background image

7

107187

OWNER’S MANUAL

For more information, visit www.desatech.com

You can recess firebox into the wall. You
can also position fireplace in the optional
cabinet mantels. 

IMPORTANT:

 Only use

optional cabinet mantels specified in this
manual. Purchase the optional mantel from
your dealer (see Accessories, page 26).

 CAUTION: This fireplace cre-

ates warm air currents. These cur-
rents move heat to wall surfaces
next to fireplace. Installing fire-
place next to vinyl or cloth wall
coverings or operating fireplace
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.) in
the air exist, may discolor walls.

 WARNING: Never install the

fireplace
• in a bedroom or a bathroom
• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the fireplace

• as a fireplace insert
• in high traffic areas
• in windy or drafty areas

IMPORTANT:

 Vent-free fireplaces add mois-

ture to the air. Although this is beneficial,
installing fireplace in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Combus-
tion and Ventilation, 
pages 4 through 6.

LOCATING FIREPLACE

 WARNING: Maintain the mini-

mum clearances shown in Fig-
ures 4 and 5. If you can, provide
greater clearances from floor,
ceiling, and joining wall.

 CAUTION: If you install the

fireplace in a home garage
• fireplace pilot and burner must

be at least 18 inches above
floor.

• locate fireplace where moving

vehicle will not hit it.

For convenience and efficiency, install fire-
place

• where there is easy access for operation,

inspection, and service.

• in coldest part of room.

An optional blower kit is available from
your dealer. See Accessories, page 26. If
planning to use blower, locate fireplace near
an electrical outlet.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply
is not propane/LP, do not install fireplace.
Call dealer where you bought fireplace for
proper type fireplace.

INSTALLATION ITEMS

Before installing fireplace, make sure you
have the items listed below.

• external regulator (supplied by installer)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• ground joint union

• sediment trap

• tee joint

• pipe wrench

• test gauge connection*

*  A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-
chase the optional CSA design-certified
equipment shutoff valve from your dealer.
See Accessories, page 26.

Note:

 If desired, purchase a four-sided brass

trim kit for built-in installations. See Acces-
sories, pag
e 26.

Continued

INSTALLATION

Continued

Figure 5- Mounting Clearances As Viewed
From Front of Fireplace Shown with
Optional Mantel

Figure 4 - Mounting Clearances As Viewed
From Front of Fireplace Shown Built In
The Wall

6"

Minimum
From
Sides Of
Fireplace

Left
Side

CEILING

42" Minimum

FLOOR

Right
Side

Top Of
Mantel Can
Be Flush
With Wall

Left
Side

CEILING

Right
Side

42"

Minimum

0" Minimum Clearance
To Top Surface Of
Carpeting, Tile Or Other
Combustible Material

Note:

 When installing fireplace directly on

carpeting, tile or other combustible mate-
rial, other than wood flooring, the fireplace
shall be installed on a metal or wood panel
extending the full width and depth of th
fireplace.

0" Minimum Clearance
To Top Surface Of
Carpeting, Tile Or Other
Combustible Material

Summary of Contents for Comfort Glow CF26PT

Page 1: ...ice agency or the gas supplier WARNING Improperinstallation adjustment alteration service ormaintenancecancauseinjury orpropertydamage Refertothis manual for correct installation andoperationalprocedu...

Page 2: ...call a qualified service per son Note Duringinitialoperation slight smokingcouldoccurduetologcuringand fireplaceburningmanufacturingresidues 8 To prevent the creation of soot follow the instructions...

Page 3: ...f fireplace is damaged promptly inform dealer where you bought fireplace PRODUCT FEATURES SAFETY PILOT This fireplace has a pilot with an Oxygen DepletionSensing ODS safetyshutoffsys tem The ODS pilot...

Page 4: ...This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombustionandven tilation air Read the following in structions to insure pro...

Page 5: ...gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ___________ Btu Hr...

Page 6: ...Attic AIR FOR COMBUSTION AND VENTILATION Continued Figure 2 Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefr...

Page 7: ...where there is easy access for operation inspection and service in coldest part of room An optional blower kit is available from your dealer See Accessories page 26 If planningtouseblower locatefirepl...

