Fixing clip
5
Disconnecting the indoor & outdoor unit
A
B
C
D
A. Electrical cable
B. Refrigerant tube
C. Drain tube
D. Refrigerant tube
If you need to disconnect the indoor unit from
the outdoor unit (to place it in a more suitable
position), please follow the steps below:
1. Open the tube connection box situated at
the back of the indoor unit. (FIG.12)
2. Disconnect the drain tube. (FIG.13)
3. Disconnect the electrical cable. (FIG.13)
4. Disconnect the refrigerant tubes using the
spanners provided.(fig.13). During this
operation, takes extreme care not to break
the refrigerant tubes.
5. Open the fixing clip above the tube
connection box.
6. Cap the terminals with provided caps to
prevent them from dust. (FIG. 14)
7. Mount the outdoor unit on the bracket as
previous described. 8. Pass the connecting
tube through the hole in the wall if present
(at least DIA. 50mm)
9 Remove the protection cap (If you have
capped them previously. Reconnect the
refrigerant tubes, drain tube and the
electrical cable in opposite steps. (FIG. 15)
10. Close the tube connection box. (FIG. 16)
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Warning!:
For safety reasons mounting and
dismounting of separate parts of the air
conditioner must be handled by a
qualified AC service worker. During the
dismounting, the refrigerant is likely to
evaporate and thus needs to be refilled .