3-13. Error Code H1-16 failure detection procedure
Check the power supply voltage. (ARC IC)
Check item(3-13.1.).
Check the power supply voltage. :
Does the power supply voltage of the ARC IC [
U3802
] indicate the correct voltage (1.2V)?
The test points are as follows.
N3401
HDMI OUT
[MONITOR2]
L3805
1.2V
Check item(3-13.2.).
Check the power supply voltage. :
Check the power components [
U3801
] and the pattern on the sub-
strate.
If there is no problem, remove the ARC IC [
U3802
] from the sub-
strate and measure the voltage at the test point of
check item (3-
13.1.)
.
Is the power supply voltage correct (1.2V)?
Replace with a new device.
The power supply circuit is
faulty.
Replace the PCB.
Recheck from
check item (3.1.)
If it does not work, replace the PCB.
Checking device. [
U3802 : SiI9437
]
NO
YES
NO
YES
YES
Checking the reset waveform. (ARC IC)
Check item(3-13.3.).
Checking the reset waveform :
Check the waveform.
Is the "
RESET
" waveform of the ARC IC [
U3802
] correct (like the
one shown in the diagram) when the power is turned on?
N3402
HDMI OUT
[MONITOR1]
U3802
R3805 : RESET
Check the reset circuit between
CPU [
U6201
] and ARC IC [
U3802
].
If there is no problem, the ARC IC
[
U3802
] is faulty.
Replace with a new device.
NO
Examples of confirmation waveform
Voltage scale : 1.0V/div
Time scale : 20ms/div
ARC IC [
U3802
] is faulty.
Replace with a new device.
Recheck from
check item (3.1.)
If it does not work, replace the PCB.
Before Servicing
This Unit
Electrical
Mechanical
Repair Information
Updating
117