1 General data
1.4 Warranty and liability
Dentsply Sirona
Operating Instructions for suction devices
6
66 25 540 D3608
D3608.201.02.05.02 10.2020
1.4
Warranty and liability
Maintenance
In the interest of the safety and health of users or third parties, it is
necessary that maintenance work is carried out at fixed time intervals to
ensure the operational safety and reliability of your product.
The operator must ensure the implementation of the maintenance work.
As a manufacturer of electro-medical equipment, we can consider
ourselves responsible for the safety characteristics of the device only if
maintenance and repairs are carried out only by us or by companies
authorized explicitly by us for this purpose and if components are
replaced with original spare parts in case of failure.
Exclusion of liability
If the operator does not meet the obligation to carry out such
maintenance or fault messages are ignored, Sirona Dental Systems or
its authorized dealer does not assume any liability for damage caused.
1.5
Intended use
The suction system is used to extract dry, non-explosive dusts and
chips that emerge when processing various materials for the production
of dental aids and technologies and dentures. The suction system may
only be operated indoors. The suction system must not be used for any
other purpose.
This unit must not be used for any other purpose. If the unit is used for
any purpose other than the one mentioned above, it may be damaged.
Intended use also includes compliance with these Operating
Instructions and the relevant maintenance instructions.
CAUTION
Follow the instructions
If the instructions for operating the unit described in this document are
not observed, the intended protection of the user may be impaired.
CAUTION
Dry processing
In the event of dry processing without suction, dust can be created
from the materials being processed. Breathing in this dust can have
associated health risks.
➢ As such, observe the information and requirements of the suction.
➢ Dry processing is only permissible in conjunction with the CEREC
suction device 230 V or 120 V.
- CEREC suction device 230 V / 120 V, ordered together with the
device: REF 6569730
- CEREC suction device 230 V/120 V, if ordered separately: REF
6580786
Summary of Contents for 6385129
Page 2: ......
Page 29: ......
Page 87: ......
Page 89: ...10 2020 inLab MC X5 CEREC Primemill CEREC MC MC X MC XL Premium Package...
Page 96: ...1 1 6 Dentsply Sirona 8 66 25 540 D3608 D3608 201 02 05 12 10 2020 1 6 20XX 28...
Page 111: ...Dentsply Sirona 6 6 2 66 25 540 D3608 D3608 201 02 05 12 10 2020 23 5 6 HEPA 7 8 9 6 2 800...
Page 114: ...7 7 1 Dentsply Sirona 26 66 25 540 D3608 D3608 201 02 05 12 10 2020 7 7 1 HEPA HEPA...
Page 115: ...Dentsply Sirona 7 7 2 66 25 540 D3608 D3608 201 02 05 12 10 2020 27 7 2 14 HEPA HEPA HEPA HEPA...
Page 119: ...10 2020 inLab MC X5 CEREC Primemill CEREC MC MC X MC XL Premium Package...
Page 125: ...Dentsply Sirona 1 1 6 66 25 540 D3608 D3608 201 02 05 27 10 2020 7 1 6 20XX 26...
Page 126: ...1 1 6 Dentsply Sirona 8 66 25 540 D3608 D3608 201 02 05 27 10 2020...
Page 142: ...7 7 1 Dentsply Sirona 24 66 25 540 D3608 D3608 201 02 05 27 10 2020 7 7 1 On min max HEPA HEPA...
Page 147: ......