Page 8: ...ing 5 Attach flexible gas line to fireplace gas regulator See Connecting Fireplace to Gas Supply page 13 6 If the optional blower has been installed connect blower to electrical source Option one Rout...

Page 9: ...e 2 screws attaching brick liner retainers to vertical sides 2 Removebricklinerretainersanddiscard Replace 2 screws into vertical sides Figure 10 Assembling Brass Trim Top Brass Trim Side Brass Trim M...

Page 10: ...ld Cover Wire Harness Switch Plate Switch Heat Deflector Wiring Routing Hole Blue Red CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improperanddangerou...

Page 11: ...l not be used in built in installations Pop intheplasticsnapbushingfoundinhard warekitintotheholeleftbysupplycord strain relief 4 A licensed electrician must follow the wiring diagram in Figure 19 to...

Page 12: ...PT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from fireplace see Figure 21 IMPORTANT Install equipment shutoff valve in an accessible location The equip ment shuto...

Page 13: ...e seeFigure23 The flexible gas supply line con nection to the equipment shutoff valve should be accessible Equipment Shut Off Valve 2 Apply pipe joint sealant lightly to male threads of gas connector...

Page 14: ...ng or servicing Cor rect all leaks at once WARNING Neveruseanopen flame to check for a leak Apply a noncorrosiveleakdetectionfluid toalljoints Bubblesformingshow a leak Correct all leaks at once CAUTI...

Page 15: ...U shaped Cutout in Chassis Chassis WARNING If you do not fol low these instructions exactly a fireorexplosionmayresultcaus ing property damage personal injury or loss of life A This appliance has a p...

Page 16: ...ocedure OPERATING FIREPLACE Continued CAUTION Donottrytoadjust heatinglevelsbyusingtheequip ment shutoff valve Figure 29 Pilot Thermocouple Ignitor Electrode Pilot Burner TO TURN OFF GAS TO APPLIANCE...

Page 17: ...ld soap and water mixture Wipe the cabi net to remove dust CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas This...

Page 18: ...Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut i...

Page 19: ...r a few hours of operation 1 Refer to Air for Combustion and Venti lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from...

Page 20: ...es a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during...

Page 21: ...rton 28 x 26 13 16 x 16 1 2 Weight pounds Fireplace 44 1 2 lbs Shipping 55 lbs For purposes of input adjustment REPLACEMENT PARTS Note Use only original replacement parts This will protect your warran...

Page 22: ...2 107187 VENT FREE PROPANE LP BAY FRONT FIREPLACE CF26PT For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN CF26PT 12 9 10 11 5 16 20 18 1 2 4 7 6 19 8 21 13 19 14 19 19 3 15 17 1...

Page 23: ...embly 1 4 102844 02 Lower Bracket 1 5 102966 02 Upper Bracket 1 6 098867 10 Gas Regulator 1 7 102981 01 Inlet Tube 1 8 102983 04 Outlet Burner Tube 1 9 099056 29 Burner Orifice Injector 1 10 102843 01...

Page 24: ...REE PROPANE LP BAY FRONT FIREPLACE CF26PT For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN CF26PT 5 8 15 17 13 14 11 2 11 1 19 4 12 16 10 6 5 9 1 2 18 7 20 2 20 3 20 1 18 18 16...

Page 25: ...ly 1 12 101386 02 Hinge 2 13 099194 11 Rivets 8 14 105262 01CK Louvered Door 1 15 105261 01CK Firebox Floor 1 16 098304 01 Screw 10 x 3 8 21 17 105256 01CK Bayfront Bottom Panel 1 18 107992 01 Hex Hea...

Page 26: ...ng rough edges of wall opening CLEANING KIT CCK Not Shown Your vent free gas appliance requires regu lar cleaning and maintenance to prevent performance problems This kit gives you the tools and instr...

Page 27: ...ted Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 000 to 49 999 50 000 to 7...

Page 28: ...28 107187 VENT FREE PROPANE LP BAY FRONT FIREPLACE CF26PT For more information visit www desatech com 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TM...

Page 29: ...st Chester PA 19382 4500 610 430 7717 1 800 368 0803 www halcoenterprises com Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater P...

Page 30: ...efects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner T...

Reviews: