SAFETY INFORMATION

 WARNING: Improper instal-

lation,  adjustment,  alteration, 

service  or  maintenance  can 

cause injury or property damage. 

Refer to this manual for further 

information.

 WARNING: Risk of fire - keep 

combustible material away from 

the front of the heater. Keep elec-

trical  cords,  drapery  and  other 

furnishings at least 3 feet from the 

front and sides of electric stove.

 WARNING: Servicing should 

be  done  only  while  the  heater 

is disconnected from the power 

supply circuit.

 WARNING: Any other use not 

recommended  or  described  in 

your owner’s manual may cause 

fire, burns, electric shock and/or 

other serious injuries or death.

Your electric stove is classified as an electric 

heater. As with any electrical appliance and par-

ticularly with electric heaters, basic precautions 

must be followed in order to reduce the risk of 

fire, burns, electrical shocks and/or other serious 

injuries or death.

1.  Read all instructions before using this heater.

2.  The unit can become hot when in use. To avoid 

accidental burns, do not allow skin to come into 

contact with the hot surfaces of the unit. Keep 

children and pets away from unit when in use.

3.  Keep combustible materials, such as furniture, 

pillows, bedding, papers, clothes and curtains 

at least 3 feet from heater. Do not use this unit 

in areas where gasoline, paint or other flam-

mable liquids or their associated vapors may 

be present.

4.  Do not use this unit for drying wet clothes.

5.  Do not operate unit if it is damaged or has mal-

functioned. If you suspect the unit is damaged, 

return it to an authorized service facility for 

examination, electrical or mechanical adjust-

ment or repair.

6.  Do not use this unit outdoors.

7.  Do not use or install this unit in areas prone to 

dampness or where it may come into contact 

with water. This heater is not intended for use 

in bathrooms, laundry areas or other locations 

where water may be present.

8.  To reduce the risk of fire, do not place or 

install this unit in areas where the ventilation 

or circulation ducts may become blocked.

9.  Do not insert or allow foreign objects to enter 

any of the ventilation or circulation ducts as 

this may cause electric shock, fire or otherwise 

damage the unit.

10. The unit's power supply cord must be con-

nected to a properly grounded and protected, 

120 volt electrical outlet. Always use ground 

fault protection where required by the electri-

cal code. To reduce the risk of fire, avoid run-

ning power supply cord under rugs, carpets, 

etc. Keep the power supply cord away from 

high traffic area where it may pose a tripping 

hazard.

11.  Avoid the use of an extension cord because the 

extension cord may overheat and cause a risk of 

fire. However, if you have to use an extension 

cord, the cord should be No. 14 AWG minimum 

size with a grounding plug and rated not less than 

1875 WATTS.

TAbLE OF CONTENTS

Safety Information ............................................... 2
Listing Approvals ................................................. 3
Unpacking and Testing the Unit ........................... 3
Product Dimensions & Specifications .................. 3
Grounding Instructions ........................................ 4
Operating Instructions ......................................... 4

Cleaning and Maintenance .................................. 4
Technical Service................................................. 6
Replacement Parts .............................................. 6
Troubleshooting ................................................... 6
Illustrated Parts Breakdown and Parts List.......... 7
Warranty Information ...........................Back Cover

Summary of Contents for CGESSA

Page 1: ...stove Failure to follow them could cause a heater malfunction resulting in serious injury and or property damage Save this manual for future reference For more information visit www desatech com ELECTRIC STOVE Model CGESSA SAFETY INFORMATION AND OPERATION MANUAL ...

Page 2: ...is damaged or has mal functioned If you suspect the unit is damaged return it to an authorized service facility for examination electrical or mechanical adjust ment or repair 6 Do not use this unit outdoors 7 Do not use or install this unit in areas prone to dampness or where it may come into contact with water This heater is not intended for use in bathrooms laundry areas or other locations where...

Page 3: ...t CAUTION The unit s power supply cord must be connected to a properly grounded and pro tected120voltoutlet Alwaysuse ground fault protection where required by the electrical code WARNING Do not operate the unit if it is damaged or has malfunctioned Ifyoususpectthe unit is damaged return the unit to an authorized service facility for examination electrical or me chanical adjustment or repair Frequ...

Page 4: ...as a symbol of the sun directly below it 4 Thermostat Control Dial This dial is located at the furthest left corner on the control panel It has a symbol of a ther mostat directly below it Turn the dial clockwise past the number 8 You should hear a small clicking sound indicating Built In Thermostat Main Power Switch Flame Switch Heater Switch Grounding Pin Adapter the heater has started and heat w...

Page 5: ... top of stove top back panel and bottom back panel must be removed to access heater blower assembly 1 Remove 4 screws from top of heater located under top side edges see Figure 4 2 Remove screws holding bottom back panel and top back panel Do not stress wires that are attached to top panel 3 Remove 4 screws from top plate to remove heater blower assembly see Figure 5 4 Disconnect wires from heater...

Page 6: ...t If they can t supply original replacement part s call DESA Heating Products Technical Service Department at 1 866 672 6040 When calling DESA Heating Products have ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to the factory Parts Not Under Warranty Contact authorized dealers of this prod...

Page 7: ... follow the instructions listed under Replacement Parts on page 6 of this manual KEY NO PART NO DESCRIPTION QTY 1 119723 01 Stove Top 1 2 119724 01 Front Door Rods 2 3 119725 01 Front Door Panel with Glass 1 4 119726 01 Glass Mirror 1 5 119727 01 Lower Back Panel 1 6 119747 01 Upper Back Panel 1 7 119728 01 Log 1 8 119729 01 Heater Blower Assembly 1 9 119731 01 ON OFF Switches 3 10 119730 01 Legs ...

Page 8: ... or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLU...

Reviews: