background image

3. Features 

Waterproof and dustproof (IP68) 

NOTE: This does not guarantee no damage, no breakdown, or waterproof and dust 
proof performance in all conditions. 

3-stage Charging (Bulk, Absorption, Float) 

Discharged Battery Recovery 

Full Electronic Protections 

High / Low Voltage Protection, Over Discharge Protection, Over Load Protection, 
High Temperature Protection, Reverse Polarity Protection, 
Load Short Circuit Protection, Surge Protection 

Current Regulation Caused High Temperature

 

Positive Earth Ground

 

Status LED Indications

 

State of Charging, High / Low Voltage, Over Load, High Temperature 

 

4. Precaution 

Cover the PV panel (Photovoltaic panel: Solar panel) with cloth not to 

generate electricity during installation. 

It is recommended to install an external fuses (less than rated current) 

between controller and battery, controller and load. 

Connect battery to earth ground if necessary (positive earth ground). If 

you need negative earth ground, connect only one terminal (battery or 

PV panel or load terminal) to the earth ground.

 

Do not connect device which has large input capacitance such as DC-

AC inverter to the load terminal.

 

Do not use PV panel or Load of which specification is out of the ratings. 

The PV panel Voc should never exceed ”Max. Input Voltage” of the controller. 
The PV panel Isc should never exceed ”Max. Input Current” of the controller. 

The Peak current of load should never exceed ”Max. Load Current” of the controller. 

Charging will start when PV panel voltage exceeds battery voltage. 

Reverse Polarity Protection and Over Load Protection is not effective in 

every possible condition, thus please take care when wiring and 

confirm the specifications of PV panel and battery and load.

 

Summary of Contents for Solar Amp BG

Page 1: ...t safety installation and operating instructions for SolarAmp BG solar charge controller in order to prevent the users from any damage Make sure to read all of the instructions and cautions in the man...

Page 2: ...ernal fuses less than rated current between controller and battery controller and load Connect battery to earth ground if necessary positive earth ground If you need negative earth ground connect only...

Page 3: ...5 Safety Information 5 1 DO NOT short circuit For all terminals 5 2 Explosion hazard 5 3 Keep out of direct sunlight 5 4 Positive earth ground 5 5 DO NOT reverse polarity connection For all terminals...

Page 4: ...6 Connection Connect each wire in order 1 LOAD 2 BATTERY 3 PV panel as the figure below Please use the proper size wire and connector Red Blue Red Black Red White...

Page 5: ...7 Appearance Unit mm Mounting holes...

Page 6: ...d Float Charging Yellow 1 blink Low Voltage Warning 2 blinks High Temperature Warning Blinks Over Load Reconnecting Green Yellow 1 1 blinks Charging Low Voltage Warning 1 2 blinks Charging High Temper...

Page 7: ...g Voltage 14 4Vdc Float Charging Voltage 13 7Vdc High Voltage Protection 18Vdc Over Discharge Protection Warning 11 8Vdc Error 11 5Vdc Recovery 12 5Vdc High Temperature Protection Warning 60 C Error 8...

Page 8: ...DM 5202 DENRYO CO LTD 28 5 Nishinippori 2 Chome Arakawa ku Tokyo 116 0013 Japan TEL 81 3 3802 3671 FAX 81 3 3802 2974 Email info en denryo com Website www denryo com...