Summary of Contents for Solar Amp BG

Page 1: ...t safety installation and operating instructions for SolarAmp BG solar charge controller in order to prevent the users from any damage Make sure to read all of the instructions and cautions in the man...

Page 2: ...ernal fuses less than rated current between controller and battery controller and load Connect battery to earth ground if necessary positive earth ground If you need negative earth ground connect only...

Page 3: ...5 Safety Information 5 1 DO NOT short circuit For all terminals 5 2 Explosion hazard 5 3 Keep out of direct sunlight 5 4 Positive earth ground 5 5 DO NOT reverse polarity connection For all terminals...

Page 4: ...6 Connection Connect each wire in order 1 LOAD 2 BATTERY 3 PV panel as the figure below Please use the proper size wire and connector Red Blue Red Black Red White...

Page 5: ...7 Appearance Unit mm Mounting holes...

Page 6: ...d Float Charging Yellow 1 blink Low Voltage Warning 2 blinks High Temperature Warning Blinks Over Load Reconnecting Green Yellow 1 1 blinks Charging Low Voltage Warning 1 2 blinks Charging High Temper...

Page 7: ...g Voltage 14 4Vdc Float Charging Voltage 13 7Vdc High Voltage Protection 18Vdc Over Discharge Protection Warning 11 8Vdc Error 11 5Vdc Recovery 12 5Vdc High Temperature Protection Warning 60 C Error 8...

Page 8: ...DM 5202 DENRYO CO LTD 28 5 Nishinippori 2 Chome Arakawa ku Tokyo 116 0013 Japan TEL 81 3 3802 3671 FAX 81 3 3802 2974 Email info en denryo com Website www denryo com...