![Denso Keyence Vision XG Series Manual Download Page 23](http://html.mh-extra.com/html/denso/keyence-vision-xg-series/keyence-vision-xg-series_manual_2483252023.webp)
23
画像処理システム/XGシリーズ
<ImplVar>
.ChangeInspectSetting
Usage
Changes the setting to the inspection setting number of the specified SD card.
Syntax
<ImplVar>
.ChangeInspectSetting
<
SD card number>, <
Inspection
setting number>
Argument: <
SD card number> Specify the SD card number (Integer 1, 2).
<
Inspection setting number> Specify the inspection setting number
(Integer 0 to 999)
Description
The setting is changed to the inspection setting number of the specified SD card.
Example
Dim caoCtrl as Object
caoCtrl=cao.AddController("XG","CaoProv.KEYENCE.VWXG", "", "conn=eth:192.168.0.10")
caoCtrl.ChangeInspectSetting 1, 2