background image

www.desatech.com

119732-01A

5

RePlACING HeATeR/BlOWeR 
ASSeMBly

The heater/blower assembly is located behind 

the top panel on back of stove (see Figure 4). 

The top of stove, top back panel and bottom back 

panel must be removed to access heater/blower 

assembly.

1.  Remove 4 screws from top of heater located 

under top side edges (see Figure 4).

2.  Remove screws holding bottom back panel 

and top back panel. Do not stress wires that 

are attached to top panel. 

3.  Remove 4 screws from top plate to remove 

heater/blower assembly (see Figure 5).

4.  Disconnect wires from heater/blower assem-

bly motor.

5.  Reconnect  wires  to  new  heater/blower 

assembly.

CLEANING ANd 

MAINTENANCE

Continued

Figure 4 - Screw Locations

Screws

Screws

Screws 
for Top 
of Stove

Screw

Screw

Screws 
for Top 
of Stove

6.  Install heater/blower assembly under top plate 

using screws removed in step 3.

7.  Replace top and bottom back panels using 

screws removed in steps 2 and 3.

8.  Replace top of stove using screws removed in 

step 1.

RePlACING BACK GlASS

The top of stove, top back panel and bottom back 

panel must be removed to access heater/blower 

assembly.

1.  Remove 4 screws from top of heater located 

under top side edges (see Figure 4).

2.  Remove screws holding bottom back panel 

and top back panel. Do not stress wires that 

are attached to top panel. 

3.  Remove 4 screws from top plate to remove 

heater/blower assembly (see Figure 5).

4.  Disconnect wires from heater/blower assem-

bly motor.

5.  Remove 2 screws and metal brackets at top of 

glass (see Figure 6).

6.  Carefully remove glass.

7.  Carefully insert new glass. Glass will rest 

on brackets located on sides of stove (see 

Figure 6).

8.  Replace small brackets and screws removed 

in step 5.

9.  Reconnect wires to heater/blower assembly.

10.  Install heater/blower assembly under top plate 

using screws removed in step 3.

11.  Replace top and bottom back panels using 

screws removed in steps 2 and 3.

12.  Replace top of stove using screws removed in 

step 1.

Figure 5 - Blower Screw Locations

Screws Attaching 
Blower to Top Plate

Blower

Front of Stove

Top Back Panel

Bottom Back Panel

Figure 6 - Glass Retaining Screw and 

Bracket Location

Glass Retaining Screw 
and Metal Bracket

Glass

Glass Rests 
on Brackets

Remove Screw 
to Remove Log

Summary of Contents for CGESSA

Page 1: ...stove Failure to follow them could cause a heater malfunction resulting in serious injury and or property damage Save this manual for future reference For more information visit www desatech com ELECTRIC STOVE Model CGESSA SAFETY INFORMATION AND OPERATION MANUAL ...

Page 2: ...is damaged or has mal functioned If you suspect the unit is damaged return it to an authorized service facility for examination electrical or mechanical adjust ment or repair 6 Do not use this unit outdoors 7 Do not use or install this unit in areas prone to dampness or where it may come into contact with water This heater is not intended for use in bathrooms laundry areas or other locations where...

Page 3: ...t CAUTION The unit s power supply cord must be connected to a properly grounded and pro tected120voltoutlet Alwaysuse ground fault protection where required by the electrical code WARNING Do not operate the unit if it is damaged or has malfunctioned Ifyoususpectthe unit is damaged return the unit to an authorized service facility for examination electrical or me chanical adjustment or repair Frequ...

Page 4: ...as a symbol of the sun directly below it 4 Thermostat Control Dial This dial is located at the furthest left corner on the control panel It has a symbol of a ther mostat directly below it Turn the dial clockwise past the number 8 You should hear a small clicking sound indicating Built In Thermostat Main Power Switch Flame Switch Heater Switch Grounding Pin Adapter the heater has started and heat w...

Page 5: ... top of stove top back panel and bottom back panel must be removed to access heater blower assembly 1 Remove 4 screws from top of heater located under top side edges see Figure 4 2 Remove screws holding bottom back panel and top back panel Do not stress wires that are attached to top panel 3 Remove 4 screws from top plate to remove heater blower assembly see Figure 5 4 Disconnect wires from heater...

Page 6: ...t If they can t supply original replacement part s call DESA Heating Products Technical Service Department at 1 866 672 6040 When calling DESA Heating Products have ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to the factory Parts Not Under Warranty Contact authorized dealers of this prod...

Page 7: ... follow the instructions listed under Replacement Parts on page 6 of this manual KEY NO PART NO DESCRIPTION QTY 1 119723 01 Stove Top 1 2 119724 01 Front Door Rods 2 3 119725 01 Front Door Panel with Glass 1 4 119726 01 Glass Mirror 1 5 119727 01 Lower Back Panel 1 6 119747 01 Upper Back Panel 1 7 119728 01 Log 1 8 119729 01 Heater Blower Assembly 1 9 119731 01 ON OFF Switches 3 10 119730 01 Legs ...

Page 8: ... or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLU...