www.desatech.com
120890-01D
25
Glass Doors
Figure 31 - Installing Thermostat Sensing
Bulb behind Glass Doors
Thermostat
Sensing Bulb
Adhesive-
backed
Mounting Clip
4. Mounting clip must be a minimum of 3"
from bottom of fireplace to prevent crimp
-
ing of capillary. Once you have decided
on a location, clean area thoroughly.
Remove paper backing from adhesive on
back of mounting clip. Press clip into new
location so thermostat sensing bulb will
be positioned vertically with capillary at
bottom (see Figure 32). Slide thermostat
sensing bulb into clip.
IMPORTANT:
Do not crimp capillary.
OPTIONAL POSITIONING OF THERMOSTAT
SENSING BULB
Continued
Capillary
Thermostat
Sensing Bulb
Do Not Crimp
Capillary
Adhesive-
backed
Mounting Clip
Figure 32 - Positioning Thermostat
Sensing Bulb in Vertical Position with
Capillary at Bottom
SPEcIFIcATIONS
Model CLD3924PTC
• Rating (Variable): 20,000/39,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Piezo
• Pressure Manifold: 8.0" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 14" W.C., Minimum* 11" W.C.
• Shipping Weight:
27 lbs.
* For input adjustment
Model CLD3924NTC
• Rating (Variable): 20,000/39,000 Btu/Hr
• Type Gas : Natural Gas
• Ignition: Piezo
• Pressure Manifold: 3.5" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 10.5" W.C., Minimum* 5" W.C.
• Shipping Weight:
29 lbs.