background image

 

TECHNICAL DATA: 

 

ELECTRICAL RATINGS: 
Model Number 

Volts 

 

Amps  Frequency 

Watts 

9494800 

 

120V 

 

12A 

50 - 60Hz 

1200W 

9494801 

 

220-240V 

10A 

50 - 60Hz 

1200W 

9494900  

 

100V 

 

12A 

50 – 60Hz 

1200W 

DIMENSIONS:  

Length: 510mm 

(20.1”)  

Width:  366mm 

(14.4”) 

Height: 385mm 

(15.15”)

 

WEIGHT: 

120V:  25kg  (55 lbs) 
230V:  25kg  (55 lbs) 

OPERATING TEMPERATURE: 

5°C – 40°C   (41°F – 104°F) 

FUSE: 

Mains: F 250V 10A (2) – (230V only)   

ACCESSORIES:

 

9494800/900 
Bulb, Replacement (1 each) 

 

905032 

Filter (1 each) 

 

 

905034 

9494801 
Bulb, Replacement (1 each) 

 

905032 

Filter (1 each) 

 

 

905034 

10A Fuse (Mains – 230V only)  

9320069 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for ECLIPSE 9494800

Page 1: ......

Page 2: ...ervice the unit Do not operate the unit controls with tongs or other tool Do not use solvents or liquid cleaners on the control panel Do not touch the bulbs when the unit door is open Before replacing...

Page 3: ...60Hz 1200W DIMENSIONS Length 510mm 20 1 Width 366mm 14 4 Height 385mm 15 15 WEIGHT 120V 25kg 55 lbs 230V 25kg 55 lbs OPERATING TEMPERATURE 5 C 40 C 41 F 104 F FUSE Mains F 250V 10A 2 230V only ACCESSO...

Page 4: ...ining packing material on outside of unit Remove turntable from the top of unit Lift unit from packing supports by metal base only DO NOT LIFT UNIT USING PLASTIC SIDE COVERS Carefully place the unit o...

Page 5: ......

Page 6: ......

Page 7: ...displayed If a problem exists an error will be displayed Reference errors in the troubleshooting section of this manual INITIAL DIAGNOSTICS CHECK SCREEN DOOR MUST BE CLOSED After a successful diagnos...

Page 8: ...eturn automatically to the main menu A timer is displayed at the bottom of the screen indicating how much time is left to start the process To run this process the START STOP key must be pushed again...

Page 9: ...essed during a process the following screen is shown to confirm the aborting of the process ABORT PROCESS SCREEN ESC cancels the abort command ABORT PROCESS COOLING SCREEN If START STOP was pushed or...

Page 10: ...NERAL OPERATION Cont LOADING CARD PROGRAMS From this screen insert card with label facing up Press the PROG key to load data Program loading Program loaded remove card Display will return to Select Pr...

Page 11: ...exterior surfaces with a soft damp cloth using a mild detergent and water DO NOT IMMERSE IN WATER Clean the fan and exhaust vents using low pressure compressed air once a month or as needed to preven...

Page 12: ......

Page 13: ......

Page 14: ...urn the power switch OFF 2 Unplug the unit 3 Remove fuse drawer from inlet socket contains 2 fuses 4 Remove fuse drawer using small screwdriver to push on the locking clip 5 Replace fuse s with the F...

Page 15: ...e table down to the stop position Turn the unit ON Call DENTSPLY service department if problem persists OVER TEMPERATURE ERROR 2 The temperature of the unit has exceeded the maximum temperature allowe...

Page 16: ...DENTSPLY service department if problem persists POWER FAILURE AC line power was lost during a process Push ESC to return to the main menu CLOSE DOOR START STOP was pushed with the door open Once the d...

Page 17: ...ENTSPLY will not be responsible for damages resulting from improper packing Ship prepaid to DENTSPLY Prosthetics ATTN Equipment Repair PR Number__________________ 470 West College Ave York PA 17401 US...

Page 18: ......

Page 19: ...___________________________ _________________________________________________________________________ _________________________________________________________________________ ________________________...

Page 20: ...n this time period shall be deemed to be a waiver of such claim DISCLAIMER The provisions here in stated DENTSPLY Prosthetics sole obligation and exclude all other remedies or warranties expressed or...

Reviews: