VENT-FREE PROPANE/LP BAY FRONT FIREPLACE

 CF26PT

For more information, visit www.desatech.com

INSTALLATION

Note: 

Your Comfort Glow fireplace is de-

signed to be used in zero clearance installa-
tions. Wall or framing material can be placed
directly against any exterior surface of your
fireplace, except where standoff spacers are
integrally attached. If standoff spacers are
attached to your fireplace, these spacers can
be placed directly against wall or framing
materials.

Use the dimensions shown for rough open-
ings to create the easiest installation (see
Built-In Fireplace Installation, page 8).

 WARNING: A qualified ser-

vice person must install fireplace.
Follow all local codes.

NOTICE: This heater is intended
for use as  supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

Figure 3 - Ventilation Air from Outdoors Shown with Optional Mantel

Outlet
Air

Ventilated
Attic 

Outlet
Air

Inlet
Air

Inlet Air

Ventilated 

Crawl Space

To 

Crawl

Space

To Attic

AIR FOR
COMBUSTION AND
VENTILATION

Continued

Figure 2 - Ventilation Air from Inside Building Shown with Optional Mantel

VENTILATION AIR

Ventilation Air From Inside
Building

This fresh air would come from an adjoining
unconfined space. When ventilating to an
adjoining unconfined space, you must pro-
vide two permanent openings: one within
12" of the ceiling and one within 12" of the
floor on the wall connecting the two spaces
(see options 1 and 2, Figure 2). You can also
remove door into adjoining room (see op-
tion 3, Figure 2). Follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Section
5.3, Air for Combustion and Ventilation
 for
required size of ventilation grills or ducts.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation
grills or ducts. You must provide two per-
manent openings: one within 12" of the
ceiling and one within 12" of the floor.
Connect these items directly to the outdoors
or spaces open to the outdoors. These spaces
include attics and crawl spaces. Follow the
National Fuel Gas Code, ANSI Z223.1/
NFPA 54, Section 5.3, Air for Combustion
and Ventilation
 for required size of ventila-
tion grills or ducts.

IMPORTANT: 

Do not provide openings for

inlet or outlet air into attic if attic has a
thermostat-controlled power vent. Heated air
entering the attic will activate the power vent.

Or 

Remove 

Door into 
Adjoining 

Room, 

Option 3

Ventilation Grills 

Into Adjoining Room,

Option 2

12"

12"

Ventilation

Grills

into Adjoining

Room, 

Option 1

Summary of Contents for Comfort Glow CF26PT

Page 1: ...ice agency or the gas supplier WARNING Improperinstallation adjustment alteration service ormaintenancecancauseinjury orpropertydamage Refertothis manual for correct installation andoperationalprocedu...

Page 2: ...call a qualified service per son Note Duringinitialoperation slight smokingcouldoccurduetologcuringand fireplaceburningmanufacturingresidues 8 To prevent the creation of soot follow the instructions...

Page 3: ...f fireplace is damaged promptly inform dealer where you bought fireplace PRODUCT FEATURES SAFETY PILOT This fireplace has a pilot with an Oxygen DepletionSensing ODS safetyshutoffsys tem The ODS pilot...

Page 4: ...This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombustionandven tilation air Read the following in structions to insure pro...

Page 5: ...gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ___________ Btu Hr...

Page 6: ...Attic AIR FOR COMBUSTION AND VENTILATION Continued Figure 2 Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefr...

Page 7: ...where there is easy access for operation inspection and service in coldest part of room An optional blower kit is available from your dealer See Accessories page 26 If planningtouseblower locatefirepl...

Page 8: ...ing 5 Attach flexible gas line to fireplace gas regulator See Connecting Fireplace to Gas Supply page 13 6 If the optional blower has been installed connect blower to electrical source Option one Rout...

Page 9: ...e 2 screws attaching brick liner retainers to vertical sides 2 Removebricklinerretainersanddiscard Replace 2 screws into vertical sides Figure 10 Assembling Brass Trim Top Brass Trim Side Brass Trim M...

Page 10: ...ld Cover Wire Harness Switch Plate Switch Heat Deflector Wiring Routing Hole Blue Red CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improperanddangerou...

Page 11: ...l not be used in built in installations Pop intheplasticsnapbushingfoundinhard warekitintotheholeleftbysupplycord strain relief 4 A licensed electrician must follow the wiring diagram in Figure 19 to...

Page 12: ...PT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from fireplace see Figure 21 IMPORTANT Install equipment shutoff valve in an accessible location The equip ment shuto...

Page 13: ...e seeFigure23 The flexible gas supply line con nection to the equipment shutoff valve should be accessible Equipment Shut Off Valve 2 Apply pipe joint sealant lightly to male threads of gas connector...

Page 14: ...ng or servicing Cor rect all leaks at once WARNING Neveruseanopen flame to check for a leak Apply a noncorrosiveleakdetectionfluid toalljoints Bubblesformingshow a leak Correct all leaks at once CAUTI...

Page 15: ...U shaped Cutout in Chassis Chassis WARNING If you do not fol low these instructions exactly a fireorexplosionmayresultcaus ing property damage personal injury or loss of life A This appliance has a p...

Page 16: ...ocedure OPERATING FIREPLACE Continued CAUTION Donottrytoadjust heatinglevelsbyusingtheequip ment shutoff valve Figure 29 Pilot Thermocouple Ignitor Electrode Pilot Burner TO TURN OFF GAS TO APPLIANCE...

Page 17: ...ld soap and water mixture Wipe the cabi net to remove dust CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas This...

Page 18: ...Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut i...

Page 19: ...r a few hours of operation 1 Refer to Air for Combustion and Venti lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from...

Page 20: ...es a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during...

Page 21: ...rton 28 x 26 13 16 x 16 1 2 Weight pounds Fireplace 44 1 2 lbs Shipping 55 lbs For purposes of input adjustment REPLACEMENT PARTS Note Use only original replacement parts This will protect your warran...

Page 22: ...2 107187 VENT FREE PROPANE LP BAY FRONT FIREPLACE CF26PT For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN CF26PT 12 9 10 11 5 16 20 18 1 2 4 7 6 19 8 21 13 19 14 19 19 3 15 17 1...

Page 23: ...embly 1 4 102844 02 Lower Bracket 1 5 102966 02 Upper Bracket 1 6 098867 10 Gas Regulator 1 7 102981 01 Inlet Tube 1 8 102983 04 Outlet Burner Tube 1 9 099056 29 Burner Orifice Injector 1 10 102843 01...

Page 24: ...REE PROPANE LP BAY FRONT FIREPLACE CF26PT For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN CF26PT 5 8 15 17 13 14 11 2 11 1 19 4 12 16 10 6 5 9 1 2 18 7 20 2 20 3 20 1 18 18 16...

Page 25: ...ly 1 12 101386 02 Hinge 2 13 099194 11 Rivets 8 14 105262 01CK Louvered Door 1 15 105261 01CK Firebox Floor 1 16 098304 01 Screw 10 x 3 8 21 17 105256 01CK Bayfront Bottom Panel 1 18 107992 01 Hex Hea...

Page 26: ...ng rough edges of wall opening CLEANING KIT CCK Not Shown Your vent free gas appliance requires regu lar cleaning and maintenance to prevent performance problems This kit gives you the tools and instr...

Page 27: ...ted Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 000 to 49 999 50 000 to 7...

Page 28: ...28 107187 VENT FREE PROPANE LP BAY FRONT FIREPLACE CF26PT For more information visit www desatech com 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TM...

Page 29: ...st Chester PA 19382 4500 610 430 7717 1 800 368 0803 www halcoenterprises com Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater P...

Page 30: ...efects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner T...

Reviews: