![Denso Keyence Vision XG Series Manual Download Page 11](http://html.mh-extra.com/html/denso/keyence-vision-xg-series/keyence-vision-xg-series_manual_2483252011.webp)
11
画像処理システム/XGシリーズ
cao.AddController
Usage
Implements the provider to a variable and makes a connection to XG.
Syntax
cao.AddController(
<Controller name>,<Provider name>,
<Provider running machine name>,<Option>
)
Argument:
<Controller name> Assign a name (The name is used for control).
<Provider name> "CaoProv.KEYENCE.VWXG"
<Provider running machine name> Omit this parameter.
<Option> [Connection parameter]
[Connection parameter] "conn=eth:<IP address>[:Port number]"
Default port number is 8502.
(The port number is optional.)
[Timeout period] Specify the timeout period (msec) for transmission.
"Timeout[=<Time>]" Default : 500
(The timeout period is optional.)
Description
The provider becomes effective when implemented to a variable. From this point the
implemented Object type variable is used to access the provider. (The implemented
variable is called "Implementation Variable".
)
Example
Dim caoCtrl as Object
caoCtrl=cao.AddController("XG","CaoProv.KEYENCE.VWXG", "", "conn=eth:192.168.0.10")
* Specify a port number as follows: