LIMITED WARRANTY

VENT-FREE GAS BAY FRONT FIREPLACE

DESA Heating Products warrants this product to be free from defects in materials and components for two (2) 

years from the date of first purchase, provided that the product has been properly installed, operated and maintained 

in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled 

check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required 

to restore this fireplace to proper operating condition and an allowance for labor when provided by a DESA 

Heating Products Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of 

this product and/or DESA Heating Products who will provide original factory replacement parts. Failure to use 

original factory replacement parts voids this warranty. The fireplace MUST be installed by a qualified installer in 

accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts 

that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by 

improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to 

repairing a defective fireplace will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE 

OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED 

WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUD

-

ING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO 

(2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA HEATING 

PRODUCTS’ LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND 

DESA HEATING PRODUCTS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER 

INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of 

incidental or consequential damages, so the above limitation on implied warranties or exclusion or limitation on 

damages may not apply to you.

This warranty gives you specific legal rights and you may also have other rights that vary from state to state.
For information about this warranty write:

701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 410-9004
www.desatech.com

113896-01
Rev. D
05/06

NOT A UPC

WARRANTY INFORMATION

kEEP THIS WARRANTY

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our 

standard written warranty. We make no other warranty, expressed or implied.

113896 01

f i r e - p a r t s . c o m

Summary of Contents for Comfort Glow CF26NTA

Page 1: ...y phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and serv...

Page 2: ...s an unvented gas fired heat er It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven ti...

Page 3: ...rtain you read and understand all warn ings Keep this manual for reference It is your guide to safe and proper operation of this heater WARNING Any change to this heater or its controls can be dangero...

Page 4: ...tilation to run properly This fireplace has an Oxygen Deple tion Sensing ODS safety shutoff system The ODS shuts down the fireplace if not enough fresh air is available See Air for Combustion and Vent...

Page 5: ...s are built more energy efficient than ever New materials increased insulation and new construction methods help reduce heat loss in homes Home owners weather strip and caulk around windows and doors...

Page 6: ...re considered a part of the uncon fined space Adjoining rooms are communicating only if there are doorless DETERMINING FRESH AIR FLOW FOR Fireplace LOCATION Determining if You Have a Confined or Uncon...

Page 7: ...two perma nent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see...

Page 8: ...e minimum clearances shown in Figure4and5 page9 Ifyoucan providegreaterclearancesfrom floor ceiling and joining wall You can recess firebox into the wall You can also position fireplace in the optiona...

Page 9: ...42 365 8 257 8 513 4 267 8 Figure 6 Rough Opening for Installing in Corner 267 8 267 8 3 4 Off The Floor Minimum 10 1 2 Figure 5 Rough Opening for Installing in Wall Figure 4 Minimum Clearance for Co...

Page 10: ...the firebox front facing IMPORTANT Noncombustible materials such as brick tile etc may overlap the front facing but should never cover any necessary openings like louvered slots WARNING Do not allow n...

Page 11: ...shim in slot on mitered edge of side trim see Figure 9 6 While firmly holding edges of trim together tighten both set screws on the adjusting plate with slotted screwdriver 7 Repeat steps 1 through 6...

Page 12: ...nnection when servicingcontrols Wiringerrors cancauseimproperanddanger ous operation CAUTION Verify proper op eration after servicing Note If you are using a mantel with your heater use the following...

Page 13: ...onnect red wire to theAUTO switch posi tion Reconnect blue wire to the ON switch position Reconnect green and white wires to the power cord 10 Install the switch plate on the blower control shield wit...

Page 14: ...not included Outlet Receptacle Strain Relief Blue Red 1 Install a snap bushing found in hardware kit into one of the holes found on rear of blower control shield The other hole is for a strain relief...

Page 15: ...ent trap tee joint pipe wrench test gauge connection ACSAdesign certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA desig...

Page 16: ...ied equipment shutoff valve from your dealer See Accessories page 27 Minimum inlet pressure for purpose of input adjustment 3 Minimum Gas Control Propane LP From External Regulator 11 W C to 14 W C Pr...

Page 17: ...l valve and equipment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where equipment shutoff valve was connecte...

Page 18: ...ernal joints for leaks 7 Turn off heater see To Turn Off Gas to Appli ance page 21 8 Replace front panel INSTALLING LOGS WARNING Failure to posi tion the parts in accordance with these diagrams or fai...

Page 19: ...shutoff valve is fully open 3 Turn control knob clockwise to the OFF position 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in...

Page 20: ...E 1 Follow steps 1 through 6 under Lighting Instructions page 19 2 Depress control knob and light pilot with match 3 Keep control knob pressed in for30 seconds after lighting pilot After 30 seconds re...

Page 21: ...t hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner repeat steps 3 an...

Page 22: ...1 Ignitor electrode not con nected to ignitor cable 2 Ignitor cable pinched or wet 3 Piezo ignitor nut is loose 4 Broken ignitor cable 5 Bad piezo ignitor 6 Ignitor electrode positioned wrong 7 Ignito...

Page 23: ...toff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT position 4 Continue holding down con trol knob Repeat igniting op eration until air is removed 5 Contact local p...

Page 24: ...rner for dirt and debris If found clean burner see Cleaning and Mainte nance page 21 2 Replace gas control 3 Problem will stop after a few hours of operation 1 Refer to Air for Combustion and Ventilat...

Page 25: ...DS pilot seeCleaning and Maintenance page 21 1 Locate and correct all leaks see Checking Gas Connec tions page 17 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2 Locate and...

Page 26: ...call DESA Heating Products at 1 866 672 6040 for referral information When calling DESA Heating Products have ready model number of your heater the replacement part number Parts Central These Parts C...

Page 27: ...SE Not Shown GMC83F Oak Finished Georgian Design CS26CP Black Red Oak Cottage Design GMC63UD Unfinished Traditional Design CMA208FB Light Oak Finished Traditional Design For all models Space saving ma...

Page 28: ...www desatech com 113896 01D 28 Illustrated Parts Breakdown Models CF26PTA and CF26NTA 12 9 10 11 16 20 18 1 8 5 4 7 6 19 13 19 14 2 19 19 3 15 17 19 fire parts com...

Page 29: ...nlet Tube 1 8 102983 06 Outlet Burner Tube 1 111331 08 Outlet Burner Tube 1 9 099056 29 Burner Orifice Injector 1 099056 20 Burner Orifice Injector 1 10 111124 01 Burner Retainer Spring 1 11 102980 01...

Page 30: ...www desatech com 113896 01D 30 ILLUSTRATED PARTS BREAKDOWN Models CF26PTA and CF26NTA 5 8 15 17 13 14 11 2 11 1 19 4 12 16 10 6 5 9 1 2 18 7 20 2 20 3 20 1 18 18 16 21 3 18 16 3 21 fire parts com...

Page 31: ...1 8 Bay Front Base 1 9 105421 01 Heat Deflector 1 10 105409 01 Fan Control Shield 1 11 1 105401 01 Screen Rod 1 11 2 105440 01 Screen Assembly 1 12 101386 02 Hinge 2 13 Rivets 8 14 105262 01CK Louver...

Page 32: ...ts related to repairing a defective fireplace will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRAN...

Reviews: