![Denso Keyence Vision XG Series Manual Download Page 32](http://html.mh-extra.com/html/denso/keyence-vision-xg-series/keyence-vision-xg-series_manual_2483252032.webp)
32
画像処理システム/XGシリーズ
6. Error Code of XG provider
The specific error code of XG provider is created as shown below, based on the return value of XG.
0x80 Return value
For the error code of each command, refer to ActiveX control reference manual of Keyence.
Example: When executing
ChangeMode.
0x801003EA: Parameter value is out of range.
The following error codes are defined as original error codes.
Error
Error number
Description
E_BASED_VWXG
0x80100000
VWXG series original error
E_ENABLED_CANCEL
0x80101000
Failed to perform cancel process
E_EXECUTING
0x80102000
Another command was executed during a command
execution
E_GET_COMMAND_RESULT
0x80103000
GetCommandResultcommand was executed after a
Synchronous command execution
About the ORiN2 commonness error, please refer to the chapter of the error code of "ORiN2 Programming guide".