its control...

Page 3: ...Protection Association Inc Batterymarch Park Quincy MA 02269 UNPACKING 1 Remove heater from carton 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any shipping da...

Page 4: ...and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed...

Page 5: ...nt draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space...

Page 6: ...to adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilatio...

Page 7: ...urniture clothing or other flammable objects are less than 36 inches from the front top or sides of the heater as a fireplace insert in high traffic areas in windy or drafty areas WARNING Maintainthem...

Page 8: ...een screwhead and wall Attaching to Wall Anchor Method Follow instructions below to attach mounting screws to hollow walls wall areas between studs or solid walls concrete or masonry 1 Drill holes at...

Page 9: ...id pe troleum LP gas Installationmustincludeanequipmentshutoff valve ground joint union and plugged 1 8 NPTtap LocateNPTtapwithinreachfortest gauge hook up NPT tap must be upstream from heater see Fig...

Page 10: ...d on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 14 Apply mixture of liquid soap and wa ter...

Page 11: ...ight pilot The pilot is attached to the front of burner If needed keep pressingignitorbuttonuntilpilotlights Ignitor Electrode WARNING When running heater set control knob at LOW or HIGH locked positi...

Page 12: ...rect as shown in Figure 19 turn heater off see To Turn Off Gas to Appliance page 11 see Troubleshooting pages 13 through 15 GRH OV 008 BAD PILOT LP Figure 18 Correct Pilot Flame Pattern Thermocouple F...

Page 13: ...go out This prob lem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor...

Page 14: ...imilar products TROUBLESHOOTING Continued OBSERVED PROBLEM Burner s does not light after ODS pilot is lit Delayed ignition of burner s Burner backfiring during combustion Burner plaque s does not glow...

Page 15: ...r burning vapors from paint hair spray glues etc see IMPORTANT statement above 2 Gas leak SeeWarning statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is par...

Page 16: ...ernational When Gas Pressure Is Too Low pilot will not stay lit burner s will have delayed ignition heater will not produce specified heat When Gas Quality Is Bad pilot will not stay lit burner s will...

Page 17: ...553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 sales portableheaterparts com techservice portableheate...

Page 18: ...18 104276 NATURAL GAS HEATER CGN10RLA ILLUSTRATED PARTS BREAKDOWN CGN10RLA ODS PILOT 19 18 17 16 15 14 13 10 12 9 9 11 20 7 8 6 6 5 4 3 2 1 21 22 23 23 A B 7 2 7 1...

Page 19: ...01 Thermocouple 1 7 2 098594 01 Ignitor Electrode 1 8 099884 02 Burner Assembly 1 9 099056 06 Injector 2 10 099390 02 Tubing Valve to plaque A 1 11 099387 05 Pilot Tubing Valve to pilot 1 12 099392 01...

Page 20: ...airing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND...