INSTALLATION

Continued

GAS LINE HOOK-UP

 WARNING: Gas line hook-up should be done by

your gas supplier or a qualified service person.

 WARNING: Before you proceed, make sure your

gas supply is OFF.

An equipment shutoff valve has been included in the fireplace's gas
supply system. However, consider installing an extra shutoff valve
outside the appliance’s enclosure (check local codes), where it can
be accessed more conveniently with a key through a wall as shown
in Figure 12.

In conformance with local codes, route a 1/2" NPT gas line towards
the appliance coming in from either the left or right side of the
fireplace (see Figure 13).

Install a sediment trap between the incoming gas line and the gas
control box. (see Figure 14). The sediment trap should extend down
a minimum of 3" (7.62 cm) beyond the center of the pipe.

When routing gas line through conduit sleeve, make sure to repack
insulation to fill gaps between gas line and conduit sleeve. Com-
pounds used on threaded joints of gas piping shall be resistant to the
action of propane or natural gas. Compounds should be applied
lightly to ensure excess sealant does not enter the gas line.

 WARNING: All gas piping and connections must

be tested for leaks after the installation is completed.

Never use an open flame to check for a leak. After
ensuring that the gas valve is open apply commercial
leak detection fluid to all gas joints. Bubbles forming
show a leak. Correct all leaks at once.

Do not operate any appliance if a leak is detected.

Figure 12- Typical Exterior Wall Gas Shutoff Installation

Key

Extension

Shutoff Valve

Figure 13 - Gas Line Routing

Figure 14 - Sediment Trap

PILOT ADJUSTMENT

The pilot or electrode assembly is factory preset for the proper flame
height. Alterations to these settings may have occurred during
shipping and handling. If this is the case, some minor readjustments
may be necessary and should be done by a qualified service
technician. The proper settings for the thermopile height should be
at a distance of 3/8" (.95 cm) to 1/2" (1.27 cm) from the pilot flame
as shown in Figure 15.

Figure 15 - Pilot Assembly

3" Min.

Sediment Trap
(Not Supplied)

Incoming 1/2" Gas
Line Permitted By
Local Codes

3" Min.

(7.6 cm)

1/8"

(0.3cm)

3/8" - 1/2"
(.95cm-1.3cm)

Complete your gas line installation by connecting the incoming
gas line to the flexible gas line. Secure tightly with a wrench but
do not over-tighten.

T

I

P

O

FF

T

O

L

ON

PI L O

T

P

T

H

T

P

T

H

Gas Routing
(Right Side Not Shown)

Side of
Fireplace

Front Face

INSTALLATION

Gas Line Hook-Up
Pilot Adjustment

Summary of Contents for CD32M

Page 1: ...or future reference For more information visit www desatech com For more information visit www desatech com DIRECT VENT FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL WARNING This direct vent gas fire place is intended for use with natural or propane LP gas only Do not at tempt to burn any solid fuels in this appliance WARNING Improper installation ad justment alteration service ormainte nanc...

Page 2: ...stalling this appliance The DESA Coleman warranty will be voided by and DESA Coleman disclaims any responsibility for the following actions A Modification to the fireplace components doors blower fans or vent system B Use of any component part not manufactured or approved by DESA Coleman in combination with a DESA Coleman fire place system Proper installation is the most important step in ensuring...

Page 3: ...chnician to examine the appli ance and to replace any part s of the control ignition system and other related components that have been submerged under water Figure 1 Common Fireplace Locations Flush installation is recommended where living space is limited Projected installation may be ideal for a new addition to an existing finished wall Corner installation makes use of a space that may not norm...

Page 4: ...8 ft 243 84 cm 3 ft 91 44 cm to 12 ft 365 76 cm 4 ft 121 92 cm to 16 ft 487 68 cm 5 ft 152 40 cm to 15 ft 457 20 cm 6 ft 182 88 cm to 14 ft 426 72 cm 7 ft 213 36 cm to 13 ft 396 24 cm 8 ft 243 84 cm to 12 ft 365 76 cm WARNING Never allow the vent to run downward as this may cause excessive temperatures which could cause a fire CD32M CD36M A CD42M A A 32 3 8 36 1 8 40 1 8 B 34 5 8 41 1 4 48 1 4 C 1...

Page 5: ...paved side walk or a paved driveway located on public property 84 inches 213 4cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum N clearance above a roof shall extend a minimum of 24 inches 61cm above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches 45 7cm vent shall not terminate directly above a si...

Page 6: ...all see Figure 7 Do not seal termination to vent pipe The vent termination must be removable for service pipe inspection 6 For vertical installation a vertical termination is available Also for vertical venting application install vertical flue restrictor into inner collar of fireplace as shown in Figure 6 When installing a length of pipe for vertical termination that is over 3 ft support the pipe...

Page 7: ...may be created Theapplianceanditsindividualshutoffvalvemustbedisconnected fromthegassupplypipingsystemduringanypressuretestingofthat system at test pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi...

Page 8: ...excess sealant does not enter the gas line WARNING All gas piping and connections must be tested for leaks after the installation is completed Never use an open flame to check for a leak After ensuring that the gas valve is open apply commercial leak detection fluid to all gas joints Bubbles forming show a leak Correct all leaks at once Do not operate any appliance if a leak is detected Figure 12 ...

Page 9: ...s very important to install these logs exactly as instructed Do not modify logs Only use logs supplied with fireplace Models CD32M and CD36M A Series 1 Place log 1 back log on top of grate as shown in Figure 18 Make sure notches in bottom of log fit over grate 2 Place log 2 large front log over pins on grate see Figure 19 Figure 18 Installing Log 1 Models CD32M CD36M A Series Figure 19 Installing ...

Page 10: ... Rest left side of log 2 front log on top of log 1 and right side onto pin located on right side of grate extension see Fig ure 24 3 Place log 3 rear log onto pins on rear of grate see Figure 25 4 Place log 4 crossover log onto pins from both logs 2 and 3 see Figure 26 5 Place log 5 top log onto right pin of front log 2 and smooth surface of rear log 3 Make sure it is seated properly see Figure 27...

Page 11: ...t be obstructed and upper and lower panels must remain accessible for service Use only heat resistant noncombustible mortar or adhesive when securing decorative facing materials FACE EXTENSION FOR MODEL CD32M ONLY Model CD32M comes equipped with a front face extension The front face extension would add 3 1 2 to the width and 3 4 to the height of the fireplace face To install face extension 1 Remov...

Page 12: ...rtment C Use only your hand to push in control knob Never use tools If the knob will not push in or slide by hand don t try to repair it call a qualified service technician Force or at tempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the c...

Page 13: ...o burner orifices 6 Remove pilot hood by pulling up until it disengages from bar rel Do not remove the retainer clip see Figure 34 7 Remove pilot orifice from inside barrel using a 5 32 allen wrench to unscrew the orifice 8 Replace pilot orifice with LPorifice supplied with this kit The number 30 is stamped on the sleeve for identification Insert small end of new pilot orifice into barrel and thre...

Page 14: ... N Mounting Screws Rubber Gasket Identification Label CONVERTING CONTROL VALVE Convert the gas control valve by swapping out the valve regulator portion of the gas valve 1 Using a TORX T20 or a slotted screwdriver remove and dis card the three mounting screws pressure regulator tower and diaphragm spring components see Figure 35 2 Insure that the rubber gasket is properly positioned on the new pre...

Page 15: ...ading at thermocouple ter minals of gas valve with remote control off It should read 18 millivolts mini mum Replace faulty thermocouple if reading is below specified minimum 1 Check remote wires for proper connec tions Place jumper wire across termi nals at remote control If burner comes on replace remote If okay place jumper wire across remote control at valve If burner comes on wires are faulty ...

Page 16: ...ww desatech com 16 6 7 19 18 10 12 23 24 34 2 11 17 8 21 2 21 6 21 4 21 5 21 3 21 1 1 13 9 16 3 14 4 20 15 5 15 42 40 35 36 22 37 39 38 25 41 26 30 27 28 29 33 31 32 ILLUSTRATED PARTS BREAKDOWN MODELS CD32M AND CD36M A SERIES ILLUSTRATED PARTS BREAKDOWN Models CD32M and CD36M A Series ...

Page 17: ...21 5 109405 01 103010 03 Left Top Log Log 5 1 21 6 109408 01 107348 01 Right Top Log Log 6 1 PARTS LIST MODELS CD32M AND CD36M A SERIES KEY PART NUMBER NO CD32M CD36M A DESCRIPTION QTY PARTS LIST Models CD32M and CD36M A Series Not a field replaceable part Optional See page 21 22 11102 11102 Screw 8 32 x 3 8 PPH Zinc 2 23 11105 11105 Screw 10 x 1 2 Zinc 9 24 11179 11179 Screw 10 24 x 1 4 Zinc 4 25...

Page 18: ...mation visit www desatech com 18 ILLUSTRATED PARTS BREAKDOWN MODEL CD42M A 37 23 41 42 38 22 39 32 31 33 28 26 25 29 24 34 35 40 36 30 27 28 6 7 19 18 10 12 2 11 17 8 20 1 4 13 16 3 14 15 5 15 9 212 21 3 21 6 21 7 21 5 21 4 21 1 ILLUSTRATED PARTS BREAKDOWN Model CD42M A ...

Page 19: ...398 01 Crossover Log Log 4 1 21 5 109399 01 Top Log Log 5 1 21 6 109400 01 Left Top Log Log 6 1 PARTS LIST MODEL CD42M A KEY PART NO NUMBER DESCRIPTION QTY 21 7 109401 02 Right Top Log Log 7 1 22 11102 Screw 8 32 x 3 8 PPH Zinc 2 23 11105 Screw 10 x 1 2 Zinc 9 24 11179 Screw 10 24 x 1 4 Zinc 4 25 11237 Screw Trilab M4 x 8mm 1 26 14389 HI LO Sit Valve Natural Gas 1 27 14492 Piezo Ignitor 1 28 14500...

Page 20: ...ifold Pressure 3 5 w c 3 5 w c 3 5 w c Minimum Inlet Supply Pressure 4 5 w c 4 5 w c 4 5 w c WIRING DIAGRAM Thermocouple Incoming Main Gas Supply Piezo Ignitor Control Valve Electrical Rating 120v 60Hz 0 7A Optional Wiring Diagram For Fan Kit Pilot TH TP TPTH Thermopile Piezo Ignitor Do Not Connect To 120V Remote Switch Supplied Safety Microswitch for Models CD32M 2 and CD36M A2 Only Pilot Gas Lin...

Page 21: ...1 CD36M SERIES 108455 01 CD42M 109479 01 CD32M SERIES BK BLOWER KIT REGULAR TRANSMITTER TRANSMITTER RECEIVER RECEIVER TRANSMITTER STANDARD REMOTE CONTROL KIT P N 14187 MILLIVOLT ONLY RECEIVER AND TRANSMITTER RECEIVER P N 00825 ELECTRONIC ONLY BATTERY REQUIRED FOR TRANSMITTER OPTIONAL REMOTE CONTROL KIT BATTERIES REQUIRED FOR PIEZO IGNITOR P N 14492 108085 01 51 NAT 108085 02 30 LP PILOT ORIFICE AN...

Page 22: ...For more information visit www desatech com For more information visit www desatech com 22 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 www desatech com NOT A UPC 111916 01 Rev A 08 03 111916 01 ...

Reviews: