www.desatech.com
113183-01B
14
INSTALLATION
Continued
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 14).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve
located on or near gas meter for natural gas,
or using compressed air.
3. Check all joints from gas meter for natural or
propane/LP supply to equipment shutoff valve
(see Figure 15 or 16). Apply a noncorrosive
leak detection fluid to all joints. Bubbles form-
ing show a leak.
4. Correct all leaks at once.
PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 14).
2. Open main gas valve located on or near gas
meter for natural gas or open propane/LP
supply tank valve.
3. Make sure control knobs of heater are in the
OFF position.
4. Check all joints from equipment shutoff valve
to thermostat gas valve (see Figure 15 or 16).
Apply a noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
Figure 14 - Equipment Shutoff Valve
Figure 15 - Checking Gas Joints
(Propane/LP Gas Only)
Thermostat Gas
Valve or Control
Valve Location
Propane/LP
Supply Tank
Equipment Shutoff Valve
Open
Closed
Equipment
Shutoff
Valve
Figure 16 - Checking Gas Joints (Natural
Gas Only)
Thermostat Gas Valve or
Control Valve Location
Gas Meter
Equipment
Shutoff Valve
INSTALLING LOGS
WARNING: Failure to posi-
tion the parts in accordance with
these diagrams or failure to use
only parts specifically approved
with this heater may result in
property damage or personal
injury.
CAUTION: After installation
and periodically thereafter, check
to ensure that no yellow flame
comes in contact with any log.
With the heater set to HI, check to
see if flames contact any log. If so,
reposition logs according to the
log installation instructions in this
manual. Yellow flames contacting
logs will create soot.
It is very important to install the logs exactly as
instructed. Do not modify logs. Only use logs sup-
plied with heater. Before installing logs, make sure
log alignment screws are in place and straight.
6. Light heater (see
Operating Heater
, page 16).
Check all other internal joints for leaks.
7. Turn off heater (see
To Turn Off Gas to Appli-
ance
, page 17).